Pepper Pike, OH, is a vibrant community with lots to love. Its location only about 30 minutes outside of Cleveland also makes it a prime destination for those looking for a home close to the city but not too close.
To keep your Pepper Pike, OH, home functioning at its best, you can trust P.K. Wadsworth Heating & Cooling. Our company offers residential and commercial plumbing and HVAC services. Whether your home’s AC won’t work or your business has a clogged drain, we can help.
Contact us now to schedule an appointment with the P.K. Wadsworth Heating & Cooling team.

Air Conditioning & Cooling Services
Is your AC system having issues? Don’t wait to get it checked out. P.K. Wadsworth Heating & Cooling offers cooling services, such as AC installation, replacement, repair, and maintenance.
Ductless Mini-Splits
A ductless mini-split unit is great for cooling small areas such as apartments or single rooms. If you want to add one to your home, contact us ASAP. We’ll handle the installation from start to finish.
Heat Pumps
Heat pumps can act as a heater and an AC unit for your home. Our technicians have the knowledge and skills to keep your heat pump in peak condition, whether it needs some maintenance or a lengthy repair.
Heating Repair & Replacement Services
You can’t afford to face the cold months without a reliable heater. Our skilled team provides all kinds of heating services, including installation, replacement, repair, and maintenance services. No matter what’s wrong with your heater, you can trust us to troubleshoot and get the heat flowing in your home again.
Furnaces
The furnace is one of the most common home heaters in Pepper Pike, OH. That’s why the P.K. Wadsworth Heating & Cooling team is highly skilled at working with gas, electric, and oil furnaces. We can fix your old furnace or install a new one if necessary.
Boilers
Boilers are another common way to heat houses, but unlike other heaters, they use water and steam to generate heat. Boilers can have unique issues that make them hard to service, so you want to hire a company that knows how to handle them. P.K. Wadsworth Heating & Cooling’s boiler experts can quickly handle your boiler repair or replacement work.
Indoor Air Quality Services in Pepper Pike
Is the air in your home clean? If you’ve never taken advantage of our air quality services, then maybe not. We can help you get clean, high-quality air in your home with products like:
Comprehensive Water Heater & Plumbing Services
P.K. Wadsworth Heating & Cooling is here for all your plumbing service needs. We can handle minor issues like clogged drains and major issues like water heater repairs. We can work on both traditional and tankless water heaters, so don’t hesitate to reach out if you notice problems with your unit.
Trust P.K. Wadsworth Heating & Cooling In Pepper Pike
P.K. Wadsworth Heating & Cooling is a trustworthy business in Pepper Pike, OH, for good reason. Your neighbors rely on us for their HVAC needs because:
- We put customer satisfaction first: We have over 32,000 five-star reviews to prove it.
- We’re experienced: Our family-owned and -operated business has been helping customers for over 85 years.
- We’re trained: Our certified technicians have what it takes to handle various HVAC- or plumbing-related problems.
Contact us now to find out what P.K. Wadsworth Heating & Cooling can do for you.
P.K. Wadsworth Heating, Cooling, Plumbing and Electric has completed 20 jobs in Pepper Pike, OH between October 2026 and November 2026. The most recent job was on November 20, 2026. P.K. Wadsworth Heating, Cooling, Plumbing and Electric has completed 208 jobs in Pepper Pike, OH in the last 12 months.Recent Jobs and Reviews in Pepper Pike, OH
Pepper Pike, OH at a glance
Job Locations and Reviews


Installed a new 50-gallon power-vent gas water heater with an ICON System gas control, complete with a thermal expansion tank mounted on the supply line. Connected the copper water supply lines, gas line with shutoff valve, and PVC power-vent piping, and verified the unit is operating with the status indicator confirming normal function.


Assessed the existing Lochinvar PVN05050 natural gas water heater (5.0 gal capacity) for replacement, which serves a portion of the building's domestic hot water. Inspected the unit and surrounding installation area, noting rust or moisture staining on the concrete floor beneath the tank and verifying clear access for removal and installation of a replacement unit.


Replaced the failed condensate pump serving the Goodman forced-air furnace and reconnected the discharge tubing and electrical connections. Verified proper pump operation and condensate drainage, and confirmed the furnace cabinet and surrounding area were free of active water leaks.


Performed scheduled heating maintenance on two furnaces, including inspection of the blower assemblies, wiring harnesses, and terminal connections, and cleaning of accumulated dust and debris from the cabinets. Verified proper operation through electrical testing of the blower motor circuit with a clamp meter and temperature measurements with a digital thermometer. Confirmed condensate drain trap condition and left both systems operating normally.


Performed scheduled heating maintenance on the furnace, including replacement of the 20x25x4 pleated return air filter (MERV 10) and inspection of the air handler cabinet. Inspected the PVC condensate drain assembly and clear trap, noting minor discoloration and residue in the trap, and confirmed the access caps and drain components were in place for proper condensate drainage.


Performed a heating system tune-up, inspecting the furnace's internal components including the flame sensor/igniter, pressure switch assemblies, and wiring connections, with no visible damage, corrosion, or anomalies found. Verified system operation by measuring supply air temperature at the duct using a digital thermometer probe to confirm proper heating performance.


Performed seasonal heating maintenance on three gas furnace systems, inspecting burner assemblies, gas valves, inducer and blower motors, control boards, and wiring connections for proper operation. Observed rust staining beneath the burner compartment on one unit indicating prior moisture exposure, and verified the condensate drain line and pump were intact; control boards and wiring showed no signs of burning, corrosion, or damage. All systems were left operational.


Performed scheduled heating maintenance on the furnace, including inspection of the control board, low-voltage and line-voltage wiring, and cabinet interior. Verified blower motor operation by measuring amperage draw with a true RMS clamp meter (approx. 14.9 A). Noted discolored, grimy control components and torn, frayed cabinet insulation, which may warrant further evaluation.


Performed seasonal heating maintenance on two systems, including inspection of supply ductwork and verification of supply air temperature with a digital thermometer, which read approximately 138°F at the duct, indicating proper heat output. Checked duct seams, transition collars, and sealant for leaks or deterioration and found no visible corrosion or damage; both systems were operating normally at completion.


Diagnosed and replaced a failed run capacitor, which tested well below its rated microfarad value under load, and replaced the furnace pressure switch, which showed heavy residue and contamination. Verified proper operation after the repairs, including a normal startup sequence and blower function.


Performed scheduled heating maintenance on the furnace, including inspection of the igniter/flame sensor, inducer motor assembly, pressure switch, transformer, and low-voltage wiring connections, with no signs of rust, breakage, or loose terminations. Verified electrical operation of the system by measuring amperage draw with a clamp meter, and confirmed the unit was in proper working order at completion.


Installed a 26kW standby generator with standard 5-year engine, 3-year parts, and 2-year labor warranty coverage. Routed conduit and flexible tubing along the exterior wall beneath the elevated deck structure, with electrical and plumbing connections run to the unit location.


Performed a heating system tune-up and cleaning on a 9-year-old unit, including replacement of the return air filter with a new pleated Filtrete filter installed in the correct airflow direction. Inspected the heat exchanger with a borescope camera to verify the condition of the internal passages and combustion chamber, and confirmed the system is operating properly.


Performed scheduled heating maintenance on a 27-year-old Lennox system, inspecting the air handler and blower compartment and measuring supply duct temperature, which read 133.7°F. Observed rust on the blower motor end cap and an unterminated green wire with exposed bare copper near the blower housing, along with a purple wire resting across the blower wheel; recommend securing and properly terminating the wiring and monitoring motor condition due to equipment age.


Performed scheduled heating maintenance on two furnace systems under a recurring service plan, inspecting the control boards, wiring connections, and cabinet interiors. Verified proper electrical operation by measuring amperage draw with a clamp meter at the furnace wiring, and checked air temperature with a pocket thermometer to confirm system performance. Both units were found operating within normal parameters.


Performed scheduled heating maintenance on the furnace, including electrical diagnostics with a digital clamp meter to verify component operation and amperage draw. Measured duct temperature with a digital thermometer to confirm proper heat output; the readings were within normal operating range and no damage or abnormalities were observed on the ductwork.


Returned to complete the dedicated electrical circuit for the Daikin R32 inverter outdoor condensing unit as part of the warranty installation. Ran flexible metal conduit and conductors from the interior junction box through the basement ceiling to the exterior disconnect and unit connection, secured with clamps along the wall. Verified proper termination and unit power-up.


Performed a seasonal heating tune-up on the furnace, including electrical diagnostics with a True RMS clamp meter to measure amp draw on the blower and component circuits. Inspected the gas valve assembly, gas piping connections, and internal wiring for proper operation and secure connections, and verified the system was operating within normal parameters.


Responded to a callback for a dead wall receptacle. Removed the cover plate and pulled the outlet from the wall box, then used a multimeter to test for voltage and continuity and trace the loss of power. Inspected the electrical panel and branch circuit to verify breaker and supply conditions, then restored power to the receptacle.


Replaced the warranty pressure switches on the gas furnace, reconnecting the wiring to the new switches and securing the harness. Verified proper burner flame operation after installation, and monitored temperatures with a digital thermometer to confirm the system was running correctly.