P.K. Wadsworth Heating & Cooling has kept Shaker Heights homeowners comfortable since 1936. We’re experts in climate control who have consistently earned the loyalty and trust of customers by exceeding expectations with best-in-class technicians, reliable service, and custom solutions.
Whether it’s through our preventative maintenance plans, installation of heating and cooling systems, or efficient and effective HVAC repair throughout Shaker Heights, our flexibility, professionalism, industry knowledge, and friendly staff have made all the difference for more than 80 years.
Contact our local HVAC company for repair, replacement, and maintenance services in the Shaker Heights, Ohio area.
Heating Services In Shaker Heights

P.K. Wadsworth is the leading HVAC company in Cleveland, providing heating services in Shaker Heights. From heating system repair to replacement, we’ll perform necessary tasks to keep your system in prime condition while providing you the peace of mind that your home heating is as reliable, safe and efficient as possible. P.K. Wadsworth offers the following heating services:
- Furnace installation
- Furnace replacement
- Furnace maintenance
- Furnace repair
- Boiler installation
- Boiler replacement
- Boiler maintenance
- Boiler repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
Contact us to schedule top-rated heating services, such as furnace repair, heating replacement, and heating installation in Shaker Heights!
Air Conditioning Services In Shaker Heights
With P.K. Wadsworth, an HVAC technician will assess your Shaker Heights home, budget, and comfort preferences. In order to keep you and your family comfortable—even when the temperatures are reaching record highs—we offer the following air conditioner services in Shaker Heights:
- Air conditioner installation
- Air conditioner replacement
- Air conditioner maintenance
- Air conditioner repair
- Ductless system installation
- Ductless system replacement
- Ductless system maintenance
- Ductless system repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
- Contact our local HVAC company to schedule air conditioner services, such as AC repair, replacement, and maintenance in Shaker Heights!
Indoor Air Quality In Shaker Heights, Ohio

Many people are surprised to learn that indoor air can be many times more polluted than outdoor air. That’s because most buildings today are sealed tight to keep heated and cooled air from leaking out. Although this conserves energy, it can create indoor air that’s infested with invisible pollutants that adversely affect health and well-being. Keep the air quality in your Shaker Heights home as clean as possible with our top-rated indoor air quality services.
When you need indoor air quality services in Shaker Heights, there’s only one name you need to know—P.K. Wadsworth.
Choose P.K. Wadsworth As Your Shaker Heights HVAC Company
P.K. Wadsworth has one of the most experienced HVAC companies in Shaker Heights, Ohio. All of our heating and cooling professionals are trained and certified to work on most heating and air conditioning systems, regardless of the brand. From heating replacement to AC repair in Shaker Heights, you can trust our team to get the job done right.
Contact our local HVAC company to schedule heating or air conditioning services throughout Shaker Heights—including AC or furnace repair, HVAC replacement, and HVAC maintenance.
P.K. Wadsworth Heating, Cooling, Plumbing and Electric has completed 20 jobs in Shaker Heights, OH in July 2026. The most recent job was on July 10, 2026.Recent Jobs and Reviews in Shaker Heights, OH
Shaker Heights, OH at a glance
Job Locations and Reviews
Responded to callback for standing water in A/C condensate drain line. Upon arrival, found approximately one inch of water remaining in drain pan from previous day's service visit. Cleared blockage from condensate line, verified proper drainage flow, and confirmed drain pan was emptying completely. System tested and operating within normal parameters with no further drainage issues observed.
# HVAC Cooling Maintenance Completed
Performed comprehensive preventive maintenance on residential split-system air conditioning equipment as part of ongoing seasonal service program. Inspected vertical air handler unit with condensate management system, verified proper operation of electronic monitoring components indicated by active status lights, and confirmed secure mounting and connections. Examined outdoor condensing unit installation, verified all safety labels and manufacturer specifications were intact and legible, and inspected refrigerant line connections and electrical terminations. Confirmed condensate drain lines were clear and functioning properly, checked PVC piping and shutoff valve operation, and verified flexible ductwork connections were sealed and secure. All system components operating within normal parameters with no deficiencies noted at time of service.
Conducted comprehensive evaluation of existing HVAC system and provided full system replacement options to customer. Reviewed previous repair estimate and assessed current equipment condition. Documented existing ductwork configuration and measured installation areas to prepare accurate replacement proposals for both air conditioning unit and complete heating and cooling system upgrades.
Completed routine cooling system maintenance on outdoor condenser unit as part of recurring preventive maintenance program. Inspected condenser coils, protective grille, and external components, confirming all elements in good operational condition with no visible damage or debris obstruction. Documented equipment condition with photographic records showing clean, properly functioning cooling fins and intact protective housing.
Responded to no cooling call affecting entire residence. Upon arrival, inspected Lennox furnace and air conditioning system located in basement mechanical room. Verified thermostat operation showing 72°F set point with system calling for cooling. Checked air filter condition and found filter accessible for inspection. System components including furnace, air handler, and associated PVC condensate drainage piping visually assessed for proper installation and connections. Thermostat displaying proper communication with HVAC equipment and responding to temperature adjustments in cooling mode.
Performed diagnostic evaluation of existing Goodman furnace system and electrical service panel to provide replacement options. Inspected current HVAC equipment including furnace unit, PVC condensate drainage, ductwork configuration, and associated copper refrigerant lines. Evaluated electrical panel capacity and circuit breaker availability to determine compatibility with potential replacement equipment. Documented existing system specifications and installation conditions. Photographed equipment for replacement estimate preparation.
Performed comprehensive cooling system maintenance on residential HVAC unit. Accessed outdoor condensing unit and conducted thorough inspection of all electrical components including capacitor, contactor, and CoreSense diagnostic system. Verified proper wire connections across all terminals and confirmed operational status of all safety controls. Measured and documented system parameters using calibration-grade digital instrumentation, recording temperature differentials and verifying equipment performance within manufacturer specifications. All components found to be functioning properly with no immediate repairs required.
Performed thorough coil cleaning on outdoor condensing unit that exhibited heavy accumulation of dirt, debris, and organic matter on exterior mesh screening and condenser fins. The unit's heat exchange surfaces were heavily contaminated with dark buildup that significantly restricted airflow and reduced system efficiency. Cleaned and restored condenser coils to proper operating condition, removing years of accumulated outdoor contaminants to restore optimal heat transfer capability and system performance.
Responded to service call for non-operational air conditioning unit. Upon inspection, found rooftop commercial HVAC condenser with significant rust corrosion on mounting platform and electrical component housings, along with heavily weathered fan assembly showing oxidation on protective grille and central hub. Assessed electrical disconnects including Mars, DiversiTech, and Siemens components for proper operation and connections, verified condenser fan motor functionality, and restored unit to operational status.
Completed routine preventative maintenance on aging cooling system. Performed comprehensive electrical diagnostics using digital multimeter to verify capacitor functionality and measure voltage readings across system components. Recorded temperature measurements at unit to assess operational performance and confirm proper cooling output within acceptable parameters.
Completed scheduled preventative maintenance on Carrier Infinity cooling system as part of ongoing service plan. Performed comprehensive inspection of air handler unit, verified proper operation of all components, and documented equipment condition with photographic records. Noted moisture accumulation on utility room floor near equipment location and addressed drainage concerns to prevent future issues.
Performed comprehensive cleaning service on outdoor condensing unit that showed significant dirt and debris accumulation at base and throughout system. Removed and thoroughly cleaned blower wheel, performed detailed coil cleaning to restore heat transfer efficiency, and serviced feed tube. Unit exhibited heavy environmental contamination including sediment buildup, indicating extended exposure to outdoor elements. All components cleaned and restored to proper operating condition.
Completed comprehensive cooling season tune-up on residential HVAC system, including inspection of outdoor condenser unit and indoor air handler. Verified proper operation of all components, checked refrigerant levels, cleaned condenser coils, and installed new 12x25x1 Filtrete air filter to ensure optimal airflow and system efficiency for the cooling season.
Completed warranty service for HVAC installation by sealing ductwork in attic space. Inspected and sealed all connections on rectangular metal supply plenum and flexible duct runs to ensure proper system performance and energy efficiency. All ductwork connections were secured and sealed per manufacturer specifications to prevent air leakage and maintain system integrity.
Completed installation of multi-zone ductless mini-split system with five indoor air handler units throughout the residence. Installation coordinated with electrical contractor for proper power supply and circuit requirements. Mounted wall-mounted indoor unit in bedroom above window, installed refrigerant line sets, established proper condensate drainage, and commissioned system with successful operational testing verified by control panel indicators showing power, lock, and WiFi connectivity status.
Responded to complaint of AC unit running excessively while maintaining adequate cooling. Performed diagnostic evaluation using digital manifold gauges to measure system pressures and temperatures. High-side pressure reading showed 159 psig with 37°F superheat and 83% saturation on suction side; low-side registered 66 psig with subcooling readings captured. System operating within acceptable parameters with no refrigerant leaks detected or mechanical failures identified. Unit maintaining proper cooling capacity despite extended run times, which may be attributed to seasonal load demands or thermostat settings rather than equipment malfunction.
Returned to residential property to complete repair of outdoor condensing unit. Successfully replaced failed condenser fan motor, contactor, and capacitor. Performed thorough coil cleaning to restore system efficiency and proper operation. Unit tested and confirmed operating within manufacturer specifications upon completion.
Responded to no cooling call where system would not turn on. Upon arrival, inspected Halcyon inverter air handler unit located in attic space. Found significant condensation accumulation on supply ductwork and verified unit operational status. Documented equipment condition with photos showing moisture on insulated ductwork and air handler installation.
Completed comprehensive cooling season tune-up on five HVAC units. Performed diagnostic testing using calibrated instruments to measure system performance parameters, including temperature differentials and electrical readings across all units. All systems evaluated and found operating within manufacturer specifications.
Completed preventive maintenance inspection on residential HVAC cooling system. Performed comprehensive evaluation of furnace unit, ductwork connections, and air distribution components in basement mechanical room and attic space. Verified proper operation of all system components, inspected flexible and rigid ductwork for secure connections and adequate sealing, and confirmed accessibility for future service needs.