P.K. Wadsworth Heating & Cooling has kept Shaker Heights homeowners comfortable since 1936. We’re experts in climate control who have consistently earned the loyalty and trust of customers by exceeding expectations with best-in-class technicians, reliable service, and custom solutions.
Whether it’s through our preventative maintenance plans, installation of heating and cooling systems, or efficient and effective HVAC repair throughout Shaker Heights, our flexibility, professionalism, industry knowledge, and friendly staff have made all the difference for more than 80 years.
Contact our local HVAC company for repair, replacement, and maintenance services in the Shaker Heights, Ohio area.
Heating Services In Shaker Heights

P.K. Wadsworth is the leading HVAC company in Cleveland, providing heating services in Shaker Heights. From heating system repair to replacement, we’ll perform necessary tasks to keep your system in prime condition while providing you the peace of mind that your home heating is as reliable, safe and efficient as possible. P.K. Wadsworth offers the following heating services:
- Furnace installation
- Furnace replacement
- Furnace maintenance
- Furnace repair
- Boiler installation
- Boiler replacement
- Boiler maintenance
- Boiler repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
Contact us to schedule top-rated heating services, such as furnace repair, heating replacement, and heating installation in Shaker Heights!
Air Conditioning Services In Shaker Heights
With P.K. Wadsworth, an HVAC technician will assess your Shaker Heights home, budget, and comfort preferences. In order to keep you and your family comfortable—even when the temperatures are reaching record highs—we offer the following air conditioner services in Shaker Heights:
- Air conditioner installation
- Air conditioner replacement
- Air conditioner maintenance
- Air conditioner repair
- Ductless system installation
- Ductless system replacement
- Ductless system maintenance
- Ductless system repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
- Contact our local HVAC company to schedule air conditioner services, such as AC repair, replacement, and maintenance in Shaker Heights!
Indoor Air Quality In Shaker Heights, Ohio

Many people are surprised to learn that indoor air can be many times more polluted than outdoor air. That’s because most buildings today are sealed tight to keep heated and cooled air from leaking out. Although this conserves energy, it can create indoor air that’s infested with invisible pollutants that adversely affect health and well-being. Keep the air quality in your Shaker Heights home as clean as possible with our top-rated indoor air quality services.
When you need indoor air quality services in Shaker Heights, there’s only one name you need to know—P.K. Wadsworth.
Choose P.K. Wadsworth As Your Shaker Heights HVAC Company
P.K. Wadsworth has one of the most experienced HVAC companies in Shaker Heights, Ohio. All of our heating and cooling professionals are trained and certified to work on most heating and air conditioning systems, regardless of the brand. From heating replacement to AC repair in Shaker Heights, you can trust our team to get the job done right.
Contact our local HVAC company to schedule heating or air conditioning services throughout Shaker Heights—including AC or furnace repair, HVAC replacement, and HVAC maintenance.
P.K. Wadsworth Heating, Cooling, Plumbing and Electric has completed 20 jobs in Shaker Heights, OH in June 2026. The most recent job was on June 5, 2026.Recent Jobs and Reviews in Shaker Heights, OH
Shaker Heights, OH at a glance
Job Locations and Reviews
Responded to no cooling complaint for commercial office mini split system. Upon inspection, discovered severe electrical failure in the indoor unit's junction box with evidence of arcing, overheating, and burnt wiring at the terminal connections. Found charred insulation and melted debris throughout the electrical compartment, indicating a significant electrical fault had occurred. Assessed the damage to terminal blocks labeled S1, S2, S3, L1, and L2, along with compromised wire connections. Documented the electrical damage and verified the system was inoperable due to the failure. Collected service fee and provided photographic documentation of the electrical fault for repair estimate purposes.
Conducted comprehensive electrical inspection of residential property. Inspected exterior Tesla wall-mounted electrical equipment installation at foundation level near glass block window, verifying proper placement and connection integrity. Performed interior evaluation of fluorescent lighting fixture, examining ballast operation, wiring connections, and tube functionality across three-lamp configuration.
Responded to no cooling call on system less than 10 years old. Upon arrival, verified thermostat was calling for cooling but outdoor unit was not energizing. Checked thermostat settings and confirmed proper operation and communication with HVAC system, resolving the no cool condition.
Completed comprehensive cooling maintenance on residential HVAC system, including inspection of outdoor condensing unit with service valves and refrigerant lines, and indoor air handler located in upper level space. All electrical components had been previously serviced; performed mechanical inspection, verified proper refrigerant line connections, checked service valve operation, and confirmed system readiness for cooling season operation.
Completed preventive maintenance on two residential cooling systems. Performed comprehensive inspection of outdoor condensing units, testing electrical components including capacitors and contactors with multimeter to verify proper operation. Inspected indoor air handlers and associated furnace units in basement mechanical room, checking refrigerant line connections, condensate drainage systems, and PVC piping for proper function. All systems tested and operating within normal parameters upon completion of maintenance procedures.
Performed complimentary electrical inspection of residential service panel and utility area receptacles. Inspected main disconnect switch (Square D R343 series), verified proper cable terminations at terminal blocks, and confirmed secure connections of incoming service conductors. Evaluated flexible metal conduit installation and mounting integrity on plywood substrate. Assessed downstream branch circuit protection and examined receptacle installation in utility area including proper grounding and box mounting on masonry wall. All components photographed for documentation purposes. System found to be in serviceable condition with no immediate safety concerns identified during visual inspection.
Completed scheduled preventative maintenance on residential cooling system. Inspected air handler unit and replaced dirty pleated air filter with new filter to ensure proper airflow and system efficiency. All equipment operating within normal parameters upon completion of service.
Completed comprehensive electrical inspection of residential system. Documented main electrical panel configuration showing dual-row circuit breaker arrangement with proper bus bar connections and multiple active circuits serving various building loads. Photographed water heater installation with associated electrical connections and verified proper wiring configuration to mechanical equipment.
Returned to complete repair by installing new hard start capacitor (TURBO 200 X, 7.5mfd 880/994 rating) in the outdoor unit control panel and replaced three air filters in the system. All components tested and operational upon completion.
Completed scheduled preventive maintenance on two cooling systems as part of ongoing service agreement. Inspected attic-installed HVAC components including flexible and rigid ductwork, supply registers, and condensate drain lines. Verified proper insulation wrapping on duct connections and confirmed all PVC drain piping was secure and properly supported. Both systems operational with no deficiencies noted.
Completed scheduled preventive maintenance on residential cooling system as part of ongoing service plan. Performed comprehensive inspection of indoor air handler unit, measuring supply air temperature at ceiling register which indicated proper cooling performance at 51.6°F. Inspected outdoor condensing unit, verifying proper operation, clearance from surrounding vegetation, and adequate drainage on gravel pad. System operating within normal parameters with no deficiencies noted.
Completed comprehensive preventive maintenance service on residential cooling system aged 10+ years. Performed standard inspection of outdoor condensing unit, verified electrical connections at main panel, assessed system components for proper operation, and documented equipment condition through photographic records. Unit accessible despite overgrown landscaping; all maintenance protocols executed per manufacturer specifications with system operating within normal parameters upon completion.
Completed scheduled preventive maintenance on residential cooling system. Inspected electrical contactor assembly, noting oxidation and wear on contact points consistent with normal operation. Verified all wire connections secure at terminals with proper phase wiring intact. Examined air return ventilation grille, confirming adequate airflow and proper slat alignment. System operational and functioning within normal parameters upon completion of maintenance visit.
Replaced failed condenser fan motor and dual-run capacitor on outdoor HVAC unit. Removed access panel to diagnose system malfunction, disconnected faulty motor and capacitor assembly, and installed new components with proper electrical connections. Verified all wire terminations were secure, tested capacitor ratings matched system specifications, and confirmed proper operation of condensing unit before restoring power and closing access panel.
Completed scheduled cooling season maintenance on two UNICO high-velocity air conditioning systems. Performed comprehensive inspection of Frigidaire air handler unit, verified proper airflow through flexible ductwork connections, checked refrigerant levels, and replaced air filter. Both systems tested and confirmed operational for cooling season.
Responded to service call for residential air conditioning system found to be completely flat on refrigerant. Upon inspection, determined that the existing HVAC equipment, including both the indoor air handler and outdoor condensing unit, are original to the home and have reached the end of their serviceable life expectancy. Evaluated the electrical service panel and existing equipment configuration in the basement utility area. Provided comprehensive replacement options to the homeowner, including system sizing recommendations and equipment specifications appropriate for the application. Documented existing conditions with photographs of the current air handler unit showing copper refrigerant lines and the electrical breaker panel with circuit identification. Recommended full system replacement due to age of equipment and loss of refrigerant charge, as repair would not be cost-effective given the overall condition and age of the components.
Performed scheduled maintenance on commercial generator system. Inspected internal components including compressor unit, refrigerant lines, and electrical connections. Verified all warning labels and safety documentation were properly displayed and legible on equipment exterior panel.
Completed preventive maintenance on Unico MVP high-velocity cooling system. Inspected indoor furnace unit and outdoor condensing unit, verified proper operation of all components, checked refrigerant levels, and confirmed system is functioning within manufacturer specifications for the upcoming cooling season.
Responded to service call for boiler sight glass leak. Upon inspection, confirmed active leak at sight glass assembly due to deteriorated O-ring seals. Disassembled sight glass unit, removed failed gaskets, and installed new O-ring seals on both mounting points. Reassembled sight glass assembly, verified proper seating of all components, and pressure-tested system to confirm leak was eliminated and boiler returned to normal operation.
Completed routine cooling maintenance on Daikin outdoor condenser unit. Performed system inspection, cleaned condenser coils, verified proper airflow through louvers, and confirmed all electrical connections and refrigerant lines were secure and operating within normal parameters.