P.K. Wadsworth Heating & Cooling has kept Shaker Heights homeowners comfortable since 1936. We’re experts in climate control who have consistently earned the loyalty and trust of customers by exceeding expectations with best-in-class technicians, reliable service, and custom solutions.
Whether it’s through our preventative maintenance plans, installation of heating and cooling systems, or efficient and effective HVAC repair throughout Shaker Heights, our flexibility, professionalism, industry knowledge, and friendly staff have made all the difference for more than 80 years.
Contact our local HVAC company for repair, replacement, and maintenance services in the Shaker Heights, Ohio area.
Heating Services In Shaker Heights

P.K. Wadsworth is the leading HVAC company in Cleveland, providing heating services in Shaker Heights. From heating system repair to replacement, we’ll perform necessary tasks to keep your system in prime condition while providing you the peace of mind that your home heating is as reliable, safe and efficient as possible. P.K. Wadsworth offers the following heating services:
- Furnace installation
- Furnace replacement
- Furnace maintenance
- Furnace repair
- Boiler installation
- Boiler replacement
- Boiler maintenance
- Boiler repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
Contact us to schedule top-rated heating services, such as furnace repair, heating replacement, and heating installation in Shaker Heights!
Air Conditioning Services In Shaker Heights
With P.K. Wadsworth, an HVAC technician will assess your Shaker Heights home, budget, and comfort preferences. In order to keep you and your family comfortable—even when the temperatures are reaching record highs—we offer the following air conditioner services in Shaker Heights:
- Air conditioner installation
- Air conditioner replacement
- Air conditioner maintenance
- Air conditioner repair
- Ductless system installation
- Ductless system replacement
- Ductless system maintenance
- Ductless system repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
- Contact our local HVAC company to schedule air conditioner services, such as AC repair, replacement, and maintenance in Shaker Heights!
Indoor Air Quality In Shaker Heights, Ohio

Many people are surprised to learn that indoor air can be many times more polluted than outdoor air. That’s because most buildings today are sealed tight to keep heated and cooled air from leaking out. Although this conserves energy, it can create indoor air that’s infested with invisible pollutants that adversely affect health and well-being. Keep the air quality in your Shaker Heights home as clean as possible with our top-rated indoor air quality services.
When you need indoor air quality services in Shaker Heights, there’s only one name you need to know—P.K. Wadsworth.
Choose P.K. Wadsworth As Your Shaker Heights HVAC Company
P.K. Wadsworth has one of the most experienced HVAC companies in Shaker Heights, Ohio. All of our heating and cooling professionals are trained and certified to work on most heating and air conditioning systems, regardless of the brand. From heating replacement to AC repair in Shaker Heights, you can trust our team to get the job done right.
Contact our local HVAC company to schedule heating or air conditioning services throughout Shaker Heights—including AC or furnace repair, HVAC replacement, and HVAC maintenance.
P.K. Wadsworth Heating, Cooling, Plumbing and Electric has completed 20 jobs in Shaker Heights, OH between January 2026 and February 2026. The most recent job was on February 3, 2026.Recent Jobs and Reviews in Shaker Heights, OH
Shaker Heights, OH at a glance
Job Locations and Reviews
Performed scheduled maintenance on Kenmore Power Miser water heater. Completed full inspection of tank, gas control valve, and all plumbing connections. All systems functioning properly with no issues identified.
Responded to intermittent no-heat complaint on first floor of residence with 6-9 year old furnace system. Conducted diagnostic testing including gas pressure measurements with manometer (7.47" WC) and electrical control circuit verification with multimeter. System was operational during visit, but performed comprehensive inspection to identify potential causes of intermittent failure for preventative maintenance.
Performed scheduled heating maintenance on residential furnace. Inspected control board and electrical connections, verifying all wiring was secure and properly connected. System is operating within normal parameters with no issues detected.
Performed maintenance on two heating systems. One furnace was non-operational due to Nest thermostat issues that may require replacement. The ground-mounted rooftop unit was serviced and temporarily restored to operation, though customer has requested a sales consultation regarding full system replacement.
Performed routine boiler maintenance service including comprehensive inspection of the Honeywell control system and associated piping components. Conducted combustion analysis using Testo 310 analyzer, confirming proper operation with readings of 20.2% O2 and 3% CO2. System left in good working condition with all safety parameters verified.
Completed routine heating system tune-up with comprehensive combustion analysis using Testo 310 analyzer, measuring CO2 levels at 18.7% and temperature at 124°. Inspected gas connections, flexible gas line, and associated fittings; all components found to be in serviceable condition with no leaks detected.
Conducted monthly maintenance on 6-year-old heating system per contract. Inspected ventilation components and performed combustion analysis with Testo 310, confirming proper O2 levels at 12.2% and verifying zero carbon monoxide emissions. All system components functioning within normal parameters.
Responded to emergency service call for a 20-year-old boiler with no heat. Diagnosed failed pilot assembly and corroded heat exchanger components. Replaced pilot assembly and performed system flush to remove mineral buildup in the radiant heating system, restoring heat to the residence.
Performed scheduled heating maintenance on two furnace systems. Inspected both units, noting oxidation on copper refrigerant line in second system that will need monitoring. All systems functioning properly with clean filters and proper electrical connections verified.
Performed routine maintenance on 24-year-old boiler system. Identified significant crack in boiler base causing active leakage. Documented condition with detailed photos showing internal components and evidence of water damage. Recommended full replacement of unit due to age and structural failure.
Completed installation of a GVD-8 boiler system in basement utility area. Installed new copper supply/return lines with proper connections to existing plumbing network. Mounted expansion tank and connected vent piping according to manufacturer specifications.
Replaced defective pilot assembly and control box on heating system. Removed old UTEC control module and installed new one, ensuring proper connection of all wiring including MV, MV/PV, PV, ground, and spark terminals. System is now operating within manufacturer specifications.
Replaced failed relief valve on glycol storage tank system. Corrective maintenance addressed heavily oxidized copper piping and compromised pressure safety component. New valve properly installed to restore system integrity and safety functionality.
Conducted site assessment for potential mini-split installation on 3rd floor. Examined two rooms with sloped ceilings - an exercise/recreational room and a child's playroom. Client is a returning customer who previously had mini-splits installed on 1st and 2nd floors approximately 3 years ago and requested options for extending system to the attic level.
Completed scheduled SPP maintenance tune-up on wall-mounted HVAC system. Inspected air handler unit mounted on concrete block wall, checking all connections including the blue valve component. Examined adjacent plumbing infrastructure including copper pipes and PVC installation. All components functioning properly with no issues detected.
Replaced deteriorated black iron pipe sections in utility area where significant corrosion was present at multiple connection points. Installed new piping with proper fittings and seals to address water damage risks and restore system integrity.
Inspected bathroom sink leak reported by customer. Visual inspection of plumbing connections revealed multiple metal pipes and braided stainless steel flexible supply lines in a confined installation space. No further action documented.
Successfully installed new furnace system in basement utility area. Unit features proper electrical connections with junction box and conduit, along with PVC drainage/ventilation piping. System includes appropriate ductwork connections with rectangular metal ducting extending to existing distribution network.
Performed courtesy inspection of water heater system and expansion tank. Checked all copper pipe connections, valves, and fittings for proper installation and functionality. Verified expansion tank mounting and pressure settings to ensure optimal operation of the system.
Responded to customer report of boiler leak. Upon inspection, identified significant oxidation and corrosion on copper supply lines and brass fittings, particularly at 90-degree elbow joints. System shows signs of age with extensive rusty orange patina development on multiple pipe sections that requires attention to prevent future leakage issues.