P.K. Wadsworth Heating & Cooling has kept Shaker Heights homeowners comfortable since 1936. We’re experts in climate control who have consistently earned the loyalty and trust of customers by exceeding expectations with best-in-class technicians, reliable service, and custom solutions.
Whether it’s through our preventative maintenance plans, installation of heating and cooling systems, or efficient and effective HVAC repair throughout Shaker Heights, our flexibility, professionalism, industry knowledge, and friendly staff have made all the difference for more than 80 years.
Contact our local HVAC company for repair, replacement, and maintenance services in the Shaker Heights, Ohio area.
Heating Services In Shaker Heights

P.K. Wadsworth is the leading HVAC company in Cleveland, providing heating services in Shaker Heights. From heating system repair to replacement, we’ll perform necessary tasks to keep your system in prime condition while providing you the peace of mind that your home heating is as reliable, safe and efficient as possible. P.K. Wadsworth offers the following heating services:
- Furnace installation
- Furnace replacement
- Furnace maintenance
- Furnace repair
- Boiler installation
- Boiler replacement
- Boiler maintenance
- Boiler repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
Contact us to schedule top-rated heating services, such as furnace repair, heating replacement, and heating installation in Shaker Heights!
Air Conditioning Services In Shaker Heights
With P.K. Wadsworth, an HVAC technician will assess your Shaker Heights home, budget, and comfort preferences. In order to keep you and your family comfortable—even when the temperatures are reaching record highs—we offer the following air conditioner services in Shaker Heights:
- Air conditioner installation
- Air conditioner replacement
- Air conditioner maintenance
- Air conditioner repair
- Ductless system installation
- Ductless system replacement
- Ductless system maintenance
- Ductless system repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
- Contact our local HVAC company to schedule air conditioner services, such as AC repair, replacement, and maintenance in Shaker Heights!
Indoor Air Quality In Shaker Heights, Ohio

Many people are surprised to learn that indoor air can be many times more polluted than outdoor air. That’s because most buildings today are sealed tight to keep heated and cooled air from leaking out. Although this conserves energy, it can create indoor air that’s infested with invisible pollutants that adversely affect health and well-being. Keep the air quality in your Shaker Heights home as clean as possible with our top-rated indoor air quality services.
When you need indoor air quality services in Shaker Heights, there’s only one name you need to know—P.K. Wadsworth.
Choose P.K. Wadsworth As Your Shaker Heights HVAC Company
P.K. Wadsworth has one of the most experienced HVAC companies in Shaker Heights, Ohio. All of our heating and cooling professionals are trained and certified to work on most heating and air conditioning systems, regardless of the brand. From heating replacement to AC repair in Shaker Heights, you can trust our team to get the job done right.
Contact our local HVAC company to schedule heating or air conditioning services throughout Shaker Heights—including AC or furnace repair, HVAC replacement, and HVAC maintenance.
Recent Jobs and Reviews in Shaker Heights, OH
Job Locations and Reviews
Responded to no-cooling call on 2-month-old Amana air conditioning system. Upon arrival, confirmed thermostat was set to cool mode with fan on auto, indoor temperature at 80°F with setpoint at 70°F, but system was not initiating. Inspected outdoor condensing unit and found equipment in good physical condition with proper electrical connections at disconnect box. Diagnosed and resolved thermostat communication issue preventing system call for cooling. Verified proper system startup, confirmed compressor and condenser fan operation, and tested full cooling cycle. System now operating normally and maintaining setpoint temperature.
Returned to complete replacement of six cast iron pipe fittings in the mechanical room plumbing system. Successfully removed deteriorated cast iron elbow and connecting fittings showing significant age and corrosion, then installed new fittings to restore proper function and prevent future leaks. All connections tested and verified secure upon completion.
Completed full system replacement estimate for residential HVAC system. Assessed existing air handler installation showing signs of age with rust staining and discoloration, evaluated ductwork configuration including flexible and rigid galvanized metal ducts with Y-junction connections, and inspected basement mechanical room setup with existing thermostat control. Provided three-tier equipment options ranging from 13.4-16 SEER air conditioning units paired with 80-96% AFUE gas furnaces, all Goodman brand systems designed to replace aging equipment and improve energy efficiency.
Responded to UH error code on Daikin mini split system. Diagnosed and resolved the issue, verified proper operation with temperature readings showing 59.2°F at discharge vents. Inspected outdoor unit and condensate drainage lines to ensure system functionality and proper installation integrity.
Responded to service call for non-functioning Ring video doorbell following previous installation of two units. Performed diagnostic testing and troubleshooting on the affected doorbell, verified proper mounting and wiring connections, and restored unit to full operational status with illuminated indicator ring functioning correctly.
Performed routine cooling system maintenance on HVAC unit. Upon inspection, discovered excessive frost buildup on evaporator coils indicating potential airflow restriction or refrigerant issue. Inspected electrical components including capacitor and contactor, verified proper connections and operation of all wiring and terminals.
Responded to service call for Generac backup generator that failed to activate during neighborhood power outage. Upon arrival, performed visual inspection of unit and control panel, noting accumulation of debris and environmental contamination on exterior surfaces and electrical compartment. Inspected Eaton Cutler-Hammer Power Defense circuit breaker panel (125A rating) and internal generator control interface with maintenance schedule display. Documented current condition of unit showing weathering, dirt buildup, and operational status indicators. Unable to locate illuminated status light as reported by customer, suggesting potential control panel malfunction or power supply issue to monitoring system.
Responded to no cooling complaint on residential split system air conditioning unit. Upon arrival, customer reported system not producing cool air. Performed diagnostic evaluation of outdoor condensing unit and associated components. Documented equipment installation and current condition with photographs showing wall-mounted condenser with standard electrical disconnect, refrigerant line set, and condensate drain piping. System appears to be properly mounted and secured to exterior brick wall with appropriate clearances maintained.
Performed seasonal startup and testing on recently installed Trane air conditioning system. Conducted comprehensive inspection of outdoor condenser unit, verified electrical connections within control panel, tested Copeland compressor module operation, and confirmed proper capacitor function. System energized successfully, all components operating within manufacturer specifications, and unit ready for cooling season use.
Responded to no cooling complaint on recently installed air conditioning system unable to maintain setpoint of 70 degrees, with indoor temperature reaching 77 degrees after running continuously overnight. Performed system diagnostics and inspection of exterior refrigerant lines and electrical connections. Documentation captured of utility piping, refrigerant line set, and associated wiring at exterior wall penetration point for service records and follow-up evaluation.
Completed comprehensive furnace maintenance on a 10-year-old heating system that was operating properly at time of service. Performed full tune-up procedures including inspection of electrical connections, contactor assembly, and control components. Cleaned accumulated dust, debris, and cobwebs from electrical connection points and contactor to ensure optimal performance and prevent potential safety issues. Verified all wire connections were secure and properly terminated at terminals. Inspected outdoor condenser unit and confirmed proper clearance around equipment, noting healthy landscaping growth around perimeter that will require monitoring to maintain adequate airflow. All system components tested and operating within normal parameters upon completion of maintenance service.
Responded to emergency no cooling call on central air conditioning system less than one year old. Upon arrival, performed diagnostic inspection of outdoor condensing unit located at front of property. Visual examination revealed extensive corrosion and oxidation on refrigerant line set copper tubing and brass compression fittings at outdoor unit connections. Copper piping displayed significant darkening and patina formation indicative of moisture exposure and weathering beyond normal aging for equipment of this age. Mounting brackets and hardware showed signs of outdoor exposure deterioration. Documented corroded refrigerant line connections and compromised pipe integrity with photographic evidence for potential warranty claim consideration. System likely experiencing refrigerant loss due to compromised line set integrity at corroded connection points, resulting in loss of cooling capacity.
Conducted comprehensive evaluation of existing downstairs HVAC system for full replacement estimate. Assessed current Rheem Imperial 80 Plus heating unit, existing ductwork configuration, and mechanical room layout in basement utility area. Documented equipment specifications, clearances, and connection points including supply ductwork, electrical service, and gas piping to provide accurate replacement options for complete system upgrade.
Completed preventive maintenance on two residential HVAC cooling systems. Performed comprehensive inspection of both units including condenser coils, heat exchanger assemblies, and airflow components. First system showed clean condenser fins with proper spacing and no visible corrosion or damage to metal surfaces. Second unit exhibited normal condensation patterns on horizontal fins with minor debris accumulation between slats. Both systems operational and functioning within normal parameters. Customer will be out of the country until September and requested do not return status until further notice.
Completed preventive maintenance service on two outdoor air conditioning condenser units. Performed standard cooling season maintenance procedures including inspection of both units' electrical connections, refrigerant levels, and operational performance. All components found to be functioning within normal parameters, and both systems are operational for the cooling season.
Completed scheduled cooling system maintenance inspection in residential basement mechanical room. Performed visual assessment of HVAC equipment, ductwork connections, and associated utility infrastructure including copper refrigerant lines, galvanized ductwork, and pipe supports. Verified proper installation of mechanical components, checked insulation coverage on ceiling-mounted piping, and confirmed structural integrity of wall-mounted duct sections and pipe hangers. Documented equipment conditions through photographic records for maintenance history files.
Completed routine cooling system maintenance inspection and performance verification. Measured supply air temperature at 68°F using calibrated digital thermometer and verified electrical parameters with True RMS multimeter to ensure proper system operation. All components operating within normal specifications with no deficiencies noted during this preventive maintenance visit.
Responded to no hot water complaint at residential property. Upon arrival, inspected Bradford White Defender Safety System tanked water heater in basement utility area. Examined gas control valve and pilot assembly on unit. Found Honeywell gas control valve in OFF position. Relit pilot light following manufacturer's lighting procedures, verified proper flame characteristics, and restored gas control to operational temperature setting. Confirmed hot water restoration and proper unit function before departure.
Conducted on-site HVAC system assessment and provided replacement options for residential air conditioning equipment. Documented existing utility room configuration including water heater, plumbing infrastructure, and electrical panel specifications to determine compatibility requirements for new AC installation.
Performed comprehensive maintenance and repair on residential HVAC system. Removed and disassembled blower wheel assembly, thoroughly cleaned to remove accumulated dirt and debris, and reinstalled for optimal airflow. Replaced failed run capacitor to restore proper compressor and fan motor operation. Conducted complete coil cleaning of both evaporator and condenser coils, removing significant buildup of dirt, dust, and organic material that was restricting heat transfer efficiency. System tested and verified operational following repairs.