Top-Rated Heating Repair & AC Replacement in Twinsburg, OH
Call Today (440) 248-2110 Schedule Service
Friday Deals are Live! Click Here to Claim Your Offers!
Friday Deals are Live! Click Here to Claim Your Offers!

AC, Heating & Plumbing Services in Twinsburg, OH

P.K. Wadsworth Heating & Cooling has striven to give our clients the best heating, AC, and water heater services available since 1936. Since then, we’ve earned over 32,000 five-star reviews from our residential and commercial clients. When your home systems give you trouble, we’ll be there to help so you can spend your time keeping your business running or enjoying all our beautiful city has to offer, including Liberty Park and Blue Hen Falls.

Contact P.K. Wadsworth Heating & Cooling for dependable HVAC and water heater solutions in Twinsburg, OH.

Thermostatic mixing valve regulating temperature for home's hot water to a safe level

Reliable AC & Cooling Services

When the temperature rises, having AC you can count on is critical. A home without air conditioning is left open to an overload of contaminants, putting indoor air quality at risk. We offer various cooling services to keep your air conditioner running, including installation, replacement, repair, and maintenance. Our knowledgeable technicians can handle multiple systems, including:

  • Ductless mini-splits: These modern options are a fantastic solution for homes that lack the ductwork a traditional AC system requires. They can also be combined with other AC types to improve energy efficiency.
  • Heat pumps: You can combine heating and cooling into one with a heat pump, which offers lower-cost solutions for maintaining your home’s temperature.

Thorough Heating Repair & Replacement

Heat is crucial to the health and comfort of your home as Twinsburg temperatures drop. Our expert heating technicians are trained in various heating services, including replacement, installation, maintenance, and repair. We have decades of knowledge and are capable of handling multiple systems like:

  • Furnaces: Whether you’re having issues with your pilot light or the unit isn’t hot enough, we can fix your gas, electric, or oil furnace.
  • Boilers: These units offer dual capabilities of heating your home and providing hot water.

Indoor Air Quality Services in Twinsburg

The condition of your indoor air influences every area of your life. If it’s unhealthy, so are you. This is why we supply the best indoor air quality services available.

  • Air purifiers: Systems like HEPA filters rid the air in your home of debris, pet dander, and other contaminants, lessening the load on your respiratory system.
  • Air scrubbers: These units remove mold, pollen, odors, and germs, allowing your loved ones to breathe more easily.
  • Humidifiers: Air craves moisture, and when it’s too dry, it’ll take it from any source, including you and your furniture. Using a humidifier helps balance humidity levels and protect your home and body.
  • Dehumidifiers: When the air is too humid, mildew and mold grow in walls, risking damage to wooden structures. Dehumidifiers help protect your home by ridding it of excess moisture.

Top-Rated Water Heater & Plumbing Services

A working plumbing system is a cornerstone of a modern home, and hot water is key in multiple areas of life, including hygiene and cooking. We offer expert plumbing services to keep your pipes and water-based appliances running smoothly, such as:

  • Water heater services: Whether you’re experiencing no hot water or some other issue, our expert plumbing technicians can fix it.
  • Tankless water heater services: When sized to your needs, these units offer several benefits, including endless hot water. If you want to add a tankless water heater to your life, our knowledgeable technicians will be happy to walk you through the options.

Schedule With P.K. Wadsworth Heating & Cooling In Twinsburg Today

With over eight decades in business, P.K. Wadsworth Heating & Cooling understands the Twinsburg area. We’re family-operated and passionate about delivering reliable services on time. We keep our estimates free and our pricing upfront and instant, so there are no nasty surprises. To help take the headache out of maintaining your home systems, we offer same-day services and maintenance plans.

For professional home services in the Twinsburg area, schedule an appointment with P.K. Wadsworth Heating & Cooling today!

 

Recent Jobs and Reviews in Twinsburg, OH

Job Locations and Reviews

# HVAC Cooling System Maintenance

Performed routine cooling system maintenance on outdoor condensing unit as part of scheduled preventive maintenance program. Accessed electrical disconnect box and inspected internal components including capacitor, contactors, and associated wiring connections. Verified proper electrical connections across multiple circuits with red, yellow, purple, blue, green, and black conductor wiring. Utilized True RMS clamp meter to measure voltage, amperage, and electrical parameters to ensure system operating within manufacturer specifications. All electrical components tested and found functioning properly with no deficiencies noted. Unit operational and ready for cooling season.
# HVAC Cooling System Maintenance

Performed routine cooling system maintenance on outdoor condensing unit as part of scheduled preventive maintenance program. Accessed electrical disconnect box and inspected internal components including capacitor, contactors, and associated wiring connections. Verified proper electrical connections across multiple circuits with red, yellow, purple, blue, green, and black conductor wiring. Utilized True RMS clamp meter to measure voltage, amperage, and electrical parameters to ensure system operating within manufacturer specifications. All electrical components tested and found functioning properly with no deficiencies noted. Unit operational and ready for cooling season.
Miguel F.
Miguel F. Checked in
# HVAC Cooling System Maintenance Performed routine cooling system maintenance on outdoor condensing unit as part of scheduled preventive maintenance program. Accessed electrical disconnect box and inspected internal components including capacitor, contactors, and associated wiring connections. Verified proper electrical connections across multiple circuits with red, yellow, purple, blue, green, and black conductor wiring. Utilized True RMS clamp meter to measure voltage, amperage, and electrical parameters to ensure system operating within manufacturer specifications. All electrical components tested and found functioning properly with no deficiencies noted. Unit operational and ready for cooling season.
Twinsburg, OH 44087
Completed comprehensive cooling system maintenance inspection in residential attic and basement mechanical spaces. Inspected all accessible ductwork, verified proper connections at main trunk junctions, checked condensate drain lines for proper pitch and secure mounting, and examined air handler components for operational integrity. Documented humidifier control unit status, verified electrical connections at junction boxes, and confirmed all mechanical equipment was functioning within normal parameters with no immediate service needs identified.
Completed comprehensive cooling system maintenance inspection in residential attic and basement mechanical spaces. Inspected all accessible ductwork, verified proper connections at main trunk junctions, checked condensate drain lines for proper pitch and secure mounting, and examined air handler components for operational integrity. Documented humidifier control unit status, verified electrical connections at junction boxes, and confirmed all mechanical equipment was functioning within normal parameters with no immediate service needs identified.
Anthony L.
Anthony L. Checked in
Completed comprehensive cooling system maintenance inspection in residential attic and basement mechanical spaces. Inspected all accessible ductwork, verified proper connections at main trunk junctions, checked condensate drain lines for proper pitch and secure mounting, and examined air handler components for operational integrity. Documented humidifier control unit status, verified electrical connections at junction boxes, and confirmed all mechanical equipment was functioning within normal parameters with no immediate service needs identified.
Twinsburg, OH 44087
Performed routine cooling system maintenance as part of recurring preventive service agreement. Conducted comprehensive system diagnostics using digital multimeter to verify electrical components and measure operating voltages, ensuring all readings were within manufacturer specifications. Completed standard inspection protocol for air conditioning equipment, documenting system performance through photographic records for service history files.
Performed routine cooling system maintenance as part of recurring preventive service agreement. Conducted comprehensive system diagnostics using digital multimeter to verify electrical components and measure operating voltages, ensuring all readings were within manufacturer specifications. Completed standard inspection protocol for air conditioning equipment, documenting system performance through photographic records for service history files.
Jerrell H.
Jerrell H. Checked in
Performed routine cooling system maintenance as part of recurring preventive service agreement. Conducted comprehensive system diagnostics using digital multimeter to verify electrical components and measure operating voltages, ensuring all readings were within manufacturer specifications. Completed standard inspection protocol for air conditioning equipment, documenting system performance through photographic records for service history files.
Twinsburg, OH 44087
Completed comprehensive cooling season maintenance on residential air conditioning system. Performed visual inspection of outdoor condenser unit, verified proper operation of fan assembly, checked refrigerant line connections for security and signs of leakage, and confirmed unit was level on gravel pad with adequate clearance for airflow. System operating within normal parameters upon completion of maintenance procedures.
Completed comprehensive cooling season maintenance on residential air conditioning system. Performed visual inspection of outdoor condenser unit, verified proper operation of fan assembly, checked refrigerant line connections for security and signs of leakage, and confirmed unit was level on gravel pad with adequate clearance for airflow. System operating within normal parameters upon completion of maintenance procedures.
Anthony L.
Anthony L. Checked in
Completed comprehensive cooling season maintenance on residential air conditioning system. Performed visual inspection of outdoor condenser unit, verified proper operation of fan assembly, checked refrigerant line connections for security and signs of leakage, and confirmed unit was level on gravel pad with adequate clearance for airflow. System operating within normal parameters upon completion of maintenance procedures.
Twinsburg, OH 44087
Returned to complete repair work on outdoor condensing unit. Replaced failed condenser fan motor, run capacitor, and contactor. Installed hard start kit to assist compressor during startup cycles. Performed thorough coil cleaning to remove heavy accumulation of dirt, debris, and organic material that had significantly restricted airflow. Cleared vegetation encroaching on unit to restore proper clearance for adequate ventilation and future serviceability. Unit tested and confirmed operational upon completion.
Returned to complete repair work on outdoor condensing unit. Replaced failed condenser fan motor, run capacitor, and contactor. Installed hard start kit to assist compressor during startup cycles. Performed thorough coil cleaning to remove heavy accumulation of dirt, debris, and organic material that had significantly restricted airflow. Cleared vegetation encroaching on unit to restore proper clearance for adequate ventilation and future serviceability. Unit tested and confirmed operational upon completion.
Miguel F.
Miguel F. Checked in
Returned to complete repair work on outdoor condensing unit. Replaced failed condenser fan motor, run capacitor, and contactor. Installed hard start kit to assist compressor during startup cycles. Performed thorough coil cleaning to remove heavy accumulation of dirt, debris, and organic material that had significantly restricted airflow. Cleared vegetation encroaching on unit to restore proper clearance for adequate ventilation and future serviceability. Unit tested and confirmed operational upon completion.
Twinsburg, OH 44087
Twinsburg, OH - Responded to customer inquiry regarding installation of 240V dedicated circuit in garage for electric vehicle charging station. Conducted on-site assessment and documented existing electrical panel configuration, which showed available capacity in main distribution panel with multiple open breaker positions. Panel inspection revealed adequate space and proper clearances for additional circuit installation. Photographed current electrical infrastructure including panel layout, wire routing, and garage workspace conditions to develop accurate installation quote and scope of work for the requested EV charger circuit.
Dylan C.
Dylan C. Checked in
Responded to customer inquiry regarding installation of 240V dedicated circuit in garage for electric vehicle charging station. Conducted on-site assessment and documented existing electrical panel configuration, which showed available capacity in main distribution panel with multiple open breaker positions. Panel inspection revealed adequate space and proper clearances for additional circuit installation. Photographed current electrical infrastructure including panel layout, wire routing, and garage workspace conditions to develop accurate installation quote and scope of work for the requested EV charger circuit.
Twinsburg, OH 44087
Completed full HVAC system replacement estimate presenting three tiered equipment options for outdoor condensing unit and gas furnace installation. Good tier option included 13.4 SEER air conditioner with 80% AFUE furnace, Better tier featured 14 SEER unit with 96% AFUE high-efficiency furnace, and Best tier consisted of 16 SEER air conditioner paired with 96% AFUE furnace. Assessed existing equipment location with easy accessibility, documented current outdoor unit positioned on concrete pad with refrigerant line routing along exterior brick wall, and photographed installation site conditions including ground clearances and utility connections to facilitate accurate replacement planning.
Completed full HVAC system replacement estimate presenting three tiered equipment options for outdoor condensing unit and gas furnace installation. Good tier option included 13.4 SEER air conditioner with 80% AFUE furnace, Better tier featured 14 SEER unit with 96% AFUE high-efficiency furnace, and Best tier consisted of 16 SEER air conditioner paired with 96% AFUE furnace. Assessed existing equipment location with easy accessibility, documented current outdoor unit positioned on concrete pad with refrigerant line routing along exterior brick wall, and photographed installation site conditions including ground clearances and utility connections to facilitate accurate replacement planning.
Malcolm A.
Malcolm A. Checked in
Completed full HVAC system replacement estimate presenting three tiered equipment options for outdoor condensing unit and gas furnace installation. Good tier option included 13.4 SEER air conditioner with 80% AFUE furnace, Better tier featured 14 SEER unit with 96% AFUE high-efficiency furnace, and Best tier consisted of 16 SEER air conditioner paired with 96% AFUE furnace. Assessed existing equipment location with easy accessibility, documented current outdoor unit positioned on concrete pad with refrigerant line routing along exterior brick wall, and photographed installation site conditions including ground clearances and utility connections to facilitate accurate replacement planning.
Twinsburg, OH 44087
Responded to service call for furnace making extremely loud noise. Upon arrival, inspection revealed the photos captured were of a water heater rather than the furnace system. Water heater exhibited significant rust and corrosion on top surface around pipe connections, with deteriorated condition of unit noted. No furnace service was documented or performed during this visit.
Responded to service call for furnace making extremely loud noise. Upon arrival, inspection revealed the photos captured were of a water heater rather than the furnace system. Water heater exhibited significant rust and corrosion on top surface around pipe connections, with deteriorated condition of unit noted. No furnace service was documented or performed during this visit.
Salvador B.
Salvador B. Checked in
Responded to service call for furnace making extremely loud noise. Upon arrival, inspection revealed the photos captured were of a water heater rather than the furnace system. Water heater exhibited significant rust and corrosion on top surface around pipe connections, with deteriorated condition of unit noted. No furnace service was documented or performed during this visit.
Twinsburg, OH 44087
Repaired refrigerant leak on suction line at condenser unit. Performed leak detection using electronic refrigerant leak detector, brazed damaged section of suction line, evacuated system to 500 microns, and recharged unit to manufacturer specifications.
Repaired refrigerant leak on suction line at condenser unit. Performed leak detection using electronic refrigerant leak detector, brazed damaged section of suction line, evacuated system to 500 microns, and recharged unit to manufacturer specifications.
Sam K.
Sam K. Checked in
Repaired refrigerant leak on suction line at condenser unit. Performed leak detection using electronic refrigerant leak detector, brazed damaged section of suction line, evacuated system to 500 microns, and recharged unit to manufacturer specifications.
Twinsburg, OH 44087
Conducted on-site evaluation for electric vehicle charging station installation. Assessed existing electrical infrastructure including main service panel capacity and meter configuration to determine feasibility and requirements for EV charger circuit addition. Documented current electrical system conditions and provided comprehensive quote for customer consideration.
Conducted on-site evaluation for electric vehicle charging station installation. Assessed existing electrical infrastructure including main service panel capacity and meter configuration to determine feasibility and requirements for EV charger circuit addition. Documented current electrical system conditions and provided comprehensive quote for customer consideration.
Dylan C.
Dylan C. Checked in
Conducted on-site evaluation for electric vehicle charging station installation. Assessed existing electrical infrastructure including main service panel capacity and meter configuration to determine feasibility and requirements for EV charger circuit addition. Documented current electrical system conditions and provided comprehensive quote for customer consideration.
Twinsburg, OH 44087
Conducted on-site assessment of existing HVAC system and water heating equipment located in utility closet. Evaluated current configuration including water heater, expansion tank, PVC and copper piping connections, and ductwork arrangement. Documented equipment layout and measured available space, noting 9-foot clearance for replacement unit installation. Provided customer with equipment replacement options and specifications for system upgrade.
Conducted on-site assessment of existing HVAC system and water heating equipment located in utility closet. Evaluated current configuration including water heater, expansion tank, PVC and copper piping connections, and ductwork arrangement. Documented equipment layout and measured available space, noting 9-foot clearance for replacement unit installation. Provided customer with equipment replacement options and specifications for system upgrade.
Malcolm A.
Malcolm A. Checked in
Conducted on-site assessment of existing HVAC system and water heating equipment located in utility closet. Evaluated current configuration including water heater, expansion tank, PVC and copper piping connections, and ductwork arrangement. Documented equipment layout and measured available space, noting 9-foot clearance for replacement unit installation. Provided customer with equipment replacement options and specifications for system upgrade.
Twinsburg, OH 44087
Completed scheduled preventive cooling maintenance on residential HVAC system. Performed comprehensive inspection of outdoor Daikin heat pump unit including examination of fan assembly, condenser coils, and exterior components. Verified proper operation of indoor air handler and furnace system, checked refrigerant lines, electrical connections, and condensate drainage. All equipment operating within normal parameters with no deficiencies noted.
Completed scheduled preventive cooling maintenance on residential HVAC system. Performed comprehensive inspection of outdoor Daikin heat pump unit including examination of fan assembly, condenser coils, and exterior components. Verified proper operation of indoor air handler and furnace system, checked refrigerant lines, electrical connections, and condensate drainage. All equipment operating within normal parameters with no deficiencies noted.
Ethan M.
Ethan M. Checked in
Completed scheduled preventive cooling maintenance on residential HVAC system. Performed comprehensive inspection of outdoor Daikin heat pump unit including examination of fan assembly, condenser coils, and exterior components. Verified proper operation of indoor air handler and furnace system, checked refrigerant lines, electrical connections, and condensate drainage. All equipment operating within normal parameters with no deficiencies noted.
Twinsburg, OH 44087
Conducted comprehensive assessment of existing HVAC system showing significant age-related deterioration, including heavily corroded copper refrigerant lines and aging air handler equipment. Presented customer with multiple replacement options including full system replacement and air conditioning unit replacement only, documented current system condition through detailed photography of equipment cabinet, ductwork, refrigerant piping, and electrical components to support estimate recommendations.
Conducted comprehensive assessment of existing HVAC system showing significant age-related deterioration, including heavily corroded copper refrigerant lines and aging air handler equipment. Presented customer with multiple replacement options including full system replacement and air conditioning unit replacement only, documented current system condition through detailed photography of equipment cabinet, ductwork, refrigerant piping, and electrical components to support estimate recommendations.
Eric B.
Eric B. Checked in
Conducted comprehensive assessment of existing HVAC system showing significant age-related deterioration, including heavily corroded copper refrigerant lines and aging air handler equipment. Presented customer with multiple replacement options including full system replacement and air conditioning unit replacement only, documented current system condition through detailed photography of equipment cabinet, ductwork, refrigerant piping, and electrical components to support estimate recommendations.
Twinsburg, OH 44087
Completed scheduled cooling system maintenance on HVAC air handler unit. Performed comprehensive inspection of system components including damper assembly, actuator mechanism, and electrical connections. Verified proper operation of motorized damper and control wiring. Inspected and evaluated air filter condition, confirming adequate airflow through pleated media filter. Examined ductwork connections and verified system accessibility for ongoing maintenance requirements.
Completed scheduled cooling system maintenance on HVAC air handler unit. Performed comprehensive inspection of system components including damper assembly, actuator mechanism, and electrical connections. Verified proper operation of motorized damper and control wiring. Inspected and evaluated air filter condition, confirming adequate airflow through pleated media filter. Examined ductwork connections and verified system accessibility for ongoing maintenance requirements.
Salvador B.
Salvador B. Checked in
Completed scheduled cooling system maintenance on HVAC air handler unit. Performed comprehensive inspection of system components including damper assembly, actuator mechanism, and electrical connections. Verified proper operation of motorized damper and control wiring. Inspected and evaluated air filter condition, confirming adequate airflow through pleated media filter. Examined ductwork connections and verified system accessibility for ongoing maintenance requirements.
Twinsburg, OH 44087
# HVAC Heating System Maintenance Completed

Performed comprehensive first-year heating system maintenance on residential HVAC unit. Conducted thorough inspection of control board assembly, verifying proper operation of dual green circuit boards with digital display readouts and confirming all electrical connections, wire terminals, and connector blocks were secure throughout the control panel enclosure. Inspected complete ductwork network including galvanized metal supply and return ducts, elbow joints, and connection points for proper airflow and structural integrity. Examined air filtration system and verified filter condition. All system components found operating within normal parameters with no immediate service needs identified.
# HVAC Heating System Maintenance Completed

Performed comprehensive first-year heating system maintenance on residential HVAC unit. Conducted thorough inspection of control board assembly, verifying proper operation of dual green circuit boards with digital display readouts and confirming all electrical connections, wire terminals, and connector blocks were secure throughout the control panel enclosure. Inspected complete ductwork network including galvanized metal supply and return ducts, elbow joints, and connection points for proper airflow and structural integrity. Examined air filtration system and verified filter condition. All system components found operating within normal parameters with no immediate service needs identified.
Anthony L.
Anthony L. Checked in
# HVAC Heating System Maintenance Completed Performed comprehensive first-year heating system maintenance on residential HVAC unit. Conducted thorough inspection of control board assembly, verifying proper operation of dual green circuit boards with digital display readouts and confirming all electrical connections, wire terminals, and connector blocks were secure throughout the control panel enclosure. Inspected complete ductwork network including galvanized metal supply and return ducts, elbow joints, and connection points for proper airflow and structural integrity. Examined air filtration system and verified filter condition. All system components found operating within normal parameters with no immediate service needs identified.
Twinsburg, OH 44087
Responded to customer concern regarding chemical odor in basement following recent coil cleaning service. Performed thorough inspection of air conditioning system and evaporator coil area. Upon examination, found significant corrosion and rust buildup in condensate drain pan, indicating long-term moisture accumulation and potential drainage issues. Inspected evaporator coil and confirmed chemical cleaning residue present on coil surfaces and surrounding components. Verified refrigerant lines and ductwork connections for proper installation. Advised customer that chemical smell is temporary and should dissipate as system continues to run and residual cleaning solution evaporates from coil surfaces. Recommended monitoring odor over next 24-48 hours of operation. Noted condensate pan corrosion requires attention to prevent future water damage and ensure proper drainage function.
Responded to customer concern regarding chemical odor in basement following recent coil cleaning service. Performed thorough inspection of air conditioning system and evaporator coil area. Upon examination, found significant corrosion and rust buildup in condensate drain pan, indicating long-term moisture accumulation and potential drainage issues. Inspected evaporator coil and confirmed chemical cleaning residue present on coil surfaces and surrounding components. Verified refrigerant lines and ductwork connections for proper installation. Advised customer that chemical smell is temporary and should dissipate as system continues to run and residual cleaning solution evaporates from coil surfaces. Recommended monitoring odor over next 24-48 hours of operation. Noted condensate pan corrosion requires attention to prevent future water damage and ensure proper drainage function.
Mike M.
Mike M. Checked in
Responded to customer concern regarding chemical odor in basement following recent coil cleaning service. Performed thorough inspection of air conditioning system and evaporator coil area. Upon examination, found significant corrosion and rust buildup in condensate drain pan, indicating long-term moisture accumulation and potential drainage issues. Inspected evaporator coil and confirmed chemical cleaning residue present on coil surfaces and surrounding components. Verified refrigerant lines and ductwork connections for proper installation. Advised customer that chemical smell is temporary and should dissipate as system continues to run and residual cleaning solution evaporates from coil surfaces. Recommended monitoring odor over next 24-48 hours of operation. Noted condensate pan corrosion requires attention to prevent future water damage and ensure proper drainage function.
Twinsburg, OH 44087
Performed diagnostic evaluation on non-operational air conditioning system at customer's request after receiving replacement quote from another contractor. Conducted thorough inspection of outdoor condensing unit, electrical connections, refrigerant lines, and associated components to identify root cause of system failure and determine whether repair or replacement was most appropriate solution.
Performed diagnostic evaluation on non-operational air conditioning system at customer's request after receiving replacement quote from another contractor. Conducted thorough inspection of outdoor condensing unit, electrical connections, refrigerant lines, and associated components to identify root cause of system failure and determine whether repair or replacement was most appropriate solution.
Peter A.
Peter A. Checked in
Performed diagnostic evaluation on non-operational air conditioning system at customer's request after receiving replacement quote from another contractor. Conducted thorough inspection of outdoor condensing unit, electrical connections, refrigerant lines, and associated components to identify root cause of system failure and determine whether repair or replacement was most appropriate solution.
Twinsburg, OH 44087
Performed routine cooling system maintenance on residential HVAC unit. Inspected outdoor condenser unit, refrigerant lines, and electrical connections, confirming all components operational. Evaluated air filter condition in return air housing, noting accumulated dust and debris from normal operation, with filter media showing adequate airflow capacity for continued use.
Performed routine cooling system maintenance on residential HVAC unit. Inspected outdoor condenser unit, refrigerant lines, and electrical connections, confirming all components operational. Evaluated air filter condition in return air housing, noting accumulated dust and debris from normal operation, with filter media showing adequate airflow capacity for continued use.
Michael M.
Michael M. Checked in
Performed routine cooling system maintenance on residential HVAC unit. Inspected outdoor condenser unit, refrigerant lines, and electrical connections, confirming all components operational. Evaluated air filter condition in return air housing, noting accumulated dust and debris from normal operation, with filter media showing adequate airflow capacity for continued use.
Twinsburg, OH 44087
Completed routine maintenance flush on tankless water heater system. Performed descaling procedure, inspected internal components including heat exchanger assembly and mounting hardware, verified proper operation of electrical connections and water flow pathways, and documented equipment condition with photographic records.
Completed routine maintenance flush on tankless water heater system. Performed descaling procedure, inspected internal components including heat exchanger assembly and mounting hardware, verified proper operation of electrical connections and water flow pathways, and documented equipment condition with photographic records.
Benjamin L.
Benjamin L. Checked in
Completed routine maintenance flush on tankless water heater system. Performed descaling procedure, inspected internal components including heat exchanger assembly and mounting hardware, verified proper operation of electrical connections and water flow pathways, and documented equipment condition with photographic records.
Twinsburg, OH 44087
Responded to service call for AC system leaking heavily in basement during operation. Upon arrival, inspected HVAC equipment and drainage system in utility closet. Identified compromised condensate drain pan as source of water leak. Assessed wall damage in adjacent hallway caused by water infiltration from failed drainage system. Documented equipment condition and leak damage with photographs. Discussed repair versus replacement options with customer based on extent of drain pan failure and resulting water damage to surrounding structure.
Responded to service call for AC system leaking heavily in basement during operation. Upon arrival, inspected HVAC equipment and drainage system in utility closet. Identified compromised condensate drain pan as source of water leak. Assessed wall damage in adjacent hallway caused by water infiltration from failed drainage system. Documented equipment condition and leak damage with photographs. Discussed repair versus replacement options with customer based on extent of drain pan failure and resulting water damage to surrounding structure.
Peter A.
Peter A. Checked in
Responded to service call for AC system leaking heavily in basement during operation. Upon arrival, inspected HVAC equipment and drainage system in utility closet. Identified compromised condensate drain pan as source of water leak. Assessed wall damage in adjacent hallway caused by water infiltration from failed drainage system. Documented equipment condition and leak damage with photographs. Discussed repair versus replacement options with customer based on extent of drain pan failure and resulting water damage to surrounding structure.
Twinsburg, OH 44087

What To Expect

Discover the P.K. Wadsworth Heating & Cooling Difference

Over 85 Years of Service in Ohio

P.K. Wadsworth Heating & Cooling has kept homeowners throughout the Greater Cleveland area comfortable since 1936.

Upfront Pricing

No surprise or hidden fees when you get your invoice. We ensure you always know exactly what you’re paying for before any work starts.

Timely Service

When you call us, you can expect timely responses to your HVAC or water heater requests & on-time arrivals to your home.

Over 2k Google Reviews

With over 2k five-star Google reviews, you know you can trust us with any heating, cooling, or water heater services.

Your Local Experts

As a locally operated business, we’ve been proud to serve the Cleveland, OH, community for nearly 100 years.

Unmatched Warranties & Guarantees

You can trust that we will always provide warranties and guarantees for our services in writing.

Over 85 Years of Service in Ohio

P.K. Wadsworth Heating & Cooling has kept homeowners throughout the Greater Cleveland area comfortable since 1936.

Upfront Pricing

No surprise or hidden fees when you get your invoice. We ensure you always know exactly what you’re paying for before any work starts.

Timely Service

When you call us, you can expect timely responses to your HVAC or water heater requests & on-time arrivals to your home.

Over 2k Google Reviews

With over 2k five-star Google reviews, you know you can trust us with any heating, cooling, or water heater services.

Your Local Experts

As a locally operated business, we’ve been proud to serve the Cleveland, OH, community for nearly 100 years.

Unmatched Warranties & Guarantees

You can trust that we will always provide warranties and guarantees for our services in writing.

Review Image
Our Reviews See What Your Neighbors Are Saying

Ist time using this company, very satisfied with their job! From scheduling to finish installation just within 2 days, Efficient and seamless. Jacob did the diagnostic test, giving me sufficient info for me to make decision. Eric did consult and helped me getting a good deal.…

Lianqiao Z

Lianqiao Z

I had an excellent experience with every person I interacted with when I got my furnace replaced and AC unit installed. Scheduling was easy, Malcolm offered a great deal, and Skip and Jamal left the area pristine after installation. Truly can’t recommend enough!

Anelise H.

Anelise H.

I put a request to have a diagnostic done and the rep was there within the hour. Professional and nice! Spoke in a way I understood all and even helped with a side issue for the HVAC system he was not here for! Would highly recommend…

Brian T.

Brian T.

I recently had the pleasure of having Mike O. from PK Wadsworth visit my home for an AC check-up. Even though I mistakenly overlooked our 8 am appointment, Mike showed immense patience and kindness, waiting outside for 20 minutes. Once the visit began, his friendly demeanor,…

Aaron B.

Aaron B.

P.K. Wadsworth is an excellent HVAC service company. All communication is extremely helpful to include a service call reminder email with the technician’s photo. I opted for the Preferred Service Plan which has many benefits. I have had the Spring and Winter (had this done a…

Denise

Denise