P.K. Wadsworth Heating & Cooling has kept Shaker Heights homeowners comfortable since 1936. We’re experts in climate control who have consistently earned the loyalty and trust of customers by exceeding expectations with best-in-class technicians, reliable service, and custom solutions.
Whether it’s through our preventative maintenance plans, installation of heating and cooling systems, or efficient and effective HVAC repair throughout Shaker Heights, our flexibility, professionalism, industry knowledge, and friendly staff have made all the difference for more than 80 years.
Contact our local HVAC company for repair, replacement, and maintenance services in the Shaker Heights, Ohio area.
Heating Services In Shaker Heights

P.K. Wadsworth is the leading HVAC company in Cleveland, providing heating services in Shaker Heights. From heating system repair to replacement, we’ll perform necessary tasks to keep your system in prime condition while providing you the peace of mind that your home heating is as reliable, safe and efficient as possible. P.K. Wadsworth offers the following heating services:
- Furnace installation
- Furnace replacement
- Furnace maintenance
- Furnace repair
- Boiler installation
- Boiler replacement
- Boiler maintenance
- Boiler repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
Contact us to schedule top-rated heating services, such as furnace repair, heating replacement, and heating installation in Shaker Heights!
Air Conditioning Services In Shaker Heights
With P.K. Wadsworth, an HVAC technician will assess your Shaker Heights home, budget, and comfort preferences. In order to keep you and your family comfortable—even when the temperatures are reaching record highs—we offer the following air conditioner services in Shaker Heights:
- Air conditioner installation
- Air conditioner replacement
- Air conditioner maintenance
- Air conditioner repair
- Ductless system installation
- Ductless system replacement
- Ductless system maintenance
- Ductless system repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
- Contact our local HVAC company to schedule air conditioner services, such as AC repair, replacement, and maintenance in Shaker Heights!
Indoor Air Quality In Shaker Heights, Ohio

Many people are surprised to learn that indoor air can be many times more polluted than outdoor air. That’s because most buildings today are sealed tight to keep heated and cooled air from leaking out. Although this conserves energy, it can create indoor air that’s infested with invisible pollutants that adversely affect health and well-being. Keep the air quality in your Shaker Heights home as clean as possible with our top-rated indoor air quality services.
When you need indoor air quality services in Shaker Heights, there’s only one name you need to know—P.K. Wadsworth.
Choose P.K. Wadsworth As Your Shaker Heights HVAC Company
P.K. Wadsworth has one of the most experienced HVAC companies in Shaker Heights, Ohio. All of our heating and cooling professionals are trained and certified to work on most heating and air conditioning systems, regardless of the brand. From heating replacement to AC repair in Shaker Heights, you can trust our team to get the job done right.
Contact our local HVAC company to schedule heating or air conditioning services throughout Shaker Heights—including AC or furnace repair, HVAC replacement, and HVAC maintenance.
P.K. Wadsworth Heating, Cooling, Plumbing and Electric has completed 20 jobs in Shaker Heights, OH in June 2026. The most recent job was on June 30, 2026.Recent Jobs and Reviews in Shaker Heights, OH
Shaker Heights, OH at a glance
Job Locations and Reviews
Completed scheduled cooling maintenance on Unico high-velocity HVAC system. Performed comprehensive inspection of blower module, verified proper operation of 1/2 HP motor, checked electrical connections at 120/208-230V specifications, inspected refrigerant lines and insulation integrity, and confirmed all safety labels and manufacturer specifications were clearly visible and equipment was operating within normal parameters.
Responded to service call and accessed property through side door as arranged. Removed heavily soiled pleated air filter from HVAC system showing significant dust and debris accumulation. Installed new replacement filter to restore proper airflow and system efficiency. System operational upon completion.
Completed scheduled preventive maintenance on residential cooling system. Performed electrical diagnostics using clamp meter to verify compressor amperage draw at 16.12 amps, confirming unit operation within manufacturer specifications. Inspected condenser unit exterior components including protective fan grille and housing for proper condition and airflow clearance.
Completed a 100-amp main electrical panel replacement and installed a whole home surge protection system. Removed existing panel, installed new breaker box with updated circuit breakers, properly terminated and organized all branch circuit wiring, and integrated surge protective device to safeguard all electrical equipment throughout the residence.
Completed routine cooling maintenance on Central Cooling Inc. CAPF4860C6DB air conditioning unit. Replaced air filter as needed, verified system operation with supply air temperature reading of 45.1°F, and confirmed all specifications and refrigerant information on unit nameplate for proper documentation.
Performed comprehensive cooling system tune-up on attic-mounted green air handling unit. Accessed equipment via side door entry per customer instructions. Completed full preventive maintenance inspection including filter check, coil inspection, electrical connections verification, and refrigerant level assessment. Replaced thermostat batteries to resolve low-battery warning message displayed on control panel. Verified proper airflow through flexible ductwork system and confirmed adequate insulation integrity throughout attic installation. Tested system operation and confirmed unit cycling properly with no abnormal conditions detected. All components functioning within normal parameters upon completion.
Completed seasonal cooling maintenance on dual HVAC systems as part of ongoing preventative maintenance program. Performed comprehensive inspection and servicing of Bryant furnace with integrated cooling system, including air handler components, ductwork, and associated humidification equipment. Verified proper operation of all mechanical and electrical components, checked refrigerant levels, cleaned condensate drainage systems, and confirmed optimal airflow throughout both systems to ensure efficient cooling performance for the upcoming season.
Completed comprehensive cooling system tune-up including performance diagnostics and electrical testing. Verified system operation with temperature differential readings at 93°F and conducted amperage measurements on outdoor condensing unit to ensure proper compressor function and electrical draw within manufacturer specifications.
Completed scheduled cooling maintenance on a dual-zone HVAC system, servicing both the attic-mounted horizontal air handler unit and the exterior condenser unit. Performed comprehensive inspection of all components including refrigerant lines, electrical connections, ductwork, condensate drainage systems, and verified proper operation of both units with no deficiencies noted.
Performed scheduled cooling system maintenance on Goodman HVAC unit. Inspected furnace cabinet, ductwork, and condensate drain system; replaced air filter; verified proper operation of all cooling components. System operating within normal parameters with no issues identified.
Completed installation of Unico high-velocity air conditioning system with addition of three new supply runs to expand coverage area. Installed exterior disconnect box with proper conduit routing on brick exterior wall for air handler unit. Performed system startup and commissioning, verifying refrigerant charge using digital manifold gauges with R32 refrigerant readings showing 100.7 psi low side, 262.7 psi high side, superheat at 26.3°F, and subcooling at 8.6°F within manufacturer specifications. All electrical connections secured, system tested and operational.
Conducted comprehensive electrical assessment for electric vehicle charging station installation in residential garage. Evaluated existing electrical panel capacity, circuit availability, and optimal mounting location for Level 2 EV charger. Documented current garage electrical infrastructure, including wire routing pathways from main service panel through basement utility area to proposed charging station location. Photographed existing conditions to support load calculation requirements and permit application process for future installation.
# HVAC Cooling Maintenance Summary
Completed scheduled preventive maintenance service on residential cooling system. Performed system inspection, replaced air filter with new 16x20x1 pleated filter, and verified proper airflow through air handler unit.
---
# Detailed Service Description
Performed comprehensive preventive maintenance service on residential HVAC cooling system as part of ongoing maintenance agreement. Upon arrival, conducted visual inspection of air handler unit and associated components located in mechanical room.
Accessed air handler unit and removed existing 16x20x1 pleated air filter for inspection. Filter showed normal accumulation of dust and debris consistent with operating period since last service. Evaluated filter condition and determined replacement was necessary to maintain optimal system performance and indoor air quality.
Installed new 16x20x1 pleated air filter with proper orientation to ensure correct airflow direction through the system. Verified f
Completed scheduled preventive maintenance on residential HVAC cooling system. Inspected air handler unit in basement utility area, verified proper operation of all components, and confirmed supply air temperature at 48.0°F indicating adequate cooling performance. Checked filter condition, ductwork connections, and overall system integrity with no deficiencies noted.
Completed preventive maintenance inspection on residential cooling system. Performed diagnostic testing using digital instruments, inspected outdoor unit electrical components including capacitor and contactor assembly, verified proper wire connections and control operation. System found operating within normal parameters with all electrical connections secure and components functioning properly.
Completed scheduled cooling maintenance on Carrier HVAC system. Performed comprehensive inspection of furnace unit, verified proper operation of Aprilaire control system displaying 63°F, checked all electrical connections and control wiring, inspected ductwork including metallic flexible ducts and PVC condensate lines for proper installation and condition. All components found operating within normal parameters. System ready for cooling season operation.
Responded to no cooling complaint on residential air conditioning system. Upon arrival, inspected outdoor condensing unit and found failed dual run capacitor preventing compressor and condenser fan motor operation. Removed access panel, tested capacitor with multimeter confirming zero capacitance on both common and fan terminals. Replaced defective capacitor with proper MFD-rated component, verified all electrical connections secure, and restored power to system. Confirmed compressor and condenser fan motor startup, monitored system operation through complete cooling cycle, and verified proper airflow at indoor air handler. System restored to normal cooling operation.
Completed full HVAC system installation including new air handler unit mounted in interior utility closet and AC condenser unit positioned on roof. Installed all necessary ductwork connections, electrical wiring to panel, and refrigerant lines between indoor and outdoor units. System tested and verified operational upon completion.
Completed scheduled preventive maintenance on residential split-system air conditioning unit. Performed comprehensive inspection of outdoor condenser unit and indoor air handler, including cleaning of condenser coils, verification of refrigerant levels and pressures, testing of electrical connections and capacitors, and confirmation of proper system operation. All components found to be functioning within normal parameters with no repairs required at this time.
Performed routine cooling maintenance on outdoor condensing unit. Inspected condenser coil and found significant accumulation of dust, lint, and debris blocking airflow through the fins and ventilation grilles. Cleaned condenser coil and exterior surfaces to restore proper airflow and system efficiency.