P.K. Wadsworth Heating & Cooling has kept Shaker Heights homeowners comfortable since 1936. We’re experts in climate control who have consistently earned the loyalty and trust of customers by exceeding expectations with best-in-class technicians, reliable service, and custom solutions.
Whether it’s through our preventative maintenance plans, installation of heating and cooling systems, or efficient and effective HVAC repair throughout Shaker Heights, our flexibility, professionalism, industry knowledge, and friendly staff have made all the difference for more than 80 years.
Contact our local HVAC company for repair, replacement, and maintenance services in the Shaker Heights, Ohio area.
Heating Services In Shaker Heights

P.K. Wadsworth is the leading HVAC company in Cleveland, providing heating services in Shaker Heights. From heating system repair to replacement, we’ll perform necessary tasks to keep your system in prime condition while providing you the peace of mind that your home heating is as reliable, safe and efficient as possible. P.K. Wadsworth offers the following heating services:
- Furnace installation
- Furnace replacement
- Furnace maintenance
- Furnace repair
- Boiler installation
- Boiler replacement
- Boiler maintenance
- Boiler repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
Contact us to schedule top-rated heating services, such as furnace repair, heating replacement, and heating installation in Shaker Heights!
Air Conditioning Services In Shaker Heights
With P.K. Wadsworth, an HVAC technician will assess your Shaker Heights home, budget, and comfort preferences. In order to keep you and your family comfortable—even when the temperatures are reaching record highs—we offer the following air conditioner services in Shaker Heights:
- Air conditioner installation
- Air conditioner replacement
- Air conditioner maintenance
- Air conditioner repair
- Ductless system installation
- Ductless system replacement
- Ductless system maintenance
- Ductless system repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
- Contact our local HVAC company to schedule air conditioner services, such as AC repair, replacement, and maintenance in Shaker Heights!
Indoor Air Quality In Shaker Heights, Ohio

Many people are surprised to learn that indoor air can be many times more polluted than outdoor air. That’s because most buildings today are sealed tight to keep heated and cooled air from leaking out. Although this conserves energy, it can create indoor air that’s infested with invisible pollutants that adversely affect health and well-being. Keep the air quality in your Shaker Heights home as clean as possible with our top-rated indoor air quality services.
When you need indoor air quality services in Shaker Heights, there’s only one name you need to know—P.K. Wadsworth.
Choose P.K. Wadsworth As Your Shaker Heights HVAC Company
P.K. Wadsworth has one of the most experienced HVAC companies in Shaker Heights, Ohio. All of our heating and cooling professionals are trained and certified to work on most heating and air conditioning systems, regardless of the brand. From heating replacement to AC repair in Shaker Heights, you can trust our team to get the job done right.
Contact our local HVAC company to schedule heating or air conditioning services throughout Shaker Heights—including AC or furnace repair, HVAC replacement, and HVAC maintenance.
P.K. Wadsworth Heating, Cooling, Plumbing and Electric has completed 20 jobs in Shaker Heights, OH in May 2026. The most recent job was on May 12, 2026.Recent Jobs and Reviews in Shaker Heights, OH
Shaker Heights, OH at a glance
Job Locations and Reviews
Responded to service call for reported boiler pipe leak. Upon inspection, identified significant corrosion and rust buildup at threaded pipe joint connection on boiler supply piping. Documented existing conditions showing deteriorated gray pipe elbow fitting with orange-brown rust concentration at joint interface and aging plumbing infrastructure with mixed piping materials including PVC, copper, and metal components.
Completed routine cooling system maintenance on residential HVAC unit. Performed refrigerant pressure diagnostics using digital manifold gauges, confirming R410A refrigerant charge at 232.0 PSIG on high side with system operating within normal parameters at 69°F ambient temperature. Inspected furnace cabinet, venting components, and associated electrical connections for proper operation and safety compliance.
Completed comprehensive cooling system maintenance on residential HVAC unit located in basement utility area. Performed standard preventive maintenance procedures including inspection of furnace and cooling components, verification of proper airflow through heat exchanger coils, and temperature differential measurements using calibrated digital thermometer. Measured supply and return air temperatures across evaporator coil, recording readings of 26.5°F and 5.33°F differential, confirming adequate system performance and refrigerant charge levels within manufacturer specifications. Noted minor dust and debris accumulation on aluminum fins of heat exchanger unit, which is normal for seasonal operation. All ductwork connections, including flexible ducting, inspected and found secure with no visible air leaks. System operational and functioning properly upon completion of maintenance service.
Performed comprehensive cooling maintenance on attic-mounted air handler system. Inspected evaporator coil assembly, noting dust accumulation on finned surfaces but confirmed structural integrity remains intact. Verified air handler unit installation, ductwork connections, and flexible duct insulation throughout attic space. All system components operational and properly secured within confined attic environment.
Relocated existing AC circuit and associated electrical components to accommodate customer needs. Accessed exterior meter installation and basement crawl space to reroute wiring through floor joists and structural supports. Installed new conduit routing, secured electrical cables with appropriate hangers and mounting brackets, and verified proper circuit protection and meter functionality. All work completed to code specifications with system tested and operational upon completion.
Completed scheduled HVAC boiler maintenance inspection and system diagnostics. Verified proper operation of all electrical components, tested control board functionality with digital display reading 30°F, and performed amperage measurements using clamp meter to confirm system is operating within manufacturer specifications.
Conducted estimate for air conditioning system replacement after unit sustained damage from falling ice during winter months. Evaluated outdoor condenser unit positioned on concrete pad against building exterior and inspected interior HVAC components including ductwork connections and air handling equipment. Provided customer with multiple replacement options ranging from condenser-only replacement to complete system upgrade based on extent of ice damage to existing equipment.
Responded to customer report of hole in pipe connected to furnace system. Upon inspection, discovered damaged drywall/ceiling material with exposed PVC venting pipes from furnace exhaust system. Documented existing conditions showing white PVC vent pipes with compromised ceiling access point and structural opening requiring attention. Assessed plumbing and venting infrastructure in crawl space area, noting PVC drainage/ventilation components with support strapping in place. Customer made aware of findings and photographic documentation completed for repair planning purposes.
Replaced chandelier-style light fixture in dining room and installed new ceiling fan with integrated light kit in upstairs bedroom. Both fixtures were tested for proper operation and illumination upon completion.
Completed annual preventative maintenance service on residential split-system air conditioning unit as part of scheduled maintenance plan. Performed comprehensive inspection of outdoor condensing unit, which was found in good operating condition with no visible signs of damage, corrosion, or deterioration. Unit is properly positioned on concrete pad with adequate clearance and surrounded by well-maintained landscaping. Verified all manufacturer labels and safety decals are present and legible. Inspected fan assembly, cabinet louvers, and external components for proper condition. Confirmed refrigerant line set and associated piping connections are secure with no visible signs of leakage or damage. System demonstrates normal operational characteristics consistent with routine maintenance visit.
Responded to service call for reported furnace leak. Upon arrival, found significant water accumulation and staining on basement floor surrounding HVAC unit. Inspected furnace and identified failed condensate drainage system as source of water intrusion. Placed collection bucket to contain active dripping while assessing extent of damage. Photographed water damage patterns on concrete floor and traced condensate line routing. Recommended immediate condensate pump replacement or drain line clearing to prevent further water damage to basement floor and potential secondary heat exchanger issues from improper drainage.
Leveled outdoor condenser unit using gravel base material to ensure proper equipment operation and drainage. Unit was checked with precision level and adjusted to manufacturer specifications for optimal performance and compressor longevity.
Conducted site evaluation for heat pump and air handler replacement options. Assessed existing mechanical access cabinet and ductwork configuration in utility space, documenting current system layout and installation conditions. Photographed exterior unit location area including foundation access points and drainage conditions to determine optimal equipment placement for replacement system.
Completed routine cooling system maintenance and hot water tank service. Performed electrical diagnostics using digital multimeter to verify system performance and inspected evaporator coil, which showed moderate dust and debris accumulation on aluminum fins but maintained proper structural integrity with no bent fins or refrigerant line damage. All components tested within normal operating parameters.
Completed preventive maintenance on two residential cooling systems. Performed comprehensive inspection of both outdoor condenser units, including examination of refrigerant line connections, electrical wiring, and capacitor components. Verified proper operation of all electrical connections, terminal blocks, and control wiring. Inspected refrigerant line insulation and service valves for signs of wear or deterioration. Both systems found to be in normal operating condition with all components functioning within manufacturer specifications.
Completed preventive maintenance on three outdoor condensing units, including one Daikin condenser and two additional cooling systems. Performed standard cooling season inspection procedures on all exterior units, verified refrigerant line connections, and inspected electrical conduit routing. Indoor ductless mini-split head unit was visually inspected and confirmed operational.
Responded to service call for reported boiler leak. Upon inspection, identified active water seepage at corroded brass compression fitting on copper supply piping. Fitting and surrounding pipe connections exhibited severe oxidation with heavy verdigris buildup and mineral deposits, indicating prolonged moisture exposure. Documented extensive corrosion at threaded union connections requiring replacement to resolve leak and prevent system failure.
Completed comprehensive preventive maintenance on residential cooling system. Performed inspection of outdoor condenser unit, verifying proper operation of compressor, fan motor, and electrical connections. Checked indoor air handler components including blower assembly and control board mounted in attic space. All equipment operating within normal parameters with no deficiencies noted. System tested and confirmed cooling efficiently.
Completed comprehensive heating and cooling maintenance on residential HVAC system following customer's extended absence from the country. Performed full inspection and maintenance procedures on furnace unit, ductwork, copper piping manifold system with multiple zone valves, and associated components to ensure proper operation of both heating and cooling systems.
Conducted site assessment for ceiling fan installation in bedroom with no existing ceiling fan fixture. Evaluated electrical infrastructure including current switch location and wiring configuration to determine installation requirements and provide accurate estimate for fixture addition.