P.K. Wadsworth Heating & Cooling has kept Shaker Heights homeowners comfortable since 1936. We’re experts in climate control who have consistently earned the loyalty and trust of customers by exceeding expectations with best-in-class technicians, reliable service, and custom solutions.
Whether it’s through our preventative maintenance plans, installation of heating and cooling systems, or efficient and effective HVAC repair throughout Shaker Heights, our flexibility, professionalism, industry knowledge, and friendly staff have made all the difference for more than 80 years.
Contact our local HVAC company for repair, replacement, and maintenance services in the Shaker Heights, Ohio area.
Heating Services In Shaker Heights

P.K. Wadsworth is the leading HVAC company in Cleveland, providing heating services in Shaker Heights. From heating system repair to replacement, we’ll perform necessary tasks to keep your system in prime condition while providing you the peace of mind that your home heating is as reliable, safe and efficient as possible. P.K. Wadsworth offers the following heating services:
- Furnace installation
- Furnace replacement
- Furnace maintenance
- Furnace repair
- Boiler installation
- Boiler replacement
- Boiler maintenance
- Boiler repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
Contact us to schedule top-rated heating services, such as furnace repair, heating replacement, and heating installation in Shaker Heights!
Air Conditioning Services In Shaker Heights
With P.K. Wadsworth, an HVAC technician will assess your Shaker Heights home, budget, and comfort preferences. In order to keep you and your family comfortable—even when the temperatures are reaching record highs—we offer the following air conditioner services in Shaker Heights:
- Air conditioner installation
- Air conditioner replacement
- Air conditioner maintenance
- Air conditioner repair
- Ductless system installation
- Ductless system replacement
- Ductless system maintenance
- Ductless system repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
- Contact our local HVAC company to schedule air conditioner services, such as AC repair, replacement, and maintenance in Shaker Heights!
Indoor Air Quality In Shaker Heights, Ohio

Many people are surprised to learn that indoor air can be many times more polluted than outdoor air. That’s because most buildings today are sealed tight to keep heated and cooled air from leaking out. Although this conserves energy, it can create indoor air that’s infested with invisible pollutants that adversely affect health and well-being. Keep the air quality in your Shaker Heights home as clean as possible with our top-rated indoor air quality services.
When you need indoor air quality services in Shaker Heights, there’s only one name you need to know—P.K. Wadsworth.
Choose P.K. Wadsworth As Your Shaker Heights HVAC Company
P.K. Wadsworth has one of the most experienced HVAC companies in Shaker Heights, Ohio. All of our heating and cooling professionals are trained and certified to work on most heating and air conditioning systems, regardless of the brand. From heating replacement to AC repair in Shaker Heights, you can trust our team to get the job done right.
Contact our local HVAC company to schedule heating or air conditioning services throughout Shaker Heights—including AC or furnace repair, HVAC replacement, and HVAC maintenance.
P.K. Wadsworth Heating, Cooling, Plumbing and Electric has completed 20 jobs in Shaker Heights, OH in July 2026. The most recent job was on July 29, 2026.Recent Jobs and Reviews in Shaker Heights, OH
Shaker Heights, OH at a glance
Job Locations and Reviews
Completed warranty inspection on new HVAC installation. Verified proper installation of flexible ductwork at ceiling junction and confirmed escutcheon plate placement at floor register. All components meeting manufacturer specifications with no deficiencies noted.
Completed HVAC system estimate for equipment replacement in residential utility space with easy access conditions. Evaluated existing furnace unit with associated ductwork, refrigerant lines, condensate drainage system including P-trap configuration, and electrical connections. Documented current system components including air handler plenum, flexible ductwork, copper refrigerant piping, and PVC condensate drain assembly to provide comprehensive replacement options for aging equipment showing signs of wear.
Responded to service call for HVAC unit that was continuously running. Diagnosed and replaced failed low voltage components including control relays, freeze sensor, and water safety switch. Performed voltage testing at terminal block and verified proper amperage draw using clamp meter. Tested all control circuits and confirmed proper system operation with appropriate cycling upon completion of repairs.
# HVAC Cooling Maintenance Completed
Performed comprehensive preventive maintenance service on residential air conditioning system. Conducted thorough inspection of outdoor condensing unit, including examination of electrical components, capacitor, contactor, and wiring connections. All electrical connections were verified secure and in proper working condition. Replaced air filter with new pleated media filter to ensure optimal airflow and system efficiency. System operational testing confirmed proper cooling function with no deficiencies noted.
Completed routine cooling system maintenance as part of ongoing service plan. Performed comprehensive inspection of HVAC unit interior components, including capacitor, wiring connections, and control board functionality. Removed and inspected return air grille, ensuring proper airflow and system operation throughout the residential cooling system.
Completed routine HVAC tune-up on 1-year-old air handler/furnace system with no reported issues or symptoms. Replaced 16x20x1 Air Four Vmax-4-FC pleated air filter and verified proper installation within air handler compartment. Inspected outdoor electrical disconnect switch, confirmed proper operation and secure mounting, with all components in normal working condition showing no signs of damage or deterioration.
Performed routine maintenance flush on tanked water heater system. Drained sediment buildup from tank bottom through drain valve, refilled system, and verified proper water pressure at 60 PSI on gauge. Inspected copper supply lines and brass shutoff valve for leaks or corrosion—all connections secure with no active leaks detected.
Responded to callback regarding AC installation from previous year with reported electrical discrepancy. Upon arrival, verified electrical requirements and discovered improper amperage rating on circuit breaker - unit required 30-amp protection but was operating on 20-amp breaker, creating potential safety hazard and code violation. Performed comprehensive diagnostic testing using multimeter to verify capacitor function, voltage readings, and overall system operation. Documented existing electrical configuration and equipment specifications with photos. Confirmed customer's electrician findings were accurate regarding undersized breaker. System requires proper 30-amp circuit installation by licensed electrician before unit can be safely operated per manufacturer specifications and electrical code requirements.
Completed scheduled preventive maintenance on multiple cooling systems as part of ongoing service agreement. Performed comprehensive inspection of all HVAC units, including filter replacement on air handling systems. Removed heavily soiled air filters showing significant dust and debris accumulation and installed new high-efficiency pleated filters to restore proper airflow and system performance. Inspected and serviced mechanical components, including securing clips and mounting brackets to ensure proper equipment operation. Verified all systems operating within normal parameters upon completion of maintenance procedures.
# HVAC Cooling Maintenance - 10+ Years Old Unit
Performed comprehensive cooling maintenance on aging residential HVAC system located on exterior concrete pad. Conducted thorough inspection of electrical components, wiring connections, and internal systems with access panel removed for detailed assessment.
## Work Performed
Inspected all electrical wiring and terminal connections, including power supply wires, control wiring, and capacitor connections. Verified proper wire routing and secure connections throughout the electrical compartment. Examined capacitor for signs of bulging, leaking, or deterioration common in older units. Checked all wire terminals and connectors for corrosion, looseness, or heat damage.
Evaluated internal motor components and associated wiring harnesses. Inspected wire management and securing methods, ensuring proper strain relief and routing to prevent chafing or contact with moving parts. Assessed condition of electrical housing and framework for weatheri
Returned to site to complete scheduled maintenance work on HVAC system. Performed thorough coil wash on condenser unit to remove dust accumulation and debris from heat exchanger fins, restoring optimal airflow and heat transfer efficiency. Installed new pleated air filters to ensure proper system filtration and indoor air quality.
Completed quality check inspection of residential HVAC system consisting of dual-unit configuration with air handler and furnace installed in utility closet. Photographically documented equipment condition, installation integrity, proper PVC drainage/ventilation line routing, electrical connections, and verified adequate clearances meet code requirements—all components found in normal operating condition.
Completed comprehensive cooling system tune-up on residential HVAC unit. Performed thorough inspection of furnace interior components, blower motor assembly, electrical connections, and control board wiring. Conducted diagnostic testing of system operations and verified proper functionality of all mechanical and electrical components.
Performed comprehensive HVAC cooling system maintenance under MVP program. Conducted electrical diagnostics using True RMS power clamp meter, measuring amperage draw on compressor/condenser fan motor at 0.13A and line voltage at 249.6V to verify proper system operation and load characteristics. All measurements within normal operating parameters, confirming system functionality and electrical efficiency.
Completed cooling season tune-up on ductless mini-split system. Performed standard maintenance inspection, verified system operation, and recorded supply air temperature of 73.3°F to confirm proper cooling performance.
Returned to complete compressor replacement on air conditioning system. Successfully installed new compressor unit, evacuated and recharged system to manufacturer specifications, and verified proper operation with manifold gauges showing appropriate pressures and temperatures. System tested and left in full working order.
Completed scheduled preventive maintenance visit on residential cooling system. Performed thorough inspection of evaporator coil assembly located in attic space, noting normal operational wear with minor dust accumulation on aluminum fins. Verified electrical parameters using digital multimeter, confirming system operating within manufacturer specifications. All components functioning properly with no immediate service needs identified.
Responded to no AC call and performed electrical inspection of HVAC system in attic mechanical space. Documented Daikin unit installation, including electrical connections, copper refrigerant lines, and filter housing, with photos taken for reference. Coordinated building access and completed visual assessment of electrical components as requested by HVAC technician.
Completed scheduled cooling system maintenance on outdoor HVAC condenser unit. Performed thorough inspection of condenser coil assembly, which revealed significant accumulation of dirt, dust, and organic debris between aluminum fins. Cleaned condenser coils to restore proper airflow and heat transfer efficiency. Verified protective metal grille structural integrity and confirmed unit operational status upon completion.
Completed scheduled preventive maintenance on residential Daikin air conditioning system. Performed comprehensive system inspection including electrical measurements with digital clamp meter, verified proper amperage draw, and confirmed unit operation. Condenser unit found in good condition with clean coils, proper clearances maintained, and secure mounting on concrete pad.