P.K. Wadsworth Heating & Cooling has kept Shaker Heights homeowners comfortable since 1936. We’re experts in climate control who have consistently earned the loyalty and trust of customers by exceeding expectations with best-in-class technicians, reliable service, and custom solutions.
Whether it’s through our preventative maintenance plans, installation of heating and cooling systems, or efficient and effective HVAC repair throughout Shaker Heights, our flexibility, professionalism, industry knowledge, and friendly staff have made all the difference for more than 80 years.
Contact our local HVAC company for repair, replacement, and maintenance services in the Shaker Heights, Ohio area.
Heating Services In Shaker Heights

P.K. Wadsworth is the leading HVAC company in Cleveland, providing heating services in Shaker Heights. From heating system repair to replacement, we’ll perform necessary tasks to keep your system in prime condition while providing you the peace of mind that your home heating is as reliable, safe and efficient as possible. P.K. Wadsworth offers the following heating services:
- Furnace installation
- Furnace replacement
- Furnace maintenance
- Furnace repair
- Boiler installation
- Boiler replacement
- Boiler maintenance
- Boiler repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
Contact us to schedule top-rated heating services, such as furnace repair, heating replacement, and heating installation in Shaker Heights!
Air Conditioning Services In Shaker Heights
With P.K. Wadsworth, an HVAC technician will assess your Shaker Heights home, budget, and comfort preferences. In order to keep you and your family comfortable—even when the temperatures are reaching record highs—we offer the following air conditioner services in Shaker Heights:
- Air conditioner installation
- Air conditioner replacement
- Air conditioner maintenance
- Air conditioner repair
- Ductless system installation
- Ductless system replacement
- Ductless system maintenance
- Ductless system repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
- Contact our local HVAC company to schedule air conditioner services, such as AC repair, replacement, and maintenance in Shaker Heights!
Indoor Air Quality In Shaker Heights, Ohio

Many people are surprised to learn that indoor air can be many times more polluted than outdoor air. That’s because most buildings today are sealed tight to keep heated and cooled air from leaking out. Although this conserves energy, it can create indoor air that’s infested with invisible pollutants that adversely affect health and well-being. Keep the air quality in your Shaker Heights home as clean as possible with our top-rated indoor air quality services.
When you need indoor air quality services in Shaker Heights, there’s only one name you need to know—P.K. Wadsworth.
Choose P.K. Wadsworth As Your Shaker Heights HVAC Company
P.K. Wadsworth has one of the most experienced HVAC companies in Shaker Heights, Ohio. All of our heating and cooling professionals are trained and certified to work on most heating and air conditioning systems, regardless of the brand. From heating replacement to AC repair in Shaker Heights, you can trust our team to get the job done right.
Contact our local HVAC company to schedule heating or air conditioning services throughout Shaker Heights—including AC or furnace repair, HVAC replacement, and HVAC maintenance.
Recent Jobs and Reviews in Shaker Heights, OH
Job Locations and Reviews
Completed heating tune-up for new homeowner, performing comprehensive system inspection and combustion analysis on natural gas furnace. Verified proper combustion efficiency with oxygen levels at 7.9%, carbon monoxide readings at 32 PPM, and stack temperature at 350°F, all within acceptable parameters. Documented all equipment specifications and serial numbers for maintenance tracking program enrollment.
Completed routine heating maintenance on boiler system and inspected all operational components. Identified and documented issue with automatic water feeder not activating properly, which will require further attention to prevent low water conditions and potential system damage.
Eliminated prohibited saddle valve connection on humidifier water supply line and replaced with code-compliant plumbing installation. Removed non-approved joints and fittings, ensuring all connections meet current mechanical code requirements. Documented all modifications with photographs showing exterior drainage components and foundation area where work was performed.
Completed comprehensive HVAC system installation including steam-to-hot water boiler conversion with new piping infrastructure, Unico air handler with ductwork installed in attic space, hot water heating loop with panel radiators, and mini split system. All mechanical systems commissioned and operational with copper supply lines properly connected throughout residence.
Completed installation of new air conditioning system and evaporator coil at residential property. System included ALXS3BN3010 unit with exterior condenser placement on side of building, proper electrical connections via conduit and dedicated disconnect box mounted to vinyl siding, and refrigerant line set routing along exterior wall foundation. All components tested and operational upon completion.
Completed routine afternoon maintenance on residential boiler system. Performed comprehensive inspection of heating unit, expansion tank, pressure relief valves, and associated piping connections. Verified proper operation of all controls, checked pressure gauge readings, and examined condition of insulation materials. All components found to be functioning within normal parameters. System operational and ready for continued service.
Completed comprehensive heating system maintenance on furnace unit. Performed full system inspection with interior access panel removed to examine all internal components, electrical connections, and wiring harnesses. Verified proper operation of control board with LED indicators functioning correctly, inspected PVC condensate and vent piping connections at unit, and confirmed all wire bundles and electrical connections were secure throughout the system. Unit tested and operating within normal parameters.
Completed first-year preventive maintenance on residential heating system. Performed comprehensive inspection of furnace components including blower motor assembly, electrical connections, and control board wiring. Verified system pressures using calibrated digital gauge, confirming proper operational parameters at 190 PSI. All colored wiring connections inspected and found secure with no signs of wear or damage. System tested and operating within manufacturer specifications.
Conducted on-site assessment of existing boiler system in basement mechanical room to provide replacement options. Evaluated current piping configuration, including galvanized steel and copper supply lines, shutoff valves, and distribution system. Documented existing installation conditions and spatial requirements for new boiler equipment recommendations.
Completed comprehensive heating maintenance on two HVAC systems. Performed thorough inspection of furnace components including draft inducer blower motor assemblies, electrical connections, and wiring harnesses. Verified proper operation of all mechanical systems, checked blower motors, examined combustion chambers, and inspected ventilation piping. All electrical connections were secure with proper wire management in place. Both heating units tested and confirmed operational with no deficiencies noted.
Completed scheduled HVAC heating maintenance on boiler system, performing comprehensive inspection of all components including piping, connections, and control systems. Documented system condition with diagnostic measurements using clamp meter, inspected sight glass showing sediment accumulation, and examined copper piping exhibiting corrosion and mineral deposits requiring monitoring. Verified all PVC piping, ball valves, and connections for proper operation and confirmed system functionality upon completion.
Conducted comprehensive electrical panel assessment for estimate purposes. Documented existing 200-amp main service panel installation, photographed internal breaker configuration showing dual-row circuit breaker arrangement with associated branch circuit wiring, and evaluated exterior meter base connection with PVC conduit routing along foundation. Assessed panel capacity, wiring conditions, and service entrance components to provide accurate replacement quotation.
Removed and replaced a 12-inch section of leaking steam pipe located above the forced air system following professional asbestos abatement. Coordinated repair work with 45-minute lead time after hazardous material removal was completed. Successfully restored steam pipe integrity and ensured proper operation of the system.
Completed comprehensive preventative maintenance service on residential HVAC system including both furnace and air conditioning units. Performed full inspection of gas furnace, including blower motor assembly, heat exchanger, control board, and all electrical connections. Verified proper operation of all safety controls and components. Conducted thorough maintenance on air conditioning system, inspecting refrigerant lines, ductwork connections, and associated mechanical components. All equipment found to be in good operating condition with no issues identified during inspection.
Completed comprehensive heating maintenance on residential HVAC system. Performed detailed inspection of burner assembly, manifold components, and heat exchanger, noting minor discoloration around burner ports consistent with normal operation. Verified proper operation of air handler unit in attic installation, confirmed all safety labels and manufacturer specifications clearly visible and intact, and ensured system components are securely mounted and functioning within normal parameters.
Conducted comprehensive electrical inspection of residential property. Evaluated main electrical panel installation containing eight fuses/circuit breakers with visible color-coded components and adjacent breaker switches. Documented panel condition and configuration through photographic evidence. Inspected basement electrical infrastructure including conduit runs, junction boxes, and panel connections. Assessed electrical system in relation to surrounding environmental conditions, noting moisture indicators on walls that could potentially impact electrical components. Verified proper mounting and accessibility of all electrical equipment. Completed visual inspection of all accessible electrical components and documented findings for record.
Completed scheduled preventive maintenance on water boiler heating system as part of ongoing recurring service plan. Inspected and verified proper operation of system pressure gauge reading approximately 20 PSI, pump control assembly with green indicator light showing active status, and associated valve components. All boiler components found operating within normal parameters with no immediate service needs identified.
Responded to no heat call where homeowner reported boiler failure potentially caused by another contractor's underground plumbing work in basement. Upon arrival, inspected blue residential boiler unit and associated electrical wiring for damage or disconnections. Verified power supply to unit, checked control wiring connections, and examined thermostat circuit for breaks or loose connections that may have occurred during excavation work. Traced electrical runs and confirmed all safety controls, limit switches, and transformer connections were intact. Restored power to boiler, verified proper ignition sequence, and confirmed unit returned to normal heating operation. Documented existing mechanical room conditions with photographs showing copper piping, gas connections, and electrical infrastructure. Unit tested successfully with no further issues noted at time of service.
# HVAC Heating Maintenance Completed
Performed annual preventive maintenance service on residential forced-air furnace system as part of scheduled maintenance program. Conducted comprehensive inspection of all major components including heat exchanger, burner assembly, blower motor, and electrical connections. Verified proper operation of safety controls and limit switches.
Replaced existing air filter with new pleated media filter to ensure optimal airflow and system efficiency. Inspected filter housing and confirmed proper seal to prevent air bypass. Cleaned accessible interior components and removed accumulated dust and debris from unit exterior and surrounding area.
Tested system startup sequence and verified ignition operation. Monitored system performance during full heating cycle to confirm proper temperature rise and airflow distribution. All components found to be operating within manufacturer specifications with no deficiencies noted. System left in full operational status
Conducted comprehensive assessment of existing HVAC infrastructure consisting of multiple Carrier heating and cooling systems located in basement mechanical room. Evaluated current multi-zone configuration with two furnace units and associated air handling equipment for potential replacement options. Customer requested comparative estimates for three replacement scenarios: two complete system replacements, two furnace replacements, and one furnace replacement as alternatives to previously quoted repair work. Documented existing equipment layout including centralized ductwork distribution, flexible and rigid duct runs, PVC condensate drainage lines, and electrical service panel configuration to support accurate replacement system specifications and installation planning.