Pepper Pike, OH, is a vibrant community with lots to love. Its location only about 30 minutes outside of Cleveland also makes it a prime destination for those looking for a home close to the city but not too close.
To keep your Pepper Pike, OH, home functioning at its best, you can trust P.K. Wadsworth Heating & Cooling. Our company offers residential and commercial plumbing and HVAC services. Whether your home’s AC won’t work or your business has a clogged drain, we can help.
Contact us now to schedule an appointment with the P.K. Wadsworth Heating & Cooling team.

Air Conditioning & Cooling Services
Is your AC system having issues? Don’t wait to get it checked out. P.K. Wadsworth Heating & Cooling offers cooling services, such as AC installation, replacement, repair, and maintenance.
Ductless Mini-Splits
A ductless mini-split unit is great for cooling small areas such as apartments or single rooms. If you want to add one to your home, contact us ASAP. We’ll handle the installation from start to finish.
Heat Pumps
Heat pumps can act as a heater and an AC unit for your home. Our technicians have the knowledge and skills to keep your heat pump in peak condition, whether it needs some maintenance or a lengthy repair.
Heating Repair & Replacement Services
You can’t afford to face the cold months without a reliable heater. Our skilled team provides all kinds of heating services, including installation, replacement, repair, and maintenance services. No matter what’s wrong with your heater, you can trust us to troubleshoot and get the heat flowing in your home again.
Furnaces
The furnace is one of the most common home heaters in Pepper Pike, OH. That’s why the P.K. Wadsworth Heating & Cooling team is highly skilled at working with gas, electric, and oil furnaces. We can fix your old furnace or install a new one if necessary.
Boilers
Boilers are another common way to heat houses, but unlike other heaters, they use water and steam to generate heat. Boilers can have unique issues that make them hard to service, so you want to hire a company that knows how to handle them. P.K. Wadsworth Heating & Cooling’s boiler experts can quickly handle your boiler repair or replacement work.
Indoor Air Quality Services in Pepper Pike
Is the air in your home clean? If you’ve never taken advantage of our air quality services, then maybe not. We can help you get clean, high-quality air in your home with products like:
Comprehensive Water Heater & Plumbing Services
P.K. Wadsworth Heating & Cooling is here for all your plumbing service needs. We can handle minor issues like clogged drains and major issues like water heater repairs. We can work on both traditional and tankless water heaters, so don’t hesitate to reach out if you notice problems with your unit.
Trust P.K. Wadsworth Heating & Cooling In Pepper Pike
P.K. Wadsworth Heating & Cooling is a trustworthy business in Pepper Pike, OH, for good reason. Your neighbors rely on us for their HVAC needs because:
- We put customer satisfaction first: We have over 32,000 five-star reviews to prove it.
- We’re experienced: Our family-owned and -operated business has been helping customers for over 85 years.
- We’re trained: Our certified technicians have what it takes to handle various HVAC- or plumbing-related problems.
Contact us now to find out what P.K. Wadsworth Heating & Cooling can do for you.
Recent Jobs and Reviews in Pepper Pike, OH
Job Locations and Reviews
Conducted comprehensive estimate evaluation for furnace replacement in residential property. Assessed existing brown/tan metal furnace unit with side-mounted humidifier system, documented current thermostat configuration (White-Rodgers digital unit), and evaluated overall HVAC system layout including existing ductwork and mechanical room conditions. Provided homeowner with multiple furnace replacement options based on equipment age, configuration, and space requirements.
Completed installation of new air conditioning system in basement utility area. Installed air handler unit with associated electrical connections and conduit work, configured PVC venting system in U-shaped configuration for proper intake and exhaust, and connected sheet metal ductwork to integrate with existing furnace system. All equipment mounted on concrete floor per manufacturer specifications, electrical components properly wired and secured, and system tested for proper operation upon completion.
Completed scheduled preventive maintenance on Carrier cooling system. Performed comprehensive inspection of indoor air handler unit, including electrical components and capacitor functionality. Verified refrigerant line connections, insulation integrity, and all electrical terminations at dual-run capacitor (45/7.5μF, 440VAC). All system components operating within manufacturer specifications with no deficiencies noted.
Completed scheduled preventive maintenance on residential cooling system. Performed comprehensive electrical diagnostics using clamp meter to verify amperage draw and voltage readings at outdoor unit, confirming proper compressor operation and electrical performance within manufacturer specifications. Inspected control board wiring connections, terminal blocks, and low-voltage thermostat circuits for secure connections and proper function. All system components operating normally with no deficiencies noted.
Completed comprehensive cooling system tune-up on residential HVAC unit. Inspected and serviced all major components including condenser unit, evaporator coil, and electrical connections. Noted significant corrosion on capacitor terminals and mounting hardware, indicating prolonged moisture exposure; capacitor remains functional but will require monitoring for future replacement. Verified system airflow, checked refrigerant levels, cleaned accessible components, and confirmed proper operation of all safety controls and thermostat functionality.
Conducted on-site assessment of existing HVAC system in basement utility area to provide replacement options for air conditioning equipment. Evaluated current furnace and air handler configuration, noting accessible installation location with adequate clearance for equipment service and replacement. Documented existing ductwork assembly, PVC drainage lines, and ventilation routing to determine compatibility requirements for new AC system integration. Photographed current equipment layout showing furnace unit, wrapped ductwork, horizontal and vertical PVC piping with proper mounting supports, and surrounding mechanical components. Prepared two AC replacement options tailored to the straightforward access conditions and existing infrastructure, accounting for the organized installation space and proper support structures already in place.
Returned to site to replace defective air scrubber UV bulb as scheduled. Removed existing contaminated filter assembly from air purification unit, installed new UV lamp component, and reassembled system to restore proper air sanitization functionality.
Responded to no cooling complaint and conducted system evaluation. Assessed outdoor condensing unit and indoor furnace/coil assembly to provide replacement options for failed air conditioning system. Documented existing equipment configuration including furnace installation and exterior condensing unit location for estimate preparation.
Completed scheduled preventive maintenance on two outdoor HVAC cooling systems. Performed comprehensive inspection of electrical components including capacitors, contactors, and wiring connections on both units. Tested system operation and verified all connections were secure with no signs of electrical issues requiring immediate attention.
Completed scheduled preventive maintenance on residential cooling system. Performed comprehensive inspection of outdoor condensing unit and indoor control board assembly, verifying proper operation of all electrical components, connections, and control circuits. Documented system condition with photographs showing control board functionality and exterior equipment installation for maintenance records.
Responded to no-cooling call and performed diagnostic inspection of residential air conditioning system. Verified furnace and indoor air handler operation in basement, confirmed proper electrical connections and ductwork integrity. Inspected outdoor condenser unit, checked fan assembly and motor operation, and verified unit returned to normal cooling function. System tested and confirmed operational upon completion.
Responded to low water pressure complaint with rambling sounds from faucets in 56-year-old home with well water system. Inspected basement water treatment equipment including dual water softener/filtration tanks with digital control heads and pressure tank assembly. Diagnosed pressure irregularities in the well system plumbing network. Checked pressure gauge readings, examined piping connections between water heater and treatment tanks, and verified proper operation of softener control valves. Adjusted system settings and cleared air from lines to restore adequate water pressure and eliminate noise at fixtures throughout the home.
Responded to no cooling call at residential property. Upon arrival, found thermostat displaying but system not responding to cooling commands. Removed thermostat from wall plate to inspect wiring connections and verify proper 24V power supply. All wiring connections were secure and voltage readings confirmed adequate power to thermostat. Determined thermostat had failed and was not sending call signal to outdoor condensing unit. Discussed replacement options with homeowner and temporarily removed faulty thermostat for customer review of upgrade options before reinstallation of new unit.
Replaced failed contactor and weak capacitor on HVAC system to restore proper compressor operation. Performed complete system cleaning on both indoor and outdoor units, removing accumulated dust and debris from evaporator coil, condenser coil, and all accessible components to improve efficiency and airflow.
Performed comprehensive electrical inspection of commercial control system and main distribution panel. Documented contactor panel installation featuring centralized relay device with multi-phase wiring connections, yellow crimp terminals, and proper cable management. Verified integrity of electrical connections including red, black, white, and tan conductors routed through conduit and flexible metal whip. Inspected main electrical panel containing dual columns of circuit breakers with mixed individual and bundled conductor wiring, confirming proper wire nut connections and organized circuit arrangements. All components photographed for service records.
Completed cooling maintenance on outdoor condensing unit. Performed electrical diagnostics using clamp meter, recording compressor amperage at 15.02 amps. Inspected condenser coils, fan assembly, and electrical connections. Unit operating within normal parameters at time of service.
Responded to no cooling call on 1-year-old HVAC unit. Upon arrival, performed diagnostic evaluation to identify cause of system failure. Conducted thorough inspection of thermostat operation, electrical components, and refrigerant circuit. Identified and resolved issue preventing cooling operation. System restored to proper cooling function and verified all equipment operations before departure.
# HVAC Service Call - No Cooling Condition
Responded to service call for central air conditioning system with no cooling capability. Upon arrival, customer reported complete loss of cooling function with system age unknown.
## Diagnostic Procedures
Performed comprehensive system evaluation of residential split-system air conditioning unit located in interior mechanical closet. Conducted visual inspection of air handler cabinet and associated components. Examined electrical connections at junction box and verified whip connector integrity to unit. Inspected condensate drain lines and refrigerant line connections at base of air handler.
Evaluated ductwork connections and flexible duct routing from air handler. Checked system labels and manufacturer specifications on equipment panels. Assessed overall condition of installation including clearances and accessibility in confined mechanical space.
## Findings
System inspection revealed air handler unit in mechanical closet with standar
Completed removal of Moen faucet unit from residential plumbing system as requested. All connections were properly disconnected and the unit was safely extracted from the installation without damage to surrounding copper piping or water system components.
Responded to no cooling call on aging HVAC system. Upon arrival, confirmed unit was running but not producing cool air. Opened air handler access panel to inspect internal components, checked electrical connections, blower motor assembly, and wiring. Examined refrigerant lines, condensate drain system with PVC T-junction and copper drain extension, and verified proper drainage function. Documented system condition with photos showing air handler configuration, ductwork connections, and drainage components for service records.