Reliable heating, air conditioning, and water heater services are essential for maintaining the health and comfort of both residential and commercial spaces. P.K. Wadsworth Heating & Cooling has been serving the resilient community of Cleveland for over 85 years, providing top-notch services to ensure these systems function efficiently.
Whether you’re a home or business owner, having economical heating and cooling systems is critical, especially when you would rather be enjoying a Cleveland Browns game or visiting The Cleveland Museum of Art. Our goal is to get your HVAC systems and water heater up and running so you can focus on what matters most.
Contact P.K. Wadsworth Heating & Cooling today for reliable HVAC, plumbing, and water heater services in Cleveland, OH.

Air Conditioning & Cooling Services
When temperatures rise, having a dependable air conditioning system is vital. We offer a wide range of cooling services to keep you comfortable.
- Installation and replacement: We can remove your old unit and install the new one, ensuring optimal performance.
- Repair and maintenance: Our expert technicians are available for repairs and regular maintenance to keep your AC running smoothly.
- Ductless mini-splits: Ideal for residences without ductwork, these systems offer flexible and efficient cooling solutions.
- Heat pumps: These versatile systems provide heating and cooling, offering year-round comfort.
Same-Day Heating Repair & Replacement Services
A functioning heating system is crucial to keep you warm during Cleveland’s cold months, which can reach the mid-20s. Our comprehensive heating services include:
- Installation and replacement: We install and replace heating systems, ensuring they meet your needs and preferences.
- Repair and maintenance: Our skilled technicians perform repairs and maintenance to keep your heating system operating effectively.
- Gas, electric, and oil furnaces: We service various types of furnaces to provide reliable and efficient heating solutions.
- Boilers: Our boiler experts specialize in installation, replacement, repair, and maintenance to ensure consistent warmth throughout your home.
Indoor Air Quality Services in Cleveland
Indoor air quality affects every aspect of our lives, especially for individuals with lung conditions like asthma. We offer several air quality services to ensure the best air quality in your home.
- Air purifiers: These devices remove contaminants from the air, providing a cleaner and healthier environment.
- Air scrubbers: Air scrubbers reduce airborne particles and pollutants, improving indoor air quality.
- Humidifiers: Adding moisture to the air, humidifiers help alleviate dry air problems and enhance comfort.
- Dehumidifiers: These systems remove excess moisture, preventing mold growth and maintaining a comfortable indoor climate.
Top-Rated Water Heater & Plumbing Services
When your water heater begins to struggle, it can be a hassle, with water damage spreading quickly in some cases. Our knowledgeable team of technicians provides a range of plumbing services, including but not limited to:
- Installation and repair
- Water heaters and tankless water heaters
- Expansion tank services
- Leak detection
- Drain cleaning
- Gas line plumbing
- Sump and well pump services
Choose P.K. Wadsworth Heating & Cooling in Cleveland, OH
P.K. Wadsworth Heating & Cooling has been a leading name in the home service industry for over 85 years. As a family-owned and -operated business, we provide exceptional service with trained and certified technicians. Our team is known for being on-time and reliable, offering same-day services and maintenance plans to keep your systems in top condition. With over 32,000 five-star reviews from satisfied customers, you can trust us for all your HVAC and plumbing needs. We offer upfront and instant pricing, ensuring no hidden costs.
Schedule service with P.K. Wadsworth Heating & Cooling today for top-rated HVAC, water heater, and plumbing services in Cleveland, OH.
Recent Jobs and Reviews in Cleveland, OH
Job Locations and Reviews
Performed HVAC service call on air conditioning system. Inspected air handler unit and condensate drainage system. Found standing water in drain pan with visible staining and discoloration indicating drainage issues. Examined PVC condensate line configuration with trap assembly. Noted significant rust-colored mineral deposits and water staining on drain pan surface. Documented moisture accumulation and high humidity conditions within cabinet. Tested and evaluated drainage components including trap assembly and discharge piping. System components assessed for proper operation and water removal functionality.
# HVAC Cooling Maintenance Completed
Performed comprehensive cooling season maintenance on residential HVAC system consisting of Lennox furnace unit with integrated air handler. Conducted thorough inspection of all accessible mechanical and electrical components within both units. Verified proper operation of blower motor assembly, examined gas valve components, and inspected all electrical connections including capacitors and pressure switches for signs of wear or deterioration.
Evaluated condition of pleated air filters in air handler compartment and confirmed adequate airflow through system. Inspected flexible metal ductwork connections for proper sealing and structural integrity. All safety labels and manufacturer specifications were reviewed to ensure compliance with operational standards. System components showed normal wear consistent with age of installation, with no immediate service concerns identified. Unit remains in functional operating condition for continued cooling s
Completed cooling system tune-up on residential HVAC unit. Performed temperature diagnostics at supply duct measuring 58.4°F and electrical measurements at outdoor condensing unit showing 69.9V and 11.1A readings, confirming proper system operation and airflow performance.
Replaced failed thermostatic expansion valve (TXV) on HVAC system under limited warranty coverage. Connected manifold gauges to verify proper refrigerant charge and system operation following component replacement, with temperature readings confirming system restored to normal operating parameters.
Responded to service call for air conditioning system not maintaining desired temperature at thermostat setpoint. Upon arrival, found 20-year-old outdoor condensing unit with aged electrical components showing significant wear and weathering. Performed diagnostic evaluation of system operation and inspected electrical connections including contactor and run capacitor. Documented condition of electrical components with photographs showing deteriorated wiring insulation, dust accumulation, and aged capacitor with faded labeling. Confirmed best contact number for follow-up communication regarding system performance and repair recommendations for aging equipment.
Completed first-year preventive maintenance on residential cooling system under MVP agreement. Performed comprehensive system inspection including electrical measurements, compressor diagnostics using CoreSense equipment for Copeland scroll compressor, and capacitor testing. All components operating within normal parameters; no deficiencies found requiring immediate attention.
Provided comprehensive estimate for complete HVAC system replacement including furnace and air conditioning unit for residential property with balcony access and elevator availability. Evaluated existing split system configuration with indoor furnace located in utility closet and outdoor condensing unit positioned on concrete pad in landscaped side yard area. Presented two replacement options: standard full system replacement and premium Unico high-velocity heat pump system to address customer's heating and cooling needs.
Responded to emergency service call for non-operational air conditioning system. Performed diagnostic testing using manifold gauge set to measure refrigerant pressures on outdoor condenser unit, identifying system performance issues. Documented equipment conditions and pressure readings for service records.
Completed comprehensive cooling system maintenance on Trane XR condenser unit. Replaced heavily soiled return air filter showing significant dust and debris accumulation. Inspected outdoor unit, verified proper operation of condenser fan, and confirmed system components in good working condition.
Completed installation of heat pump system with air handler. Installed new electrical disconnect box with proper conduit routing to outdoor unit, verified 25A Class RK5 fuse protection in disconnect assembly, and ensured all electrical connections met code requirements for safe system operation.
Completed full HVAC system installation including 96% efficiency gas furnace and air conditioning condenser unit. Installed new outdoor condenser on concrete pad against exterior wall with proper clearances, connected refrigerant lines, and established electrical connections. Set condensate drain line with PVC discharge piping. Installed matching high-efficiency furnace indoors, verified proper venting, gas connections, and electrical hookup. Charged system to manufacturer specifications, tested all safety controls, and verified proper airflow and temperature differential across both heating and cooling modes. System operational and performing to specifications.
Responded to no-cooling complaint on central air conditioning system with reported loud vibration noise and inability to maintain thermostat setpoint. Upon arrival, inspected outdoor condenser unit and indoor air handler located in attic space. Identified aging equipment with mechanical failure requiring immediate attention. Due to system age exceeding 10 years and extent of necessary repairs, recommended complete system replacement. Customer approved replacement of existing unit with new high-efficiency system. Removed old condenser unit from exterior gravel pad and disconnected indoor air handler from ductwork and refrigerant lines. Installed new outdoor condensing unit on existing concrete pad, ensuring proper leveling and clearances from structure and fence line. Mounted new air handler in attic space, connecting to existing flexible ductwork and establishing new refrigerant line set. Performed vacuum and refrigerant charge per manufacturer specifications. Tested system operation,
Responded to no cooling complaint on 21-year-old HVAC system. Evaluated existing equipment and determined system had reached end of service life. Presented replacement options to address failed cooling capacity. Documented existing electrical panel configuration and delivered new air cleaner media component for upcoming system installation.
Responded to service call for air conditioning unit cycling off after thirty seconds of operation. Upon inspection, found heavy frost and ice buildup on suction line and compressor, indicating restricted refrigerant flow or low charge condition. Performed diagnostic testing with multimeter to verify system operation and electrical components. Identified refrigerant system issue causing inadequate cooling and short cycling. Documented conditions with photographs showing frosted refrigerant lines, compressor assembly, and internal cabinet components for service records.
Responded to no power call at rental property where tenant reported loss of electrical power and blinking thermostat. Upon arrival, inspected electrical system and identified issues with ceiling-mounted track lighting fixtures showing signs of loose connections and potential electrical faults at mounting points. Examined ceiling fixtures with discoloration indicating possible previous moisture exposure that may have compromised wiring integrity. Secured all electrical connections at fixture mounting points, verified proper grounding, and restored power to affected circuits. Tested thermostat functionality and confirmed restoration of normal operation. All systems operational upon completion.
Performed comprehensive preventive maintenance on residential HVAC system with equipment over 10 years old in preparation for cooling season. Inspected Comfort-Aire furnace and air conditioning unit, examining all internal components including capacitor, electrical connections, and blower assembly. Cleaned accumulated dust and debris from interior compartments, checked all wire connections and terminals for proper contact, verified capacitor function, and inspected refrigerant lines and condensate drainage system for proper operation.
Installed dedicated 20-amp circuit for dishwasher, running new wiring from main electrical panel through utility space and wall access point to kitchen appliance location. Circuit includes appropriate GFCI protection and meets current electrical code requirements for dishwasher installations.
Completed routine cooling system maintenance inspection as part of ongoing preventive maintenance program. Performed comprehensive system evaluation, checked temperature readings at 67.82°F, and inspected all accessible equipment components. No deficiencies or abnormalities were identified during the inspection. Serviced electrical connections and verified proper system operation throughout the unit.
Completed full HVAC system installation including 96% efficiency furnace and air conditioning system. Rigging equipment was utilized to hoist outdoor condensing unit 10-15 feet to rooftop location. Post-installation testing performed using digital manometer to verify proper static pressure readings across the system, with measurements showing 0.39 inWG and -0.61 inWG differential. New galvanized ductwork installed in basement mechanical room with proper connections and transitions to existing infrastructure.
Responded to no cooling complaint and found evaporator coil completely frozen with significant ice buildup on refrigerant lines and valve assembly. Diagnosed restricted airflow due to severely clogged air filter and dirty evaporator coil fins. Shut down system to allow ice to thaw, replaced air filter, and cleaned evaporator coil. System restored to normal operation with proper airflow and cooling capacity.