Reliable heating, air conditioning, and water heater services are essential for maintaining the health and comfort of both residential and commercial spaces. P.K. Wadsworth Heating & Cooling has been serving the resilient community of Cleveland for over 85 years, providing top-notch services to ensure these systems function efficiently.
Whether you’re a home or business owner, having economical heating and cooling systems is critical, especially when you would rather be enjoying a Cleveland Browns game or visiting The Cleveland Museum of Art. Our goal is to get your HVAC systems and water heater up and running so you can focus on what matters most.
Contact P.K. Wadsworth Heating & Cooling today for reliable HVAC, plumbing, and water heater services in Cleveland, OH.

Air Conditioning & Cooling Services
When temperatures rise, having a dependable air conditioning system is vital. We offer a wide range of cooling services to keep you comfortable.
- Installation and replacement: We can remove your old unit and install the new one, ensuring optimal performance.
- Repair and maintenance: Our expert technicians are available for repairs and regular maintenance to keep your AC running smoothly.
- Ductless mini-splits: Ideal for residences without ductwork, these systems offer flexible and efficient cooling solutions.
- Heat pumps: These versatile systems provide heating and cooling, offering year-round comfort.
Same-Day Heating Repair & Replacement Services
A functioning heating system is crucial to keep you warm during Cleveland’s cold months, which can reach the mid-20s. Our comprehensive heating services include:
- Installation and replacement: We install and replace heating systems, ensuring they meet your needs and preferences.
- Repair and maintenance: Our skilled technicians perform repairs and maintenance to keep your heating system operating effectively.
- Gas, electric, and oil furnaces: We service various types of furnaces to provide reliable and efficient heating solutions.
- Boilers: Our boiler experts specialize in installation, replacement, repair, and maintenance to ensure consistent warmth throughout your home.
Indoor Air Quality Services in Cleveland
Indoor air quality affects every aspect of our lives, especially for individuals with lung conditions like asthma. We offer several air quality services to ensure the best air quality in your home.
- Air purifiers: These devices remove contaminants from the air, providing a cleaner and healthier environment.
- Air scrubbers: Air scrubbers reduce airborne particles and pollutants, improving indoor air quality.
- Humidifiers: Adding moisture to the air, humidifiers help alleviate dry air problems and enhance comfort.
- Dehumidifiers: These systems remove excess moisture, preventing mold growth and maintaining a comfortable indoor climate.
Top-Rated Water Heater & Plumbing Services
When your water heater begins to struggle, it can be a hassle, with water damage spreading quickly in some cases. Our knowledgeable team of technicians provides a range of plumbing services, including but not limited to:
- Installation and repair
- Water heaters and tankless water heaters
- Expansion tank services
- Leak detection
- Drain cleaning
- Gas line plumbing
- Sump and well pump services
Choose P.K. Wadsworth Heating & Cooling in Cleveland, OH
P.K. Wadsworth Heating & Cooling has been a leading name in the home service industry for over 85 years. As a family-owned and -operated business, we provide exceptional service with trained and certified technicians. Our team is known for being on-time and reliable, offering same-day services and maintenance plans to keep your systems in top condition. With over 32,000 five-star reviews from satisfied customers, you can trust us for all your HVAC and plumbing needs. We offer upfront and instant pricing, ensuring no hidden costs.
Schedule service with P.K. Wadsworth Heating & Cooling today for top-rated HVAC, water heater, and plumbing services in Cleveland, OH.
Recent Jobs and Reviews in Cleveland, OH
Job Locations and Reviews
Returned to site to complete warranty leak search on HVAC system. Inspected refrigerant lines, connections, and mechanical components for potential leak sources. Documented equipment condition and connection points with photos for warranty records.
Responded to frozen refrigerant line condition on residential air conditioning system. Upon arrival, confirmed evaporator coil freeze-up on outdoor condenser unit. Instructed homeowner to power down system to allow complete defrost of refrigerant lines. Assessed P.K. Wadsworth furnace and air handler installation for proper airflow and filter status. Provided customer with filter replacement information and specifications for ongoing maintenance to prevent future freeze-up conditions caused by restricted airflow.
Responded to service call for air conditioning system experiencing electrical issues and water leakage. Upon inspection, found water accumulation on basement floor near air handler unit with visible staining indicating ongoing drainage problem. Identified malfunctioning red condensate pump at base of air handler as primary cause of water leak. Evaluated electrical connections to condensate pump and verified proper operation of drainage system. Inspected PVC condensate drain lines for blockages or improper pitch. Tested air handler operation and confirmed system functionality after addressing drainage issue. Provided customer education on maintenance value plan benefits and recommended enrollment for preventative maintenance including regular thermostat verification, ductwork inspection, blower wheel cleaning, electrical component testing, and heat exchanger diagnostics to prevent future issues.
# HVAC Cooling Maintenance Summary
Completed scheduled preventive maintenance on residential cooling system. Inspection revealed a heavily corroded capacitor with extensive rust and oxidation on the terminal plate and connections. Documented the deteriorated electrical component condition with multiple wire connections (blue, red, and yellow leads) showing signs of environmental exposure and age-related degradation. Verified all electrical connections and terminal blocks within the unit. System evaluated for proper operation and safety concerns related to the corroded components.
# Detailed Service Report
Performed comprehensive cooling system maintenance as part of ongoing preventive maintenance program. Upon inspection of the outdoor condensing unit, discovered significant corrosion on the run capacitor assembly. The capacitor's metal top plate exhibited extensive rust and oxidation, with three terminal posts showing advanced deterioration. The blade-style connectors attached to t
Installed new electrical junction box in attic space to address wiring concerns. Replaced dual toggle switch and cover plate, ensuring proper operation and secure mounting to wall surface.
Completed full system replacement estimate for aging HVAC system from the 1980's. Assessed existing equipment including furnace, evaporator coil, ductwork, and filtration system in confined attic space, documenting current conditions and presenting multiple replacement options to customer.
Conducted on-site assessment of aging boiler system exceeding 30 years of service in older residential property. Evaluated existing hydronic heating infrastructure including cast iron radiators with vertical fin design and associated supply/return piping connections. Documented current system condition through photographic records showing original radiator installations with floor-mounted valve assemblies and visible deterioration indicators. Provided homeowner with replacement boiler options and recommendations for system upgrade to improve heating efficiency and reliability given the advanced age of existing equipment.
Completed comprehensive cooling system maintenance inspection on HVAC unit. Performed electrical diagnostics using digital multimeter to verify proper voltage and amperage readings at control board and throughout the system. Inspected all electrical connections, capacitors, relays, and color-coded wiring harnesses within the unit compartment, confirming secure connections and proper component function for safe and efficient operation.
Responded to HVAC service call for air conditioning system with damaged wiring caused by rodent activity. Upon inspection, confirmed groundhog had chewed through electrical wiring to the outdoor condensing unit. Customer declined same-day repair of the damaged wiring.
Completed routine cooling season maintenance on residential HVAC system. Performed comprehensive inspection of all mechanical and electrical components, including furnace cabinet interior, control board, blower motor assembly, condensate drainage system, and ductwork connections. Verified proper operation of all system controls, checked electrical connections for security and signs of wear, and confirmed condensate trap and drainage lines are clear and functioning correctly. All components found operating within normal parameters with no immediate service needs identified.
Conducted on-site evaluation for mini split installation options. Assessed existing electrical infrastructure including main panel and Sub Panel 'A', documenting current circuit breaker configuration and available capacity to determine feasibility and requirements for mini split system integration. Photographed electrical panels to support equipment sizing recommendations and installation planning.
Completed scheduled cooling system maintenance on residential air conditioning unit. Performed comprehensive inspection of outdoor condensing unit, verified electrical parameters using digital multimeter, and measured system temperatures with calibrated digital thermometer recording 69.8°F. All components operating within normal specifications and unit functioning properly for continued cooling season operation.
Completed scheduled cooling system maintenance on outdoor HVAC unit. Inspected condenser fan assembly, motor housing, and protective grille which showed normal weathering and corrosion consistent with outdoor exposure. Examined electrical disconnect and Cutler-Hammer components, verified proper labeling and safety warnings visible. Unit operational with all components functioning within normal parameters at time of inspection.
Completed installation of Unico air handler system with coil for heat pump application. Wired control terminal block with proper 24V connections and verified all electrical terminations at the unit. Installed exterior condenser units on concrete pad with proper refrigerant line connections and confirmed system operational with service financing approval.
Completed electrical inspection of residential service entrance and main distribution panel. Documented exterior meter installation, service conduit routing, and associated utility connections mounted on brick exterior wall. Verified proper installation of flexible conduit connecting to ground-level equipment. Inspected interior main electrical panel containing split-bus configuration with dual main breaker assemblies and approximately 20-24 branch circuit breakers. Confirmed proper wire routing, conductor organization, and grounding connections throughout panel. All circuit breakers, wire terminations, and electrical connections photographed for record.
Completed preventive maintenance on two rooftop air conditioning units. Performed comprehensive inspection of both systems, including examination of condenser coils, fan motors, electrical connections, and refrigerant levels. Both units were found to be in operational condition with no immediate repairs required at time of service.
Completed routine cooling maintenance on residential heat pump system. Inspected outdoor condensing unit, electrical disconnect, and all accessible components. Verified proper operation of unit mounted on vibration-dampening pad with adequate clearance from building structure. Confirmed electrical connections at disconnect box secure, refrigerant lines intact, and unit operating within normal parameters for seasonal cooling performance.
Performed HVAC service call on air conditioning system. Inspected air handler unit and condensate drainage system. Found standing water in drain pan with visible staining and discoloration indicating drainage issues. Examined PVC condensate line configuration with trap assembly. Noted significant rust-colored mineral deposits and water staining on drain pan surface. Documented moisture accumulation and high humidity conditions within cabinet. Tested and evaluated drainage components including trap assembly and discharge piping. System components assessed for proper operation and water removal functionality.
# HVAC Cooling Maintenance Completed
Performed comprehensive cooling season maintenance on residential HVAC system consisting of Lennox furnace unit with integrated air handler. Conducted thorough inspection of all accessible mechanical and electrical components within both units. Verified proper operation of blower motor assembly, examined gas valve components, and inspected all electrical connections including capacitors and pressure switches for signs of wear or deterioration.
Evaluated condition of pleated air filters in air handler compartment and confirmed adequate airflow through system. Inspected flexible metal ductwork connections for proper sealing and structural integrity. All safety labels and manufacturer specifications were reviewed to ensure compliance with operational standards. System components showed normal wear consistent with age of installation, with no immediate service concerns identified. Unit remains in functional operating condition for continued cooling s
Completed cooling system tune-up on residential HVAC unit. Performed temperature diagnostics at supply duct measuring 58.4°F and electrical measurements at outdoor condensing unit showing 69.9V and 11.1A readings, confirming proper system operation and airflow performance.