P.K. Wadsworth Heating & Cooling has kept Shaker Heights homeowners comfortable since 1936. We’re experts in climate control who have consistently earned the loyalty and trust of customers by exceeding expectations with best-in-class technicians, reliable service, and custom solutions.
Whether it’s through our preventative maintenance plans, installation of heating and cooling systems, or efficient and effective HVAC repair throughout Shaker Heights, our flexibility, professionalism, industry knowledge, and friendly staff have made all the difference for more than 80 years.
Contact our local HVAC company for repair, replacement, and maintenance services in the Shaker Heights, Ohio area.
Heating Services In Shaker Heights

P.K. Wadsworth is the leading HVAC company in Cleveland, providing heating services in Shaker Heights. From heating system repair to replacement, we’ll perform necessary tasks to keep your system in prime condition while providing you the peace of mind that your home heating is as reliable, safe and efficient as possible. P.K. Wadsworth offers the following heating services:
- Furnace installation
- Furnace replacement
- Furnace maintenance
- Furnace repair
- Boiler installation
- Boiler replacement
- Boiler maintenance
- Boiler repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
Contact us to schedule top-rated heating services, such as furnace repair, heating replacement, and heating installation in Shaker Heights!
Air Conditioning Services In Shaker Heights
With P.K. Wadsworth, an HVAC technician will assess your Shaker Heights home, budget, and comfort preferences. In order to keep you and your family comfortable—even when the temperatures are reaching record highs—we offer the following air conditioner services in Shaker Heights:
- Air conditioner installation
- Air conditioner replacement
- Air conditioner maintenance
- Air conditioner repair
- Ductless system installation
- Ductless system replacement
- Ductless system maintenance
- Ductless system repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
- Contact our local HVAC company to schedule air conditioner services, such as AC repair, replacement, and maintenance in Shaker Heights!
Indoor Air Quality In Shaker Heights, Ohio

Many people are surprised to learn that indoor air can be many times more polluted than outdoor air. That’s because most buildings today are sealed tight to keep heated and cooled air from leaking out. Although this conserves energy, it can create indoor air that’s infested with invisible pollutants that adversely affect health and well-being. Keep the air quality in your Shaker Heights home as clean as possible with our top-rated indoor air quality services.
When you need indoor air quality services in Shaker Heights, there’s only one name you need to know—P.K. Wadsworth.
Choose P.K. Wadsworth As Your Shaker Heights HVAC Company
P.K. Wadsworth has one of the most experienced HVAC companies in Shaker Heights, Ohio. All of our heating and cooling professionals are trained and certified to work on most heating and air conditioning systems, regardless of the brand. From heating replacement to AC repair in Shaker Heights, you can trust our team to get the job done right.
Contact our local HVAC company to schedule heating or air conditioning services throughout Shaker Heights—including AC or furnace repair, HVAC replacement, and HVAC maintenance.
P.K. Wadsworth Heating, Cooling, Plumbing and Electric has completed 20 jobs in Shaker Heights, OH between May 2026 and June 2026. The most recent job was on June 3, 2026.Recent Jobs and Reviews in Shaker Heights, OH
Shaker Heights, OH at a glance
Job Locations and Reviews
Completed preventive maintenance on two residential cooling systems. Inspected blower motor assembly, verified electrical connections, and assessed airflow components. Applied coil cleaner to evaporator coils and checked all mechanical components for proper operation. Both systems tested and confirmed operational with no issues identified.
Conducted on-site evaluation for air conditioning system installation as an add-on to existing HVAC setup in residential basement utility area. Assessed electrical infrastructure including current panel configuration and conduit routing to determine compatibility and capacity for new AC unit integration with existing green-cabinet furnace and ductwork system, with proposal to bundle electrical panel upgrade work alongside air conditioning installation pending customer approval.
Completed comprehensive cooling maintenance on residential HVAC system, including thorough blower wheel cleaning to restore optimal airflow and system efficiency. Performed electrical diagnostics using digital multimeter to verify proper system operation and component functionality. System tested and confirmed operating within manufacturer specifications following maintenance completion.
Responded to service call for air conditioning system not cooling properly with suspected refrigerant leak. Performed comprehensive system inspection including examination of indoor evaporator coil assembly, refrigerant line insulation, and outdoor condenser unit. Documented equipment condition with photographs showing interior mechanical components, blower assembly, refrigerant lines, and outdoor unit location. Provided second opinion assessment as requested regarding system performance and potential coolant leak diagnosis.
Responded to callback regarding inadequate cooling on upstairs unit following previous maintenance visit. Upon arrival, evaluated system performance and airflow concerns reported after refrigerant was added during prior service. Conducted thorough inspection of indoor and outdoor components to diagnose cooling deficiency. Verified thermostat operation and temperature differential across evaporator coil. Assessed refrigerant charge levels and system pressures to ensure proper operation. Identified and corrected issues affecting cooling performance to restore adequate airflow and temperature output.
Completed scheduled preventive maintenance on outdoor air conditioning condenser unit. Performed comprehensive system inspection with access panel removed to evaluate electrical components, wiring connections, capacitor condition, and contactor operation. All components found in satisfactory working condition with proper wire terminations secured and organized for optimal performance throughout the cooling season.
Completed routine cooling system maintenance on residential air conditioning unit. Performed comprehensive inspection of outdoor condensing unit, including examination of condenser coils, fan assembly, and electrical components. Accessed control panel to verify proper operation of circuit board, capacitor, and associated wiring connections. Removed debris and fallen leaves from around unit exterior to ensure adequate airflow and system efficiency.
Completed electrical panel assessment for customer considering air conditioning installation. Evaluated existing main panel and sub-panel configuration, documented current breaker layout and capacity, photographed electrical infrastructure including bus bar connections and circuit distribution. Assessed available amperage and determined panel replacement requirements to support additional AC load demands. Provided detailed estimate for panel upgrade to accommodate future HVAC system integration.
Replaced failed condenser fan motor and capacitor on outdoor AC unit. Performed thorough cleaning of condenser coils and unit exterior, removing significant accumulation of dirt, leaves, and organic debris. Installed hard start kit to improve compressor performance and longevity.
Conducted HVAC equipment assessment for system replacement at condo unit with easy accessibility. Evaluated existing thermostat wiring configuration with properly connected Y, C, W, G, R, and OB terminals, and inspected outdoor condenser unit positioned on concrete pad with decorative rock surround against brick wall exterior. Documented current equipment conditions and provided replacement options for complete system upgrade.
# HVAC Cooling Maintenance - Two Systems
Completed comprehensive cooling maintenance on two HVAC systems as part of ongoing preventive maintenance program. Performed electrical diagnostics using digital multimeter to verify proper voltage and amperage readings at outdoor unit control panel. Measured operational parameters showing 0.713V and 0.008V readings during system testing. Inspected control board circuitry, including CEBD43|283-03_B interface board with multiple capacitors, terminal connections, and wire harnesses. Verified all electrical connections at terminal blocks with proper color-coded wiring (red, green, black, white, yellow, and brown/orange conductors). Confirmed control board functionality and secure mounting on equipment housing. Both systems operating within normal parameters upon completion of maintenance procedures.
Responded to no cooling complaint and diagnosed condenser fan motor failure. Found fan motor drawing 2 amps against a rated maximum of 1.1 amps, causing system to trip on overload protection. Observed fan operating at approximately one-third normal speed before stopping completely. Verified 27VAC present at unit but contactor not receiving proper voltage due to safety lockout from overamping condition. Turned disconnect off to prevent further system damage and documented findings with photos of electrical components and internal unit condition.
Conducted comprehensive HVAC system replacement estimate for residential property, evaluating existing basement installation including electrical service panel, gas lines, and ductwork infrastructure. Presented three tiered replacement options for complete A/C and gas furnace systems: Good tier featuring up to 13.4 SEER cooling and 80% AFUE heating efficiency, Better tier with up to 14 SEER and 96% AFUE high-efficiency furnace, and Best tier offering up to 16 SEER and 96% AFUE for optimal performance and energy savings. Documented existing utility room conditions, mechanical space layout, and current infrastructure to determine proper equipment sizing and installation requirements for full system replacement.
Completed scheduled cooling maintenance on two HVAC systems as part of ongoing preventive maintenance program. Performed comprehensive inspection of outdoor condensing units, including examination of protective grills, access panels, and electrical connections. Verified proper wiring connections at contactor terminals, inspected all wire terminations for secure attachment and signs of wear or corrosion. Removed minor debris from unit tops, checked electrical components for proper operation, and confirmed systems are operating within normal parameters for the cooling season.
Completed electrical inspection of rooftop HVAC condensing unit and associated components. Documented electrical connections, capacitor, contactor assembly, and refrigerant line routing. Verified wiring configurations including power supply connections and control circuits. Inspected unit mounting, structural support framework, and surrounding rooftop installation conditions to ensure compliance with electrical safety standards.
Completed preventive maintenance service on two Bryant air conditioning systems as part of scheduled cooling season maintenance. Performed comprehensive inspection of both outdoor condensing units, including examination of electrical components, capacitors, contactors, and refrigerant line connections. Verified proper operation of condenser fan motors, checked electrical connections for tightness and signs of wear, and inspected unit housings for any damage or deterioration. Both systems operating within normal parameters with no deficiencies noted at time of service.
Completed routine cooling season maintenance on residential HVAC system. Performed comprehensive inspection of furnace unit and blower assembly, verified all electrical connections secure, and confirmed proper operation of ventilation components. All equipment found in good working condition with no issues identified.
Completed installation of new air conditioning system in interior closet space. Installed air handler unit above existing furnace, connected PVC condensate drain lines and venting, mounted electrical disconnect box with proper wiring connections, and verified system operation. All equipment installed per manufacturer specifications with appropriate safety labels and clearances maintained.
Performed comprehensive cooling system maintenance on Goodman brand outdoor condensing unit. Inspected condenser coils, fan assembly, and electrical components for proper operation. Unit found to be in functional condition with normal outdoor weathering present on exterior surfaces.
Performed plumbing inspection focusing on expansion tank system that has required multiple replacements in recent years. Examined horizontally-mounted white pressure tank with associated copper piping, PVC connections, brass fittings, and pressure gauge reading near bottom of scale. Documented condition of system components including visible corrosion and green patina on copper pipes, blue-handled valve, flexible corrugated hoses, and what appears to be a filter or pressure regulator in the assembly. Photographed installation for record purposes to track ongoing expansion tank performance issues.