P.K. Wadsworth Heating & Cooling has kept Shaker Heights homeowners comfortable since 1936. We’re experts in climate control who have consistently earned the loyalty and trust of customers by exceeding expectations with best-in-class technicians, reliable service, and custom solutions.
Whether it’s through our preventative maintenance plans, installation of heating and cooling systems, or efficient and effective HVAC repair throughout Shaker Heights, our flexibility, professionalism, industry knowledge, and friendly staff have made all the difference for more than 80 years.
Contact our local HVAC company for repair, replacement, and maintenance services in the Shaker Heights, Ohio area.
Heating Services In Shaker Heights

P.K. Wadsworth is the leading HVAC company in Cleveland, providing heating services in Shaker Heights. From heating system repair to replacement, we’ll perform necessary tasks to keep your system in prime condition while providing you the peace of mind that your home heating is as reliable, safe and efficient as possible. P.K. Wadsworth offers the following heating services:
- Furnace installation
- Furnace replacement
- Furnace maintenance
- Furnace repair
- Boiler installation
- Boiler replacement
- Boiler maintenance
- Boiler repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
Contact us to schedule top-rated heating services, such as furnace repair, heating replacement, and heating installation in Shaker Heights!
Air Conditioning Services In Shaker Heights
With P.K. Wadsworth, an HVAC technician will assess your Shaker Heights home, budget, and comfort preferences. In order to keep you and your family comfortable—even when the temperatures are reaching record highs—we offer the following air conditioner services in Shaker Heights:
- Air conditioner installation
- Air conditioner replacement
- Air conditioner maintenance
- Air conditioner repair
- Ductless system installation
- Ductless system replacement
- Ductless system maintenance
- Ductless system repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
- Contact our local HVAC company to schedule air conditioner services, such as AC repair, replacement, and maintenance in Shaker Heights!
Indoor Air Quality In Shaker Heights, Ohio

Many people are surprised to learn that indoor air can be many times more polluted than outdoor air. That’s because most buildings today are sealed tight to keep heated and cooled air from leaking out. Although this conserves energy, it can create indoor air that’s infested with invisible pollutants that adversely affect health and well-being. Keep the air quality in your Shaker Heights home as clean as possible with our top-rated indoor air quality services.
When you need indoor air quality services in Shaker Heights, there’s only one name you need to know—P.K. Wadsworth.
Choose P.K. Wadsworth As Your Shaker Heights HVAC Company
P.K. Wadsworth has one of the most experienced HVAC companies in Shaker Heights, Ohio. All of our heating and cooling professionals are trained and certified to work on most heating and air conditioning systems, regardless of the brand. From heating replacement to AC repair in Shaker Heights, you can trust our team to get the job done right.
Contact our local HVAC company to schedule heating or air conditioning services throughout Shaker Heights—including AC or furnace repair, HVAC replacement, and HVAC maintenance.
P.K. Wadsworth Heating, Cooling, Plumbing and Electric has completed 20 jobs in Shaker Heights, OH in June 2026. The most recent job was on June 24, 2026.Recent Jobs and Reviews in Shaker Heights, OH
Shaker Heights, OH at a glance
Job Locations and Reviews
Performed routine cooling maintenance on outdoor condensing unit. Inspected condenser coil and found significant accumulation of dust, lint, and debris blocking airflow through the fins and ventilation grilles. Cleaned condenser coil and exterior surfaces to restore proper airflow and system efficiency.
Connected water supply line to humidifier unit on HVAC system. Verified proper installation of humidifier plumbing connections and confirmed system integration with existing gas furnace components.
Completed scheduled cooling system maintenance on residential HVAC unit. Performed comprehensive system diagnostics using digital multimeter to verify electrical performance, measuring voltage and amperage readings on compressor and blower motor circuits. All electrical components tested within manufacturer specifications, with readings indicating proper system operation at 40.5 amps and appropriate voltage levels. Inspected condenser coil, evaporator components, and all electrical connections including capacitor and control board functionality. Applied appropriate maintenance lubrication to moving components as needed. Provided customer with replacement air filter as requested per maintenance agreement requirements.
Leveled outdoor condensing unit that had settled unevenly on concrete pad. Used precision level to verify proper positioning and adjusted unit to ensure optimal performance and prevent potential compressor damage from improper orientation. Unit now sits level on pad with correct drainage pitch maintained.
Completed scheduled cooling system maintenance as part of ongoing preventive maintenance program. Performed comprehensive inspection of air handler unit, including blower motor assembly, heat exchanger, and refrigerant lines. Documented significant rust and corrosion present on heat exchanger tubes and copper components, indicating advanced oxidation and equipment age. Verified blower motor operation and electrical connections. Inspected copper refrigerant piping and brass fittings for integrity. System operational at time of service completion, though heat exchanger corrosion noted for future monitoring and potential replacement consideration.
Completed preventive maintenance service on two residential cooling systems. Performed comprehensive inspection of outdoor condenser units, including visual assessment of coil condition, electrical connections, and proper mounting. Verified operational status of both systems and checked refrigerant levels. Replaced dirty air filter with new filter to restore proper airflow and system efficiency. All equipment found to be in good working order with no immediate service needs identified.
Completed comprehensive cooling maintenance on aging HVAC system in basement mechanical room. Performed standard preventive maintenance procedures including electrical current measurements using clamp meter, inspected furnace unit with connected Aprilaire humidifier, verified proper operation of PVC condensate drain lines, and examined copper refrigerant lines and ductwork components. All equipment found operational with routine maintenance tasks completed per manufacturer specifications for systems over 10 years old.
Completed scheduled preventive maintenance on residential split cooling system including indoor furnace unit and outdoor condensing unit. Performed comprehensive inspection of both components, verified proper refrigerant levels, checked electrical connections, cleaned condenser coils, tested system operation and airflow, and confirmed all safety controls functioning within manufacturer specifications. System operating efficiently with no deficiencies noted.
Completed scheduled plumbing maintenance visit for residential water heater system. Performed routine inspection of water heater unit, expansion tank, and associated plumbing connections including copper supply lines and PVC discharge piping. Verified proper operation of system components, checked for leaks or signs of deterioration, and documented current condition of equipment with photographic records. All components found to be functioning within normal parameters.
Returned to site to replace defective WiFi control board on HVAC blower assembly under warranty. Accessed unit in attic space, disconnected existing wiring harness from blower motor assembly, and removed failed WiFi board. Installed new WiFi board, reconnected all electrical connections including multi-speed motor wiring, and verified proper operation of blower motor and wireless connectivity. Unit tested and operating normally.
Completed full HVAC system replacement including installation of new air handling unit suspended from ceiling joists with chain mounting hardware in mechanical space. Connected flexible aluminum ductwork with secure fastening straps and installed wall-mounted equipment cabinet. Installed new ceiling-mounted sensor or detector device in finished living space to integrate with replacement system.
Responded to E2 error code indicating high refrigerant pressure or blockage on HVAC air handler unit. Upon inspection, verified filter condition was satisfactory despite system alert. Diagnosed system malfunction, performed necessary troubleshooting procedures, and cleared error condition to restore normal operation.
Completed scheduled HVAC cooling maintenance inspection and system evaluation. Performed temperature diagnostics using infrared thermometer, recording ambient readings of 68.5°F. Inspected electrical connections, terminals, and wiring at the air handler unit, verifying proper grounding conductor installation and secure terminal connections at the junction box. All electrical components, including motor assembly and associated wiring, were found to be in proper working condition with no immediate concerns noted.
Completed scheduled preventive maintenance on split-system air conditioning unit. Performed comprehensive inspection of wall-mounted indoor evaporator unit and outdoor condensing unit, measuring operating temperature at 24.1°F at the indoor unit using calibrated digital instrumentation. Verified proper refrigerant line insulation integrity, confirmed secure mounting of outdoor condenser on elevated deck brackets, and ensured all system components were operating within manufacturer specifications for optimal cooling performance.
Responded to customer concern regarding wall damage potentially related to AC system. Performed visual inspection of ceiling-mounted HVAC installation including air handler unit, ductwork, and refrigerant line insulation. Documented existing conditions of reflective duct insulation, foam-wrapped refrigerant lines, and connections between air handling unit and distribution ductwork. All components appear to be in normal working condition with no visible signs of active leaks or condensation issues that would cause wall moisture damage.
Completed comprehensive cooling system maintenance on HVAC unit. Performed thorough inspection of blower motor assembly, verifying proper wire connections and motor operation. Inspected blower wheel for debris and confirmed unrestricted airflow. Evaluated air filtration system and ensured adequate filter supply is available for ongoing maintenance. All components operating within normal parameters with no deficiencies noted.
Completed scheduled preventive maintenance on two residential cooling systems. Performed comprehensive inspection of both HVAC units including air handler and furnace components. Checked refrigerant lines, verified proper drainage through condensate system, and inspected all PVC piping connections for leaks. Cleaned accessible components, verified electrical connections, and ensured proper airflow through the systems. Both units operating within normal parameters upon completion of maintenance service.
Completed comprehensive cooling system maintenance inspection on HVAC unit. Performed electrical diagnostics using Klein Tools testing instrument to verify proper voltage and amperage levels throughout the system. All electrical components tested within normal operating parameters, and exterior condenser unit inspected with no issues identified.
Completed routine cooling maintenance on rooftop HVAC unit. Inspected electrical connections at control panel, verified all terminal connections were secure, and checked wiring integrity across multiple circuits. All electrical components showed normal wear consistent with outdoor installation, with connections functioning properly and no immediate safety concerns identified.
Completed scheduled maintenance on UNICO cooling system. Performed comprehensive inspection of electrical components, including capacitor and fuse assembly. Verified proper wire connections, tested system operation, and confirmed all components functioning within manufacturer specifications.