P.K. Wadsworth Heating & Cooling has kept Shaker Heights homeowners comfortable since 1936. We’re experts in climate control who have consistently earned the loyalty and trust of customers by exceeding expectations with best-in-class technicians, reliable service, and custom solutions.
Whether it’s through our preventative maintenance plans, installation of heating and cooling systems, or efficient and effective HVAC repair throughout Shaker Heights, our flexibility, professionalism, industry knowledge, and friendly staff have made all the difference for more than 80 years.
Contact our local HVAC company for repair, replacement, and maintenance services in the Shaker Heights, Ohio area.
Heating Services In Shaker Heights

P.K. Wadsworth is the leading HVAC company in Cleveland, providing heating services in Shaker Heights. From heating system repair to replacement, we’ll perform necessary tasks to keep your system in prime condition while providing you the peace of mind that your home heating is as reliable, safe and efficient as possible. P.K. Wadsworth offers the following heating services:
- Furnace installation
- Furnace replacement
- Furnace maintenance
- Furnace repair
- Boiler installation
- Boiler replacement
- Boiler maintenance
- Boiler repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
Contact us to schedule top-rated heating services, such as furnace repair, heating replacement, and heating installation in Shaker Heights!
Air Conditioning Services In Shaker Heights
With P.K. Wadsworth, an HVAC technician will assess your Shaker Heights home, budget, and comfort preferences. In order to keep you and your family comfortable—even when the temperatures are reaching record highs—we offer the following air conditioner services in Shaker Heights:
- Air conditioner installation
- Air conditioner replacement
- Air conditioner maintenance
- Air conditioner repair
- Ductless system installation
- Ductless system replacement
- Ductless system maintenance
- Ductless system repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
- Contact our local HVAC company to schedule air conditioner services, such as AC repair, replacement, and maintenance in Shaker Heights!
Indoor Air Quality In Shaker Heights, Ohio

Many people are surprised to learn that indoor air can be many times more polluted than outdoor air. That’s because most buildings today are sealed tight to keep heated and cooled air from leaking out. Although this conserves energy, it can create indoor air that’s infested with invisible pollutants that adversely affect health and well-being. Keep the air quality in your Shaker Heights home as clean as possible with our top-rated indoor air quality services.
When you need indoor air quality services in Shaker Heights, there’s only one name you need to know—P.K. Wadsworth.
Choose P.K. Wadsworth As Your Shaker Heights HVAC Company
P.K. Wadsworth has one of the most experienced HVAC companies in Shaker Heights, Ohio. All of our heating and cooling professionals are trained and certified to work on most heating and air conditioning systems, regardless of the brand. From heating replacement to AC repair in Shaker Heights, you can trust our team to get the job done right.
Contact our local HVAC company to schedule heating or air conditioning services throughout Shaker Heights—including AC or furnace repair, HVAC replacement, and HVAC maintenance.
P.K. Wadsworth Heating, Cooling, Plumbing and Electric has completed 20 jobs in Shaker Heights, OH in September 2026. The most recent job was on September 9, 2026.Recent Jobs and Reviews in Shaker Heights, OH
Shaker Heights, OH at a glance
Job Locations and Reviews
Completed comprehensive cooling maintenance on aging HVAC system as part of ongoing preventive maintenance program. Performed full system inspection of furnace and air conditioning components in basement mechanical room, verified operational parameters, and documented temperature differential readings of 25.4 degrees, indicating proper cooling performance. All equipment photographed and confirmed to be functioning within manufacturer specifications for continued reliable operation.
Performed comprehensive annual maintenance and tune-up on 9-year-old New Yorker residential boiler system. Conducted thorough inspection of burner assembly, heat exchanger, and all operational components. Based on service history indicating previous backflow valve clogging that caused mid-winter shutdown, performed detailed examination and cleaning of the backflow preventer, confirming proper operation and flow rates. All safety controls, pressure relief valves, and electrical connections tested and verified within manufacturer specifications. System cycled successfully with no operational issues detected.
Conducted on-site assessment for residential backup generator installation. Evaluated electrical service capacity, identified optimal generator placement location on exterior deck area, and documented existing conditions including available space and proximity to electrical panel. Provided comprehensive estimate for generator system installation including necessary electrical connections and transfer switch requirements.
Completed comprehensive preventive maintenance on two furnace heating systems. Performed thorough inspections of both units, including electrical diagnostics using clamp meter to verify proper amperage draw on blower motors and system components. Measured and recorded temperature differentials across heat exchangers to ensure optimal heat transfer efficiency. Inspected all electrical connections, wiring, and capacitors for signs of wear or degradation. Verified proper operation of all safety controls and limit switches. Both systems tested and operating within manufacturer specifications upon completion of maintenance procedures.
Responded to service call regarding two non-functional circuits following knob and tube rewiring project. Customer reported that these circuits served infrequently used areas and had been previously advised that some circuits might require additional work post-rewire. Inspected outdoor electrical fixtures and associated wiring in crawlspace and exterior locations, documenting existing conditions including HVAC ductwork proximity, outdoor brick grill structure with electrical components, and accessible wiring pathways for troubleshooting and future remediation.
Responded to service call for air conditioning system not cooling properly due to reported coil leak. Upon inspection, diagnosed failed capacitor on outdoor condensing unit. Removed defective capacitor and installed replacement component. System tested and verified operational with proper cooling function restored.
Completed first-year preventive maintenance on cooling system, including comprehensive electrical testing of compressor motor windings using megohmmeter to verify insulation resistance within acceptable parameters. Inspected and tested contactor operation, verified all electrical connections and wire terminations at control panel, and documented system condition with readings indicating proper electrical integrity throughout the unit.
Responded to no cooling complaint on residential air conditioning system. Upon arrival, performed diagnostic testing using refrigerant analyzer which revealed system operating at 579 PSIG with 46.2°F superheat and 6.7°F subcooling readings. These measurements indicate the system requires further evaluation of refrigerant charge and potential leak assessment to restore proper cooling operation.
Responded to service call for rodent damage to air conditioning system wiring in attic space. Upon inspection, confirmed that rodents had chewed through insulation covering on electrical wiring to AC unit, leaving conductors exposed. Documented damage with photographs showing affected wiring runs and overall attic conditions including HVAC ductwork routing and structural layout. Advised customer of findings and necessary repairs to restore safe electrical connections and proper insulation coverage to prevent further deterioration or potential electrical hazards.
Conducted comprehensive HVAC system evaluation and provided full replacement options for residential forced air system. Assessed existing air handler unit located in attic space, including ductwork configuration, condensate drainage system, and overall equipment condition. Presented complete replacement estimates to homeowner covering equipment upgrades, installation specifications, and system optimization recommendations.
Responded to service call for loud buzzing noise on recently installed Goodman air conditioning system. Upon arrival, performed diagnostic inspection of indoor furnace unit and blower motor assembly. Identified issue with blower motor experiencing mechanical noise during startup cycles. Inspected motor mounting, bearings, and fan wheel assembly for loose components or obstructions. Verified proper electrical connections and capacitor function. Documented equipment condition with photographs showing furnace installation and blower motor assembly details. Unit is under manufacturer warranty coverage. Provided customer with findings and recommended contacting warranty service for authorized motor replacement or repair to resolve buzzing noise issue.
Responded to water leak complaint on 11-year-old Amana AC unit with water present on laundry room floor. Upon inspection, discovered evaporator coil heavily contaminated with dust and debris accumulation, particularly on left section of cooling fins, causing restricted airflow and drain pan overflow. Cleaned evaporator coil fins, cleared primary condensate drain line, verified proper drainage, and tested system operation to confirm resolution of leak issue.
Responded to no cooling complaint on aging HVAC system. Performed comprehensive system inspection including exterior disconnect, refrigerant lines, and attic air handler components. Verified system operation, checked electrical connections, and assessed overall condition of equipment to diagnose cooling issue.
Completed preventive maintenance on 6-year-old Carrier cooling system. Inspected indoor Amana furnace unit and outdoor condenser, checked refrigerant levels, cleaned condenser coils, tested electrical connections, verified proper airflow and system operation. All components functioning within manufacturer specifications; system ready for cooling season.
Performed maintenance and repair on residential furnace system. Removed and thoroughly cleaned blower wheel assembly to restore proper airflow and system efficiency. Replaced failed capacitor to ensure reliable motor operation. Tested system operation and confirmed proper function of all components upon completion.
Completed a 200 AMP electrical panel upgrade with surge protection installation. Removed the existing outdated panel and installed a new 200 AMP main service panel to meet current electrical code requirements and provide increased capacity for the property. Integrated whole-house surge protection device to safeguard electrical systems and connected appliances from voltage spikes and power surges.
Responded to cooling complaint with thermostat set at 72°F but space temperature reading 76°F. Performed system diagnostics and temperature measurements at multiple points including supply air reading 52.5°F and return air reading 75°F. Based on previous service history indicating potential refrigerant loss and current temperature differential analysis, system performance suggests possible refrigerant leak requiring further leak search procedure to identify and resolve underlying issue.
Completed scheduled cooling system maintenance visit on residential HVAC unit. Performed comprehensive inspection of air handler assembly, including blower motor, squirrel cage fan wheel, and electrical connections. Verified proper motor operation and measured electrical current draw using clamp meter, confirming amperage readings within manufacturer specifications at 0.04A. Inspected all wiring connections, including power leads and grounding wire, ensuring secure terminations and no signs of wear or overheating. Examined blower motor housing, mounting bracket, and surrounding ductwork for proper installation and structural integrity. All components found operating normally with no deficiencies noted. System returned to service in proper working condition.
Completed scheduled plumbing maintenance visit for water heater fulfillment and inspection. Performed visual assessment of Bradford White automatic storage water heater unit, verifying proper installation, connections, and operational status. Documented equipment condition including copper piping connections, pressure relief valve, gas input specifications, and safety labeling compliance.
Performed preventive maintenance tune-up on two outdoor condensing units serving ductless mini-split system. Completed standard inspection procedures including checking refrigerant levels, cleaning condenser coils, testing electrical connections, and verifying proper operation of both indoor wall-mounted air handler and outdoor compressor units. Presented customer with information regarding available maintenance value plan options for future service needs.