P.K. Wadsworth Heating & Cooling has kept Shaker Heights homeowners comfortable since 1936. We’re experts in climate control who have consistently earned the loyalty and trust of customers by exceeding expectations with best-in-class technicians, reliable service, and custom solutions.
Whether it’s through our preventative maintenance plans, installation of heating and cooling systems, or efficient and effective HVAC repair throughout Shaker Heights, our flexibility, professionalism, industry knowledge, and friendly staff have made all the difference for more than 80 years.
Contact our local HVAC company for repair, replacement, and maintenance services in the Shaker Heights, Ohio area.
Heating Services In Shaker Heights

P.K. Wadsworth is the leading HVAC company in Cleveland, providing heating services in Shaker Heights. From heating system repair to replacement, we’ll perform necessary tasks to keep your system in prime condition while providing you the peace of mind that your home heating is as reliable, safe and efficient as possible. P.K. Wadsworth offers the following heating services:
- Furnace installation
- Furnace replacement
- Furnace maintenance
- Furnace repair
- Boiler installation
- Boiler replacement
- Boiler maintenance
- Boiler repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
Contact us to schedule top-rated heating services, such as furnace repair, heating replacement, and heating installation in Shaker Heights!
Air Conditioning Services In Shaker Heights
With P.K. Wadsworth, an HVAC technician will assess your Shaker Heights home, budget, and comfort preferences. In order to keep you and your family comfortable—even when the temperatures are reaching record highs—we offer the following air conditioner services in Shaker Heights:
- Air conditioner installation
- Air conditioner replacement
- Air conditioner maintenance
- Air conditioner repair
- Ductless system installation
- Ductless system replacement
- Ductless system maintenance
- Ductless system repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
- Contact our local HVAC company to schedule air conditioner services, such as AC repair, replacement, and maintenance in Shaker Heights!
Indoor Air Quality In Shaker Heights, Ohio

Many people are surprised to learn that indoor air can be many times more polluted than outdoor air. That’s because most buildings today are sealed tight to keep heated and cooled air from leaking out. Although this conserves energy, it can create indoor air that’s infested with invisible pollutants that adversely affect health and well-being. Keep the air quality in your Shaker Heights home as clean as possible with our top-rated indoor air quality services.
When you need indoor air quality services in Shaker Heights, there’s only one name you need to know—P.K. Wadsworth.
Choose P.K. Wadsworth As Your Shaker Heights HVAC Company
P.K. Wadsworth has one of the most experienced HVAC companies in Shaker Heights, Ohio. All of our heating and cooling professionals are trained and certified to work on most heating and air conditioning systems, regardless of the brand. From heating replacement to AC repair in Shaker Heights, you can trust our team to get the job done right.
Contact our local HVAC company to schedule heating or air conditioning services throughout Shaker Heights—including AC or furnace repair, HVAC replacement, and HVAC maintenance.
P.K. Wadsworth Heating, Cooling, Plumbing and Electric has completed 20 jobs in Shaker Heights, OH in July 2026. The most recent job was on July 23, 2026.Recent Jobs and Reviews in Shaker Heights, OH
Shaker Heights, OH at a glance
Job Locations and Reviews
Completed routine cooling system maintenance on residential HVAC unit. Performed standard inspection of furnace and air handler components, replaced heavily soiled air filter with new pleated filter, and verified proper operation of Space-Gard air cleaner system. All equipment found in functional condition with no issues identified.
Completed comprehensive cooling system tune-up and performance evaluation. Measured and recorded operating amperage at 70.52A using calibrated clamp meter, verified electrical parameters within manufacturer specifications, and inspected condenser unit components. Noted potential corrosion concerns on exterior cabinet panels requiring future monitoring.
Completed comprehensive preventive maintenance on aging residential cooling system. Inspected thermal expansion valve (TXV) assembly and refrigerant lines, verifying proper operation of the metering device and sensing bulb. Performed electrical diagnostics using digital multimeter to confirm system voltage and amperage readings were within manufacturer specifications.
Completed cooling system tune-up during scheduled maintenance window. Performed standard inspection of furnace unit and ductwork system, noting significant condensation present on insulated supply duct in attic space, indicating possible insulation degradation or excessive humidity levels. Documented equipment condition with photos for customer records and verified all accessible system components and connections.
Conducted on-site assessment for boiler replacement and Unico system installation for indoor HVAC components. Evaluated existing gas valve assembly, control mechanisms, and wiring connections on current heating equipment, documenting equipment condition and spatial requirements for new system installation. Prepared comprehensive quote documentation for boiler replacement and indoor air distribution system upgrade.
Completed routine HVAC cooling system maintenance in attic installation. Performed standard inspection of air handler unit, ductwork connections, and associated components including condensate management system. All equipment found in proper working condition with no issues identified during service visit.
Completed scheduled preventive maintenance on residential cooling system. Performed electrical diagnostics using clamp meter, recording amperage readings of 40.21A and 13.75A to verify proper compressor and system operation. Accessed unit control panel to inspect wiring connections and CoreSense diagnostic module for Copeland compressor system, confirming all electrical components functioning within normal parameters.
Completed comprehensive cooling season tune-up on two HVAC systems. Performed standard maintenance procedures including inspection of the LincUp system components, verified proper operation of shut-off valves and PVC condensate drain lines, measured supply air temperature at 61.5°F confirming adequate cooling performance, and inspected all accessible equipment for proper operation and safety compliance.
Completed routine cooling system maintenance as part of recurring service plan. Performed comprehensive inspection of air distribution system, including ventilation grilles and return air pathways, noting minor dust accumulation on vent covers. Accessed attic space to inspect HVAC ductwork and insulation integrity. Evaluated flexible duct runs for proper installation and airflow efficiency. Conducted temperature differential measurements using digital instrumentation across insulation and air distribution components to verify system performance. Confirmed adequate insulation levels and proper vapor barrier installation surrounding ductwork. System operating within normal parameters with no immediate service concerns identified.
Responded to no cooling call on residential HVAC system. Arrived on-site and performed diagnostic evaluation of outdoor condensing unit and air handler assembly. System inspection completed with photographic documentation of equipment condition and installation setup.
Completed installation and system startup of Unico HVAC system in residential basement, including furnace and air handler with insulated ductwork and condensate drainage. All units tested and verified operational, with proper electrical connections and airflow confirmed throughout the system.
Completed startup and commissioning of Unico air handler system installation. System accessed through floor openings in hallway and kitchen areas, with ductwork routing requiring structural floor modifications to accommodate compact high-velocity distribution system. Verified proper airflow through floor registers, confirmed all connections secure, and validated system operation per manufacturer specifications.
Responded to service call for loud whirring sound occurring at system startup on an 11-year-old air conditioning unit. Upon arrival, performed diagnostic inspection of outdoor condensing unit and associated electrical components. Inspected condenser fan motor, capacitor, and contactor assembly for signs of wear or failure that could cause the reported noise. Examined exterior electrical junction box and verified all wire connections were secure and properly terminated. Assessed ductwork seams and insulation for any loose components or vibration points that might contribute to startup noise. Documented equipment condition with photographs showing electrical connections at outdoor unit and ductwork installation. Based on the age of the system and symptom presentation, likely causes include worn condenser fan motor bearings, failing start capacitor, or loose mounting hardware creating vibration during initial startup cycle.
# HVAC Cooling System Maintenance - MVP Service
Performed comprehensive preventive maintenance on an aging outdoor cooling system unit. Conducted thorough inspection of electrical components housed within the exterior-mounted control panel, including the MARS capacitor and Homeis HN51KC024 contactor.
Evaluated all electrical connections and wiring integrity, noting age-appropriate wear on conductor insulation. Verified proper terminal connections on the 24VAC coil contactor and capacitor assembly. Assessed mounting hardware and panel condition, which showed expected weathering consistent with outdoor installation and extended service life.
All critical electrical components were inspected and found to be operational. System electrical connections were secure and functioning within normal parameters. Unit cleared for continued operation following maintenance protocol completion.
Completed installation of new Goodman air conditioning system including outdoor condensing unit positioned on concrete pad against building exterior. Installed metal conduit line set connecting outdoor unit to existing indoor air handler, with all electrical connections properly terminated and secured to building structure. System tested and confirmed operational upon completion.
Completed comprehensive cooling system maintenance on residential HVAC unit. Performed inspection of electrical components including capacitor, contactor assembly, and all associated wiring connections to ensure proper operation and system reliability. All components found to be functioning within normal parameters and unit left in good working condition.
Conducted comprehensive electrical estimate for fixture replacement and potential rewiring project at 90-year-old residential property. Assessed exterior light fixtures at back door location requiring replacement, with customer-supplied parts available for installation. Documented existing electrical infrastructure including aged circuit breaker panel with handwritten circuit labels and multiple conduit entries, identifying need for consultation regarding partial home rewiring due to age of electrical system. Photographed current conditions of electrical panel mounted in unfinished basement area and interior lighting fixtures to support estimate preparation and future scope of work planning.
Completed comprehensive electrical inspection of residential property with focus on existing electrical panel and outdated knob-and-tube wiring system. Documented current panel configuration featuring dual-row circuit breaker arrangement with yellow main disconnect switches and assessed overall electrical distribution system condition. Identified safety concerns with existing knob-and-tube wiring and problematic outlet conditions requiring attention. Provided detailed assessment and recommendations for panel upgrade to meet current electrical code requirements and address potential hazards associated with obsolete wiring methods.
Installed whole home surge protection system at main electrical panel to safeguard residence from voltage spikes and power surges. Mounted surge protective device with monitoring capability, verified proper grounding connections, and confirmed operational status through illuminated indicator light.
Completed scheduled preventive maintenance on attic-mounted air handler unit as part of ongoing cooling system service plan. Inspected and serviced HVAC equipment including air handler, condensate pump assembly, and associated drainage lines. All components found operating within normal parameters with condensate pump actively functioning and drainage system clear of obstructions.