Pepper Pike, OH, is a vibrant community with lots to love. Its location only about 30 minutes outside of Cleveland also makes it a prime destination for those looking for a home close to the city but not too close.
To keep your Pepper Pike, OH, home functioning at its best, you can trust P.K. Wadsworth Heating & Cooling. Our company offers residential and commercial plumbing and HVAC services. Whether your home’s AC won’t work or your business has a clogged drain, we can help.
Contact us now to schedule an appointment with the P.K. Wadsworth Heating & Cooling team.

Air Conditioning & Cooling Services
Is your AC system having issues? Don’t wait to get it checked out. P.K. Wadsworth Heating & Cooling offers cooling services, such as AC installation, replacement, repair, and maintenance.
Ductless Mini-Splits
A ductless mini-split unit is great for cooling small areas such as apartments or single rooms. If you want to add one to your home, contact us ASAP. We’ll handle the installation from start to finish.
Heat Pumps
Heat pumps can act as a heater and an AC unit for your home. Our technicians have the knowledge and skills to keep your heat pump in peak condition, whether it needs some maintenance or a lengthy repair.
Heating Repair & Replacement Services
You can’t afford to face the cold months without a reliable heater. Our skilled team provides all kinds of heating services, including installation, replacement, repair, and maintenance services. No matter what’s wrong with your heater, you can trust us to troubleshoot and get the heat flowing in your home again.
Furnaces
The furnace is one of the most common home heaters in Pepper Pike, OH. That’s why the P.K. Wadsworth Heating & Cooling team is highly skilled at working with gas, electric, and oil furnaces. We can fix your old furnace or install a new one if necessary.
Boilers
Boilers are another common way to heat houses, but unlike other heaters, they use water and steam to generate heat. Boilers can have unique issues that make them hard to service, so you want to hire a company that knows how to handle them. P.K. Wadsworth Heating & Cooling’s boiler experts can quickly handle your boiler repair or replacement work.
Indoor Air Quality Services in Pepper Pike
Is the air in your home clean? If you’ve never taken advantage of our air quality services, then maybe not. We can help you get clean, high-quality air in your home with products like:
Comprehensive Water Heater & Plumbing Services
P.K. Wadsworth Heating & Cooling is here for all your plumbing service needs. We can handle minor issues like clogged drains and major issues like water heater repairs. We can work on both traditional and tankless water heaters, so don’t hesitate to reach out if you notice problems with your unit.
Trust P.K. Wadsworth Heating & Cooling In Pepper Pike
P.K. Wadsworth Heating & Cooling is a trustworthy business in Pepper Pike, OH, for good reason. Your neighbors rely on us for their HVAC needs because:
- We put customer satisfaction first: We have over 32,000 five-star reviews to prove it.
- We’re experienced: Our family-owned and -operated business has been helping customers for over 85 years.
- We’re trained: Our certified technicians have what it takes to handle various HVAC- or plumbing-related problems.
Contact us now to find out what P.K. Wadsworth Heating & Cooling can do for you.
P.K. Wadsworth Heating, Cooling, Plumbing and Electric has completed 20 jobs in Pepper Pike, OH between June 2026 and July 2026. The most recent job was on July 6, 2026.Recent Jobs and Reviews in Pepper Pike, OH
Pepper Pike, OH at a glance
Job Locations and Reviews
# HVAC Cooling Maintenance Summary
Completed scheduled preventive maintenance on residential cooling system including furnace, air handler, and associated refrigerant lines. Performed comprehensive inspection of all major components, verified proper operation of Aprilaire humidifier unit, checked refrigerant line connections and insulation integrity, and confirmed electrical connections throughout the system. All equipment found to be operating within normal parameters with no issues identified.
# Detailed Work Performed
Conducted routine cooling season maintenance on residential HVAC system located in basement utility area. Performed visual inspection of gray metal furnace/air handler unit, confirming proper mounting and structural integrity. Inspected Aprilaire whole-house humidifier installation and verified secure connections to main air handling unit.
Examined copper refrigerant line routing and mounting brackets for proper support and alignment. Checked insulation wrapping on
Responded to recurring water leak issue on HVAC system that was previously reinstalled 1.5 months prior. Upon arrival, observed heavy condensation and frost accumulation on supply ductwork indicating ongoing moisture problem that has caused property damage. Inspected condensate drain system and confirmed water sensor safety float switch is malfunctioning and not shutting down unit when water is present. Documented extensive condensation on metal ductwork and inadequate insulation at duct seams, as well as condensate management system requiring repair to prevent further water damage.
Responded to no cooling complaint on upstairs AC unit. Upon inspection, diagnosed system issue and verified refrigerant temperatures reading 23°F at evaporator coil. Inspected outdoor condensing unit, checked electrical components including capacitor and compressor connections, and restored proper system operation.
Returned to site to complete replacement of condenser fan motor and run capacitor on 2.5 ton Concord condensing unit. Successfully installed new components, verified proper electrical connections, tested system operation, and confirmed unit is running within manufacturer specifications.
Completed comprehensive cooling system tune-up and performance evaluation. Utilized digital diagnostic instruments to measure system temperatures, pressures, and airflow parameters throughout the equipment and ductwork. All readings confirmed system operating within manufacturer specifications for optimal cooling efficiency.
Performed routine maintenance on 20-year-old HVAC system including filter replacement and comprehensive system inspection. Measured operating amperage at 13.11A and voltage at 0.300V using digital multimeter to verify electrical performance. System found operating within normal parameters with no issues identified during tune-up service.
Completed scheduled preventative maintenance on residential cooling system. Performed comprehensive inspection of indoor furnace unit and associated components in mechanical room, verifying proper operation of blower assembly, checking electrical connections, and inspecting condensate drainage system with PVC piping. Proceeded to outdoor unit where electrical disconnect box was inspected and tested for proper functionality. Confirmed disconnect switch operates correctly and all wiring connections are secure within the exterior-mounted enclosure. System tested and operating within normal parameters upon completion of maintenance service.
Conducted on-site evaluation of existing outdoor air conditioning condenser unit for replacement estimate. Unit displayed weathered exterior surfaces with visible discoloration and signs of prolonged outdoor exposure. Assessed surrounding conditions including overgrown vegetation encroaching on equipment, which may restrict proper airflow and reduce system efficiency. Documented current equipment specifications, installation location against exterior wall with mixed siding types, and accessibility for replacement work. Photographed existing unit positioning, clearance requirements, and electrical connections to provide comprehensive replacement options for customer consideration.
Conducted on-site evaluation for tankless water heater installation. Assessed existing plumbing configuration, gas line accessibility, and venting requirements to provide comprehensive replacement estimate.
Conducted comprehensive estimate evaluation for furnace replacement in residential property. Assessed existing brown/tan metal furnace unit with side-mounted humidifier system, documented current thermostat configuration (White-Rodgers digital unit), and evaluated overall HVAC system layout including existing ductwork and mechanical room conditions. Provided homeowner with multiple furnace replacement options based on equipment age, configuration, and space requirements.
Completed installation of new air conditioning system in basement utility area. Installed air handler unit with associated electrical connections and conduit work, configured PVC venting system in U-shaped configuration for proper intake and exhaust, and connected sheet metal ductwork to integrate with existing furnace system. All equipment mounted on concrete floor per manufacturer specifications, electrical components properly wired and secured, and system tested for proper operation upon completion.
Completed scheduled preventive maintenance on Carrier cooling system. Performed comprehensive inspection of indoor air handler unit, including electrical components and capacitor functionality. Verified refrigerant line connections, insulation integrity, and all electrical terminations at dual-run capacitor (45/7.5μF, 440VAC). All system components operating within manufacturer specifications with no deficiencies noted.
Completed scheduled preventive maintenance on residential cooling system. Performed comprehensive electrical diagnostics using clamp meter to verify amperage draw and voltage readings at outdoor unit, confirming proper compressor operation and electrical performance within manufacturer specifications. Inspected control board wiring connections, terminal blocks, and low-voltage thermostat circuits for secure connections and proper function. All system components operating normally with no deficiencies noted.
Completed comprehensive cooling system tune-up on residential HVAC unit. Inspected and serviced all major components including condenser unit, evaporator coil, and electrical connections. Noted significant corrosion on capacitor terminals and mounting hardware, indicating prolonged moisture exposure; capacitor remains functional but will require monitoring for future replacement. Verified system airflow, checked refrigerant levels, cleaned accessible components, and confirmed proper operation of all safety controls and thermostat functionality.
Conducted on-site assessment of existing HVAC system in basement utility area to provide replacement options for air conditioning equipment. Evaluated current furnace and air handler configuration, noting accessible installation location with adequate clearance for equipment service and replacement. Documented existing ductwork assembly, PVC drainage lines, and ventilation routing to determine compatibility requirements for new AC system integration. Photographed current equipment layout showing furnace unit, wrapped ductwork, horizontal and vertical PVC piping with proper mounting supports, and surrounding mechanical components. Prepared two AC replacement options tailored to the straightforward access conditions and existing infrastructure, accounting for the organized installation space and proper support structures already in place.
Returned to site to replace defective air scrubber UV bulb as scheduled. Removed existing contaminated filter assembly from air purification unit, installed new UV lamp component, and reassembled system to restore proper air sanitization functionality.
Responded to no cooling complaint and conducted system evaluation. Assessed outdoor condensing unit and indoor furnace/coil assembly to provide replacement options for failed air conditioning system. Documented existing equipment configuration including furnace installation and exterior condensing unit location for estimate preparation.
Completed scheduled preventive maintenance on two outdoor HVAC cooling systems. Performed comprehensive inspection of electrical components including capacitors, contactors, and wiring connections on both units. Tested system operation and verified all connections were secure with no signs of electrical issues requiring immediate attention.
Completed scheduled preventive maintenance on residential cooling system. Performed comprehensive inspection of outdoor condensing unit and indoor control board assembly, verifying proper operation of all electrical components, connections, and control circuits. Documented system condition with photographs showing control board functionality and exterior equipment installation for maintenance records.
Responded to no-cooling call and performed diagnostic inspection of residential air conditioning system. Verified furnace and indoor air handler operation in basement, confirmed proper electrical connections and ductwork integrity. Inspected outdoor condenser unit, checked fan assembly and motor operation, and verified unit returned to normal cooling function. System tested and confirmed operational upon completion.