Reliable heating, air conditioning, and water heater services are essential for maintaining the health and comfort of both residential and commercial spaces. P.K. Wadsworth Heating & Cooling has been serving the resilient community of Cleveland for over 85 years, providing top-notch services to ensure these systems function efficiently.
Whether you’re a home or business owner, having economical heating and cooling systems is critical, especially when you would rather be enjoying a Cleveland Browns game or visiting The Cleveland Museum of Art. Our goal is to get your HVAC systems and water heater up and running so you can focus on what matters most.
Contact P.K. Wadsworth Heating & Cooling today for reliable HVAC, plumbing, and water heater services in Cleveland, OH.

Air Conditioning & Cooling Services
When temperatures rise, having a dependable air conditioning system is vital. We offer a wide range of cooling services to keep you comfortable.
- Installation and replacement: We can remove your old unit and install the new one, ensuring optimal performance.
- Repair and maintenance: Our expert technicians are available for repairs and regular maintenance to keep your AC running smoothly.
- Ductless mini-splits: Ideal for residences without ductwork, these systems offer flexible and efficient cooling solutions.
- Heat pumps: These versatile systems provide heating and cooling, offering year-round comfort.
Same-Day Heating Repair & Replacement Services
A functioning heating system is crucial to keep you warm during Cleveland’s cold months, which can reach the mid-20s. Our comprehensive heating services include:
- Installation and replacement: We install and replace heating systems, ensuring they meet your needs and preferences.
- Repair and maintenance: Our skilled technicians perform repairs and maintenance to keep your heating system operating effectively.
- Gas, electric, and oil furnaces: We service various types of furnaces to provide reliable and efficient heating solutions.
- Boilers: Our boiler experts specialize in installation, replacement, repair, and maintenance to ensure consistent warmth throughout your home.
Indoor Air Quality Services in Cleveland
Indoor air quality affects every aspect of our lives, especially for individuals with lung conditions like asthma. We offer several air quality services to ensure the best air quality in your home.
- Air purifiers: These devices remove contaminants from the air, providing a cleaner and healthier environment.
- Air scrubbers: Air scrubbers reduce airborne particles and pollutants, improving indoor air quality.
- Humidifiers: Adding moisture to the air, humidifiers help alleviate dry air problems and enhance comfort.
- Dehumidifiers: These systems remove excess moisture, preventing mold growth and maintaining a comfortable indoor climate.
Top-Rated Water Heater & Plumbing Services
When your water heater begins to struggle, it can be a hassle, with water damage spreading quickly in some cases. Our knowledgeable team of technicians provides a range of plumbing services, including but not limited to:
- Installation and repair
- Water heaters and tankless water heaters
- Expansion tank services
- Leak detection
- Drain cleaning
- Gas line plumbing
- Sump and well pump services
Choose P.K. Wadsworth Heating & Cooling in Cleveland, OH
P.K. Wadsworth Heating & Cooling has been a leading name in the home service industry for over 85 years. As a family-owned and -operated business, we provide exceptional service with trained and certified technicians. Our team is known for being on-time and reliable, offering same-day services and maintenance plans to keep your systems in top condition. With over 32,000 five-star reviews from satisfied customers, you can trust us for all your HVAC and plumbing needs. We offer upfront and instant pricing, ensuring no hidden costs.
Schedule service with P.K. Wadsworth Heating & Cooling today for top-rated HVAC, water heater, and plumbing services in Cleveland, OH.
Recent Jobs and Reviews in Cleveland, OH
Job Locations and Reviews
Responded to no cooling call on recently installed system. Performed initial diagnostic measurements using clamp meter to verify electrical readings. Determined unit requires proper startup procedure to be completed. Scheduled return visit to perform full system startup and commissioning to restore cooling operation.
Conducted comprehensive HVAC system evaluation for residential property with existing 2010 Carrier furnace installation. Assessed current heating system condition, evaluated ductwork infrastructure showing age-related wear and dust accumulation, and provided complete system replacement options including add-on air conditioning configurations. Documented existing basement mechanical room layout with measurements and prepared detailed proposal drawings outlining equipment placement, venting requirements, and system specifications for full HVAC system upgrade to address aging equipment concerns.
Completed geothermal HVAC system installation in residential mechanical room, including integration with existing infrastructure. System features modern geothermal heat pump unit with proper electrical specifications and safety labeling, coordinated with dual tankless water heaters, expansion tank, and air handler with refrigerant line connections. All equipment installed on protective floor pads with appropriate copper piping, PVC drainage, and electrical conduit routing per manufacturer specifications and code requirements.
Responded to no cooling call at rental property. Upon arrival, connected manifold gauge set to outdoor condensing unit to diagnose system failure. Performed pressure readings on both low and high pressure sides of the refrigerant circuit to assess system operation and identify cause of complete system shutdown on approximately 10-year-old residential air conditioning unit.
Completed comprehensive cooling season tune-up on Amana outdoor condensing unit. Performed standard maintenance protocol including inspection of electrical connections, capacitor testing, refrigerant pressure verification, coil cleaning assessment, and operational safety checks. Unit found operating within normal parameters with all components functioning properly; no repairs required at this time.
Completed comprehensive cooling system tune-up on residential HVAC unit. Performed full system inspection including electrical control panel examination, verified proper operation of CoreSense diagnostic system for compressor monitoring, checked all wire connections and terminals for secure contact, tested capacitor functionality, and inspected contactor relay operation. Outdoor condensing unit inspected for proper airflow through top grille and verified all access panels secure. System operating within normal parameters upon completion.
Responded to service call for dual-zone system with upstairs unit failing to maintain temperature. Performed diagnostic evaluation of both HVAC units, with upstairs zone showing inadequate cooling performance compared to downstairs unit. Utilized refrigerant charging scale to assess and verify system refrigerant levels, ensuring proper charge for optimal operation and resolving temperature differential issues between zones.
Performed comprehensive cooling season tune-up on residential air conditioning system. Conducted electrical measurements using digital clamp meter, recording temperature readings at condenser unit which showed 45.7°C. Inspected outdoor condenser unit with green metal housing, noting dust and debris accumulation on coil fins requiring attention during routine maintenance service.
Responded to service call for air conditioning system maintenance. Replaced air filter with correct size filter as requested and activated cooling system for operation. Verified unit startup and confirmed proper system function using diagnostic equipment.
Completed scheduled preventive maintenance on residential cooling system. Inspected and cleaned return air grille which showed significant dust and debris accumulation that was restricting airflow. Performed standard system inspection including verification of operational components and airflow pathways to ensure optimal cooling performance for continued seasonal operation.
Responded to no cooling complaint on Comfortmaker EnviroPlus 90 furnace system. Addressed and resolved rodent infestation issue that was affecting system operation. System inspected and verified operational following pest remediation.
Completed comprehensive cooling season tune-up on Daikin outdoor condensing unit, including inspection of electrical disconnect, refrigerant line connections, and drainage system. All components found operating within manufacturer specifications, with unit ready for optimal summer performance.
Responded to report of condensate pump running continuously. Inspected HVAC system and documented equipment serial number with photographs for warranty filing purposes. Assessed condensate pump operation and system components to determine cause of continuous runtime.
Completed routine cooling system maintenance as part of ongoing preventive maintenance program. Performed comprehensive inspection of air handler unit located in attic space, measuring supply air temperature at 52.5°F to verify proper cooling operation. Conducted electrical diagnostics using clamp meter, recording amperage draw of 0.12A and voltage reading of 27.50V to confirm system components operating within manufacturer specifications. Inspected ductwork, insulation, and air handler cabinet for proper condition and secure connections. All measurements indicate system functioning correctly with no deficiencies noted.
Responded to no-cool call on recently installed 2-day-old system with indoor temperature in the 80s. Upon inspection, discovered extensive frost and ice buildup throughout the evaporator coil compartment, indicating improper refrigerant charge or airflow restriction from installation. Found wiring issues from initial installation that caused intermittent fan operation. Corrected improper electrical connections that installers had attempted to troubleshoot. Addressed incomplete installation work including unfinished thermostat installation. Verified proper system operation, airflow, and refrigerant charge after corrections were made to restore cooling capacity.
Responded to no cooling complaint on residential air conditioning unit. Upon inspection, discovered access panel open with significant accumulation of nesting material (white fibrous debris) in electrical compartment surrounding capacitor and internal wiring connections. Removed foreign material from unit, verified electrical connections secure, and restored system to proper operation.
Performed comprehensive air conditioning tune-up on Lennox condensing unit model C35-24B-2F-20 as part of scheduled maintenance plan. Conducted complete system inspection including refrigerant charge verification, electrical connections, condenser coil cleaning, and operational testing of all components. System found operating within manufacturer specifications with no deficiencies noted; confirmed proper drainage through condensate system and verified all safety controls functioning correctly.
Responded to no cooling complaint following previous circuit board replacement. Performed system diagnostics and airflow measurements at supply registers to verify proper operation and determine if additional repairs were needed beyond the control board that was recently installed.
Conducted comprehensive inspection and assessment of existing electrical panel for whole home surge protection and AC surge protection installation. Evaluated main service panel containing dual-column circuit breaker configuration with organized wire management and documented current electrical distribution system layout. Photographed panel interior showing main disconnect, branch circuit arrangement, and existing grounding configuration to develop accurate equipment specifications and installation requirements for surge protective devices.
Completed scheduled preventive maintenance on Goodman cooling system. Performed comprehensive inspection of air handler and condensing unit, verified refrigerant charge and system temperatures with digital thermometer reading 5.0°F temperature split, checked electrical connections and controls, inspected ductwork and drainage components including PVC condensate lines, and confirmed all safety devices functioning properly. System operating within manufacturer specifications with no deficiencies noted.