P.K. Wadsworth Heating & Cooling has striven to give our clients the best heating, AC, and water heater services available since 1936. Since then, we’ve earned over 32,000 five-star reviews from our residential and commercial clients. When your home systems give you trouble, we’ll be there to help so you can spend your time keeping your business running or enjoying all our beautiful city has to offer, including Liberty Park and Blue Hen Falls.
Contact P.K. Wadsworth Heating & Cooling for dependable HVAC and water heater solutions in Twinsburg, OH.

Reliable AC & Cooling Services
When the temperature rises, having AC you can count on is critical. A home without air conditioning is left open to an overload of contaminants, putting indoor air quality at risk. We offer various cooling services to keep your air conditioner running, including installation, replacement, repair, and maintenance. Our knowledgeable technicians can handle multiple systems, including:
- Ductless mini-splits: These modern options are a fantastic solution for homes that lack the ductwork a traditional AC system requires. They can also be combined with other AC types to improve energy efficiency.
- Heat pumps: You can combine heating and cooling into one with a heat pump, which offers lower-cost solutions for maintaining your home’s temperature.
Thorough Heating Repair & Replacement
Heat is crucial to the health and comfort of your home as Twinsburg temperatures drop. Our expert heating technicians are trained in various heating services, including replacement, installation, maintenance, and repair. We have decades of knowledge and are capable of handling multiple systems like:
- Furnaces: Whether you’re having issues with your pilot light or the unit isn’t hot enough, we can fix your gas, electric, or oil furnace.
- Boilers: These units offer dual capabilities of heating your home and providing hot water.
Indoor Air Quality Services in Twinsburg
The condition of your indoor air influences every area of your life. If it’s unhealthy, so are you. This is why we supply the best indoor air quality services available.
- Air purifiers: Systems like HEPA filters rid the air in your home of debris, pet dander, and other contaminants, lessening the load on your respiratory system.
- Air scrubbers: These units remove mold, pollen, odors, and germs, allowing your loved ones to breathe more easily.
- Humidifiers: Air craves moisture, and when it’s too dry, it’ll take it from any source, including you and your furniture. Using a humidifier helps balance humidity levels and protect your home and body.
- Dehumidifiers: When the air is too humid, mildew and mold grow in walls, risking damage to wooden structures. Dehumidifiers help protect your home by ridding it of excess moisture.
Top-Rated Water Heater & Plumbing Services
A working plumbing system is a cornerstone of a modern home, and hot water is key in multiple areas of life, including hygiene and cooking. We offer expert plumbing services to keep your pipes and water-based appliances running smoothly, such as:
- Water heater services: Whether you’re experiencing no hot water or some other issue, our expert plumbing technicians can fix it.
- Tankless water heater services: When sized to your needs, these units offer several benefits, including endless hot water. If you want to add a tankless water heater to your life, our knowledgeable technicians will be happy to walk you through the options.
Schedule With P.K. Wadsworth Heating & Cooling In Twinsburg Today
With over eight decades in business, P.K. Wadsworth Heating & Cooling understands the Twinsburg area. We’re family-operated and passionate about delivering reliable services on time. We keep our estimates free and our pricing upfront and instant, so there are no nasty surprises. To help take the headache out of maintaining your home systems, we offer same-day services and maintenance plans.
For professional home services in the Twinsburg area, schedule an appointment with P.K. Wadsworth Heating & Cooling today!
P.K. Wadsworth Heating, Cooling, Plumbing and Electric has completed 20 jobs in Twinsburg, OH between September 2026 and October 2026. The most recent job was on October 1, 2026. P.K. Wadsworth Heating, Cooling, Plumbing and Electric has completed 312 jobs in Twinsburg, OH in the last 12 months.Recent Jobs and Reviews in Twinsburg, OH
Twinsburg, OH at a glance
Job Locations and Reviews
Performed routine maintenance flush and descale service on tankless water heater unit. Isolated unit using existing shut-off valves, connected descaling pump with hoses to service ports, and circulated manufacturer-recommended descaling solution through the heat exchanger to remove mineral buildup and scale deposits. Flushed system thoroughly with clean water, restored unit to normal operation, and verified proper function of all components including gas line connections, copper supply lines, venting system, and digital control panel.
Completed comprehensive cooling system maintenance on HVAC unit. Inspected evaporator coil and filter assembly, which showed moderate dust accumulation in upper section requiring attention. Verified system operation with supply air temperature reading of 18.3°F, confirming proper refrigerant charge and cooling performance. Checked refrigerant line connections and humidifier control panel for proper operation.
Responded to emergency plumbing service call for leaking pipe after original appointment cancellation. Upon inspection, identified water leak in PVC plumbing system located within ceiling cavity between floor joists. Assessed condition of white PVC supply lines with purple markings and adjacent copper piping with elbow joint fittings. Documented existing infrastructure including wooden structural members, OSB sheathing, and fiberglass insulation for repair planning and successfully resolved the leak issue.
Performed comprehensive heating system maintenance on HVAC unit. Conducted thorough inspection of internal components including circuit board, electrical connections, wire harnesses, and blower assembly with access panel removed. Performed combustion analysis testing using calibrated analyzer, recording readings of 61°F and 28 ppm to verify proper system operation and combustion efficiency. All components found operating within normal parameters and unit returned to service.
Completed scheduled preventive maintenance on residential cooling system. Performed comprehensive inspection of indoor air handler unit, verified proper airflow through clean air filter, and examined all accessible ductwork connections for secure installation. Inspected furnace cabinet, refrigerant lines with shut-off valves, condensate drainage system, and electrical connections to ensure system integrity and optimal operational readiness for continued service.
Completed scheduled preventive maintenance on residential heating system. Performed temperature diagnostics at supply register measuring 97.1°F and at furnace test port measuring 73°F, confirming proper heat rise and system operation within manufacturer specifications.
Completed scheduled heating maintenance on residential furnace system located in attic installation. Performed comprehensive inspection of air handler unit, evaporator coil assembly, and all electrical connections. Verified proper operation of blower motor, checked filter condition, and confirmed all safety controls and limit switches were functioning within manufacturer specifications.
# HVAC Cooling System Maintenance Completed
Performed routine preventive maintenance on residential air conditioning system as part of ongoing maintenance program. Conducted comprehensive inspection of cooling equipment including air handler unit and associated components. Inspected and verified proper installation of pleated air filter (20x25x8) in return air system, confirming adequate airflow and filtration. Examined ductwork for dust accumulation and general condition. Performed diagnostic measurements using digital testing equipment to verify system performance parameters. Inspected electrical connections and control wiring for proper operation. All components found operating within normal specifications with no immediate service needs identified.
Responded to complaint of sewer odor in first-floor half bathroom following recent renovation. Inspected toilet installation and confirmed improper wax ring seal was causing odor infiltration. Removed toilet, replaced faulty wax ring with proper-sized wax seal, reset toilet to flange, and verified proper seal with leak test. Sewer odor issue resolved.
Completed routine cooling system maintenance on HVAC air handler unit. Accessed evaporator coil compartment and inspected finned heat exchanger for cleanliness and proper condition. Verified foil-faced insulation integrity within unit housing. Replaced air filter with new pleated filter and confirmed proper fitment in return air assembly. Inspected ductwork connections and internal components for normal operation. All system components found in satisfactory working condition with no issues identified.
# HVAC Heating Maintenance Service
Completed routine heating maintenance on gas furnace as part of ongoing service plan. Inspected heat exchanger and burner assembly, noting significant rust and corrosion on heat exchanger chambers with active blue flames present at burner ports indicating proper combustion. Documented system condition with photos showing deteriorated metal surfaces and operational burner assembly for maintenance records and future reference.
Responded to emergency no-water call at 1989-construction residence with failed original plumbing infrastructure. Inspected main water shutoff valve in basement and identified severely corroded brass valve with compromised seating and aged copper supply line showing significant oxidation. Documented existing PVC distribution piping with access point through interior wall cavity, revealing aged coupling connections. Due to emergency nature of complete water loss, prioritized immediate assessment and coordinated with customer regarding urgency of restoration timeline and available repair options for failed main shutoff assembly.
Conducted comprehensive electrical estimate for backup generator installation at residential property. Assessed existing electrical panel configuration, circuit capacity, and required modifications for generator integration, including evaluation of transfer switch placement and necessary wiring routes through unfinished interior spaces. Documented current electrical infrastructure, outdoor installation area near elevated deck structure, and optimal generator positioning to ensure proper clearances from building structures and landscaping features while maintaining code compliance and accessibility for future maintenance.
Responded to callback for 1-year-old Amana furnace continuing to run with thermostat in off position following previous day's maintenance visit. Inspected thermostat wiring, control board connections, and furnace operation sequence. Verified supply air temperature at 57.2°F during diagnostic testing and confirmed proper system cycling after adjustments.
Responded to service call for active water leak originating from furnace blower area in basement. Upon inspection, discovered significant condensate drainage issue caused by corroded evaporator coil and accumulated debris within the ductwork system. The 5-year-old furnace unit exhibited extensive rust staining across the evaporator coil surface, indicating prolonged moisture exposure and inadequate drainage. Interior ductwork inspection revealed heavy dust accumulation, mineral deposits on metal surfaces, and rust-colored staining along bottom seams where water had been pooling. Documented corroded coil condition and contaminated ductwork with photographic evidence for service records. Identified primary cause as compromised coil integrity combined with blocked or insufficient condensate drainage system, resulting in water overflow onto basement floor.
Completed scheduled maintenance visit on residential HVAC system including both outdoor condensing unit and indoor air handler components. Performed comprehensive inspection of exterior condenser unit, verified proper operation of compressor and condenser fan motor, checked electrical connections at disconnect box, and confirmed adequate airflow through coil louvers. Inspected indoor furnace assembly including blower motor operation, control board functionality, electrical connections, and air filter condition, documenting system status with photographs for service records.
Completed scheduled heating maintenance on 11-year-old Ruud system that had missed its summer check. Performed comprehensive tune-up including system diagnostics, airflow measurements at supply registers (recorded 1382 CFM), visual inspection of all accessible components, and verification of proper operation. System is functioning within normal parameters and ready for the heating season.
Returned to property to replace evaporator coil in air handler unit located in interior mechanical space. Removed old coil, installed new replacement coil, and pressure-tested system for leaks. Evacuated system to proper vacuum levels, then recharged unit with refrigerant to manufacturer specifications using manifold gauges and verified proper operating pressures and temperatures upon completion.
Completed semi-annual heating maintenance on Lennox furnace in preparation for fall/winter season. Performed comprehensive system inspection including verification of all mechanical components, air flow measurements, and temperature diagnostics. Checked heat exchanger integrity, tested ignition system operation, inspected burner assembly and flame sensor, verified proper venting and combustion air supply, examined blower motor and capacitor function, and confirmed thermostat calibration. Measured supply air temperatures and assessed ductwork connections for proper sealing. Replaced air filter and cleaned blower compartment. All safety controls tested and operating within manufacturer specifications. System cycled properly with no abnormalities detected. Furnace operating efficiently and ready for heating season demand.
Completed comprehensive cooling system maintenance on HVAC unit. Performed standard diagnostics using digital testing equipment to verify system performance and operational parameters. Inspected and evaluated air filtration system, noting clean pleated filter in proper working condition within mounting frame. All components assessed and found to be functioning within normal specifications.