Reliable heating, air conditioning, and water heater services are essential for maintaining the health and comfort of both residential and commercial spaces. P.K. Wadsworth Heating & Cooling has been serving the resilient community of Cleveland for over 85 years, providing top-notch services to ensure these systems function efficiently.
Whether you’re a home or business owner, having economical heating and cooling systems is critical, especially when you would rather be enjoying a Cleveland Browns game or visiting The Cleveland Museum of Art. Our goal is to get your HVAC systems and water heater up and running so you can focus on what matters most.
Contact P.K. Wadsworth Heating & Cooling today for reliable HVAC, plumbing, and water heater services in Cleveland, OH.

Air Conditioning & Cooling Services
When temperatures rise, having a dependable air conditioning system is vital. We offer a wide range of cooling services to keep you comfortable.
- Installation and replacement: We can remove your old unit and install the new one, ensuring optimal performance.
- Repair and maintenance: Our expert technicians are available for repairs and regular maintenance to keep your AC running smoothly.
- Ductless mini-splits: Ideal for residences without ductwork, these systems offer flexible and efficient cooling solutions.
- Heat pumps: These versatile systems provide heating and cooling, offering year-round comfort.
Same-Day Heating Repair & Replacement Services
A functioning heating system is crucial to keep you warm during Cleveland’s cold months, which can reach the mid-20s. Our comprehensive heating services include:
- Installation and replacement: We install and replace heating systems, ensuring they meet your needs and preferences.
- Repair and maintenance: Our skilled technicians perform repairs and maintenance to keep your heating system operating effectively.
- Gas, electric, and oil furnaces: We service various types of furnaces to provide reliable and efficient heating solutions.
- Boilers: Our boiler experts specialize in installation, replacement, repair, and maintenance to ensure consistent warmth throughout your home.
Indoor Air Quality Services in Cleveland
Indoor air quality affects every aspect of our lives, especially for individuals with lung conditions like asthma. We offer several air quality services to ensure the best air quality in your home.
- Air purifiers: These devices remove contaminants from the air, providing a cleaner and healthier environment.
- Air scrubbers: Air scrubbers reduce airborne particles and pollutants, improving indoor air quality.
- Humidifiers: Adding moisture to the air, humidifiers help alleviate dry air problems and enhance comfort.
- Dehumidifiers: These systems remove excess moisture, preventing mold growth and maintaining a comfortable indoor climate.
Top-Rated Water Heater & Plumbing Services
When your water heater begins to struggle, it can be a hassle, with water damage spreading quickly in some cases. Our knowledgeable team of technicians provides a range of plumbing services, including but not limited to:
- Installation and repair
- Water heaters and tankless water heaters
- Expansion tank services
- Leak detection
- Drain cleaning
- Gas line plumbing
- Sump and well pump services
Choose P.K. Wadsworth Heating & Cooling in Cleveland, OH
P.K. Wadsworth Heating & Cooling has been a leading name in the home service industry for over 85 years. As a family-owned and -operated business, we provide exceptional service with trained and certified technicians. Our team is known for being on-time and reliable, offering same-day services and maintenance plans to keep your systems in top condition. With over 32,000 five-star reviews from satisfied customers, you can trust us for all your HVAC and plumbing needs. We offer upfront and instant pricing, ensuring no hidden costs.
Schedule service with P.K. Wadsworth Heating & Cooling today for top-rated HVAC, water heater, and plumbing services in Cleveland, OH.
Recent Jobs and Reviews in Cleveland, OH
Job Locations and Reviews
Completed scheduled cooling system maintenance visit. Performed comprehensive inspection of air conditioning unit, including temperature differential measurements at supply registers and thorough examination of evaporator coil assembly. Coil fins found in good condition with minimal debris accumulation. All system components operating within normal parameters.
Responded to air conditioning unit leaking water into basement. Upon inspection, found condensate drainage system with safety float switch installed on P-trap assembly. Verified proper operation of condensate pump and drainage lines. Inspected outdoor condensing unit components including capacitor, compressor diagnostics module, and electrical connections. System tested and confirmed operational with no active leaks observed during runtime.
Completed installation of new air conditioning system integrated with existing Trane XR95 furnace. Installed and configured outdoor condensing unit, refrigerant lines, and electrical connections. Verified system operation with digital multimeter readings showing proper voltage at 66.4V, confirming electrical components functioning within manufacturer specifications. Routed and secured all necessary condensate drain lines and refrigerant piping, ensuring proper airflow through existing ductwork and plenum assembly.
Completed scheduled preventive maintenance on residential air conditioning system. Performed comprehensive inspection of electrical components including capacitor, contactor, and associated wiring connections. Verified proper electrical readings using digital clamp meter, confirming system operating within normal parameters at 0.00 amp draw during testing phase. All electrical connections secure, capacitor functioning properly, and unit ready for continued cooling operation.
Conducted residential HVAC estimate for furnace replacement at property with existing Bryant brand unit installed in basement mechanical room. Documented current system configuration including ductwork connections, electrical components, and associated air handler equipment. Photographed existing installation to provide homeowner with replacement options and system upgrade recommendations.
Replaced defective pressure relief valve on residential boiler system. Removed old valve, installed new NIBCO brass pressure relief valve with proper threaded connections, and verified all copper supply line connections were secure and leak-free. System tested and confirmed operating safely within normal pressure parameters.
Responded to service call for HVAC system maintenance. Found existing air filters heavily soiled with accumulated dirt, dust, and airborne contaminants, significantly restricting airflow and reducing system efficiency. Installed filter upgrade box to improve filtration performance and extend filter service life.
Responded to service call for Envirotemp tanked water heater experiencing internal tank leak causing pilot flame extinguishment. Upon inspection, confirmed water leakage from inside the tank contaminating the burner assembly and preventing proper ignition. Unit determined to be beyond economical repair due to compromised tank integrity requiring full replacement.
Completed scheduled preventive maintenance on residential split-system air conditioning unit. Performed comprehensive inspection of rooftop condenser unit and indoor air handler/furnace system. Checked refrigerant lines, electrical connections, and overall system operation. All components found to be functioning within normal parameters. Discussed customer inquiry regarding conversion of existing wireless thermostat to hardwired configuration for improved reliability and system integration.
# HVAC Cooling Maintenance Completed
Performed comprehensive cooling system maintenance on residential HVAC unit. Conducted electrical diagnostics using digital clamp meter to verify proper amperage draw and voltage levels across system components. Measured current flow on compressor circuit, confirming readings within manufacturer specifications at 0.54 amps on control circuit. Inspected and tested low-voltage control wiring, including thermostat connections with multiple conductor bundle showing proper color coding and secure terminations. Verified electrical panel connections and control board functionality. All voltage readings confirmed within acceptable CAT IV 600V parameters. System tested and operating normally with proper electrical values throughout cooling cycle.
Completed contract cooling tune-up on residential Airtemp furnace system. During inspection, discovered severe frost accumulation on supply ductwork in attic space, with surface temperature measuring 51.6°F, indicating significant airflow restriction or refrigerant issue affecting cooling performance. Documented equipment condition and duct frost buildup for further diagnostic evaluation and necessary repairs to restore proper system operation.
Completed comprehensive cooling tune-up on Ameristar residential air conditioning system. Performed visual inspection of condenser unit, verified proper operation of all components, and inspected heat exchanger coils which were found to be in clean, well-maintained condition with no blockages or deterioration noted.
Completed comprehensive cooling system tune-up on residential HVAC unit. Performed diagnostic testing using digital multimeter to verify electrical readings and system performance, inspected compressor operation with CoreSense diagnostic tool, and checked refrigerant pressures with manifold gauges. All components operating within normal parameters, capacitor date verified, and system confirmed ready for continued service.
Completed installation of ductless mini-split HVAC system including electrical infrastructure setup. Installed sub panel and dedicated circuit to support the new system, mounted interior wall unit in conditioned space, and positioned Daikin outdoor condenser unit on exterior of residence. All electrical work, refrigerant lines, and system components were installed and commissioned on the same day for immediate operation.
Installed new Siemens sub panel and circuit breaker system with 15 amp maximum capacity rated at 11.1 minimum amps. Completed full electrical panel installation including proper circuit breaker arrangement, wire routing, and ground bar connections with appropriate color-coded wiring throughout the enclosure. All circuits were properly labeled for identification, including A/C condenser and other designated loads, and the panel was mounted on plywood backing with all connections secured to code specifications.
Completed full HVAC system installation including 96% efficiency furnace, air conditioning unit, and S-Series RTU package. Performed comprehensive electrical connections, verified all wiring configurations, tested system components with digital multimeter to ensure proper voltage and functionality, and confirmed successful operation of complete heating and cooling system.
Completed scheduled preventive maintenance on residential cooling system. Performed comprehensive inspection of HVAC equipment including ductwork temperature verification in attic space, recording supply air temperature at 70.3°F, and confirmed proper airflow through return air grille with clean filter media and unobstructed louvers. All system components operating within normal parameters with no deficiencies noted.
Completed preventive maintenance inspection on Carrier HVAC system. Performed standard cooling season checkup including system diagnostics and temperature readings within the air handler unit, which measured 155°F at the time of inspection. Verified proper operation of furnace and associated equipment, inspected PVC venting system for proper configuration, and ensured all components were functioning correctly for the upcoming cooling season.
Responded to service call for air conditioning unit leaking water. Upon inspection, discovered severely corroded evaporator coil with significant rust and oxidation throughout the heat exchanger assembly. The coil showed advanced deterioration consistent with age and prolonged moisture exposure, which was the source of the water leak. Identified compromised condensate drainage system with PVC drain line showing signs of improper pitch or blockage contributing to water backup. Documented existing conditions with photographs showing extent of corrosion on copper tubing, fins, and internal components. Advised customer that the evaporator coil has reached end of serviceable life and requires replacement to resolve the leak issue permanently. Discussed options for repair versus system replacement given the advanced age and condition of the equipment.
Conducted on-site assessment for complete HVAC system replacement in commercial building with interior stairwell access. Evaluated existing ductwork configuration in ceiling area and documented measurements of access points to determine equipment specifications and installation requirements for full system upgrade.