P.K. Wadsworth Heating & Cooling has kept Shaker Heights homeowners comfortable since 1936. We’re experts in climate control who have consistently earned the loyalty and trust of customers by exceeding expectations with best-in-class technicians, reliable service, and custom solutions.
Whether it’s through our preventative maintenance plans, installation of heating and cooling systems, or efficient and effective HVAC repair throughout Shaker Heights, our flexibility, professionalism, industry knowledge, and friendly staff have made all the difference for more than 80 years.
Contact our local HVAC company for repair, replacement, and maintenance services in the Shaker Heights, Ohio area.
Heating Services In Shaker Heights

P.K. Wadsworth is the leading HVAC company in Cleveland, providing heating services in Shaker Heights. From heating system repair to replacement, we’ll perform necessary tasks to keep your system in prime condition while providing you the peace of mind that your home heating is as reliable, safe and efficient as possible. P.K. Wadsworth offers the following heating services:
- Furnace installation
- Furnace replacement
- Furnace maintenance
- Furnace repair
- Boiler installation
- Boiler replacement
- Boiler maintenance
- Boiler repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
Contact us to schedule top-rated heating services, such as furnace repair, heating replacement, and heating installation in Shaker Heights!
Air Conditioning Services In Shaker Heights
With P.K. Wadsworth, an HVAC technician will assess your Shaker Heights home, budget, and comfort preferences. In order to keep you and your family comfortable—even when the temperatures are reaching record highs—we offer the following air conditioner services in Shaker Heights:
- Air conditioner installation
- Air conditioner replacement
- Air conditioner maintenance
- Air conditioner repair
- Ductless system installation
- Ductless system replacement
- Ductless system maintenance
- Ductless system repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
- Contact our local HVAC company to schedule air conditioner services, such as AC repair, replacement, and maintenance in Shaker Heights!
Indoor Air Quality In Shaker Heights, Ohio

Many people are surprised to learn that indoor air can be many times more polluted than outdoor air. That’s because most buildings today are sealed tight to keep heated and cooled air from leaking out. Although this conserves energy, it can create indoor air that’s infested with invisible pollutants that adversely affect health and well-being. Keep the air quality in your Shaker Heights home as clean as possible with our top-rated indoor air quality services.
When you need indoor air quality services in Shaker Heights, there’s only one name you need to know—P.K. Wadsworth.
Choose P.K. Wadsworth As Your Shaker Heights HVAC Company
P.K. Wadsworth has one of the most experienced HVAC companies in Shaker Heights, Ohio. All of our heating and cooling professionals are trained and certified to work on most heating and air conditioning systems, regardless of the brand. From heating replacement to AC repair in Shaker Heights, you can trust our team to get the job done right.
Contact our local HVAC company to schedule heating or air conditioning services throughout Shaker Heights—including AC or furnace repair, HVAC replacement, and HVAC maintenance.
P.K. Wadsworth Heating, Cooling, Plumbing and Electric has completed 20 jobs in Shaker Heights, OH in August 2026. The most recent job was on August 8, 2026.Recent Jobs and Reviews in Shaker Heights, OH
Shaker Heights, OH at a glance
Job Locations and Reviews
Responded to service call for outdoor condensing unit with slow motor rotation and insufficient compression. Upon inspection, diagnosed failed run capacitor causing reduced motor speed and compromised compressor operation. Removed defective capacitor, tested electrical readings with clamp meter to verify proper voltage and amperage, and installed new replacement capacitor. Verified proper motor operation and compressor function upon startup, restoring unit to normal operating condition.
Completed routine cooling maintenance on residential HVAC system. Inspected and tested electrical components including capacitor, which showed significant corrosion and rust on terminals but maintained proper electrical function. Measured supply air temperature at 58°F through main ductwork. Verified system operation and confirmed adequate cooling performance throughout inspection.
Completed scheduled preventative maintenance on two residential HVAC cooling systems. Performed comprehensive inspection of air handler unit, verified refrigerant lines and connections, checked system operation and temperature differentials using digital testing equipment. Inspected evaporator coil for frost buildup and proper airflow, examined all mechanical components, labels, and safety systems for compliance. Both systems operating within normal parameters with no immediate service needs identified.
Conducted on-site evaluation for HVAC system replacement in home currently equipped with boiler heat and no existing cooling system. Assessed attic space for potential Unico high-velocity air conditioning installation options and reviewed existing electrical panel capacity for system integration. Customer requested inclusion of whole-house generator in estimate for comprehensive home comfort and backup power solution.
Completed warranty inspection on HVAC installation identifying two issues requiring correction. Installed missing tamper caps on outdoor unit furthest from street and properly sealed plenum on unit near basement stairs where side panel had separated creating a one-inch gap. All deficiencies documented with photos and corrected to manufacturer specifications.
# HVAC Cooling Maintenance Summary
Completed routine preventive maintenance on residential cooling system as part of ongoing service plan. Performed comprehensive inspection of air handling unit, verifying proper airflow and examining air filter condition. Filter displayed "LIVE FREE. BREATHE FREELY." branding and showed normal service wear. Inspected flexible metallic ductwork for integrity and proper connection. Accessed outdoor condensing unit control panel mounted on exterior brick wall. Examined electrical components including dual green circuit boards, control wiring, transformer assembly, and all electrical connections. Verified proper wire terminations on red, white, green, yellow, and black conductors. All system components operating within normal parameters with no deficiencies noted.
Returned to property to complete installation of replacement control board on Goodman furnace unit. Successfully replaced defective control board, restored power to unit, and verified proper operation of all heating system functions. System tested and confirmed operating within normal parameters.
Completed preventative maintenance on two cooling systems. Inspected electrical components including capacitor, contactor, and control wiring for proper operation and secure connections. Examined blower wheel assembly and verified fan operation for optimal airflow performance.
Completed comprehensive preventive maintenance on residential cooling system. Inspected indoor air handler unit in basement mechanical room, verifying proper operation of all components, drainage systems, and electrical connections. Performed outdoor condenser unit inspection, checking refrigerant lines, condensate drainage, electrical connections, and overall equipment condition. All systems operating within normal parameters with no deficiencies noted.
Performed routine maintenance flush on Bradford White tanked water heater to remove sediment buildup and ensure optimal performance. Drained tank completely using garden hose, inspected all plumbing connections and shut-off valves, verified proper venting system operation, and refilled unit to restore hot water service.
Completed routine HVAC cooling system maintenance on residential split system. Inspected and replaced air filter, verified proper operation of outdoor condenser unit, and confirmed all components functioning within normal parameters.
Completed comprehensive cooling system maintenance on residential HVAC unit. Performed thorough inspection of outdoor condenser unit, verifying proper operation of capacitor, contactor, and electrical connections, with all components found to be in good working condition. Inspected indoor furnace and air handling equipment, confirmed proper venting configuration and system integration.
Completed scheduled cooling system preventative maintenance visit on residential air conditioning unit. Performed comprehensive system inspection including electrical measurements using clamp meter, recording amperage draws and voltage readings to verify proper compressor and fan motor operation. Inspected and tested all electrical connections at terminal block, ensuring secure wire terminations and proper contact integrity throughout the system.
Conducted on-site assessment for twinned air conditioning system replacement. Evaluated existing indoor air handler unit located in garage utility space and dual outdoor condenser configuration consisting of one traditional box-style unit and one cylindrical unit positioned along exterior fence line. Documented current equipment condition, ductwork connections, condensate drainage system with PVC piping, and refrigerant line routing between indoor and outdoor components. Provided comprehensive replacement options for the twinned system setup to address customer's cooling needs.
Responded to service call for reported evaporator coil leak on residential HVAC system. Upon arrival, performed diagnostic evaluation of the air conditioning and furnace unit. Conducted electrical testing of the outdoor condensing unit components using multimeter to verify proper system operation and rule out any electrical issues that could affect system performance. Inspected capacitors, contactor, and associated wiring connections within the outdoor unit's control panel. Proceeded to indoor unit to investigate reported leak condition at evaporator coil assembly. Examined evaporator coil, drain pan, and condensate drainage system for signs of water accumulation or leakage. Applied dye or leak detection methods to identify source of moisture issue. Documented equipment conditions through photographic evidence for service records and customer reference.
Completed cooling tune-up on residential HVAC system. Connected manifold gauges to outdoor condensing unit and verified refrigerant pressures and system operation. Measured supply air temperature at 52.3°F in ductwork, confirming proper cooling performance and adequate temperature split across evaporator coil.
Conducted comprehensive HVAC system evaluation for full system replacement estimate. Assessed existing ductwork installation in basement mechanical space, including main supply plenum and distribution components. Inspected duct sealing at connection points with aluminum foil tape and evaluated overall duct integrity. Reviewed current equipment configuration and spatial constraints for potential new system installation. Provided multiple equipment options for air conditioning replacement as well as complete HVAC system upgrade alternatives to meet customer needs.
# HVAC Cooling Maintenance - Two Systems
Completed comprehensive preventive maintenance service on two cooling systems as part of recurring maintenance agreement. Performed thorough inspection of electrical components including fuse assemblies, verifying proper condition and secure mounting of TR25R fuses in disconnect panel. Conducted amperage draw measurements using clamp meter on system components, recording operational readings to verify equipment performance within manufacturer specifications. All electrical connections, wiring, and control components inspected and found in satisfactory operating condition. Both cooling systems tested and confirmed operational.
Responded to service call for gas line capping in preparation for customer's conversion from gas to electric stove. Successfully capped the existing gas supply line to the stove location per code requirements to ensure safe disconnection of the gas appliance. Work completed in basement utility area with proper shutoff and testing procedures followed.
Responded to emergency no-cooling call on 3-year-old system. Located severed low-voltage wire in attic space between HVAC equipment and thermostat. Repaired damaged wire connection, restored power to system, and verified proper operation of Aprilaire humidifier control and cooling function.