P.K. Wadsworth Heating & Cooling has kept Shaker Heights homeowners comfortable since 1936. We’re experts in climate control who have consistently earned the loyalty and trust of customers by exceeding expectations with best-in-class technicians, reliable service, and custom solutions.
Whether it’s through our preventative maintenance plans, installation of heating and cooling systems, or efficient and effective HVAC repair throughout Shaker Heights, our flexibility, professionalism, industry knowledge, and friendly staff have made all the difference for more than 80 years.
Contact our local HVAC company for repair, replacement, and maintenance services in the Shaker Heights, Ohio area.
Heating Services In Shaker Heights

P.K. Wadsworth is the leading HVAC company in Cleveland, providing heating services in Shaker Heights. From heating system repair to replacement, we’ll perform necessary tasks to keep your system in prime condition while providing you the peace of mind that your home heating is as reliable, safe and efficient as possible. P.K. Wadsworth offers the following heating services:
- Furnace installation
- Furnace replacement
- Furnace maintenance
- Furnace repair
- Boiler installation
- Boiler replacement
- Boiler maintenance
- Boiler repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
Contact us to schedule top-rated heating services, such as furnace repair, heating replacement, and heating installation in Shaker Heights!
Air Conditioning Services In Shaker Heights
With P.K. Wadsworth, an HVAC technician will assess your Shaker Heights home, budget, and comfort preferences. In order to keep you and your family comfortable—even when the temperatures are reaching record highs—we offer the following air conditioner services in Shaker Heights:
- Air conditioner installation
- Air conditioner replacement
- Air conditioner maintenance
- Air conditioner repair
- Ductless system installation
- Ductless system replacement
- Ductless system maintenance
- Ductless system repair
- Heat pump installation
- Heat pump replacement
- Heat pump maintenance
- Heat pump repair
- Contact our local HVAC company to schedule air conditioner services, such as AC repair, replacement, and maintenance in Shaker Heights!
Indoor Air Quality In Shaker Heights, Ohio

Many people are surprised to learn that indoor air can be many times more polluted than outdoor air. That’s because most buildings today are sealed tight to keep heated and cooled air from leaking out. Although this conserves energy, it can create indoor air that’s infested with invisible pollutants that adversely affect health and well-being. Keep the air quality in your Shaker Heights home as clean as possible with our top-rated indoor air quality services.
When you need indoor air quality services in Shaker Heights, there’s only one name you need to know—P.K. Wadsworth.
Choose P.K. Wadsworth As Your Shaker Heights HVAC Company
P.K. Wadsworth has one of the most experienced HVAC companies in Shaker Heights, Ohio. All of our heating and cooling professionals are trained and certified to work on most heating and air conditioning systems, regardless of the brand. From heating replacement to AC repair in Shaker Heights, you can trust our team to get the job done right.
Contact our local HVAC company to schedule heating or air conditioning services throughout Shaker Heights—including AC or furnace repair, HVAC replacement, and HVAC maintenance.
P.K. Wadsworth Heating, Cooling, Plumbing and Electric has completed 20 jobs in Shaker Heights, OH in April 2026. The most recent job was on April 20, 2026.Recent Jobs and Reviews in Shaker Heights, OH
Shaker Heights, OH at a glance
Job Locations and Reviews
Returned to complete maintenance service on residential HVAC system as requested. Replaced air filters on furnace unit, reset humidifier control panel to proper settings, and closed supply vents per customer specifications. System inspected and confirmed operational, with all requested adjustments completed during this follow-up visit.
Completed scheduled maintenance on wall-mounted tankless water heater, performing thorough flush and descaling procedure to remove mineral buildup from heat exchanger and internal components. Inspected all water supply connections, gas lines, electrical connections, and venting system; verified proper operation of unit with all components functioning within manufacturer specifications.
Performed routine maintenance flush on tanked water heater system to remove sediment buildup and ensure optimal performance. Inspected water heater controls, temperature settings, and safety mechanisms, confirming all components were functioning properly and unit was operating within normal parameters.
Responded to service call for air conditioning system failing to cool residence below 73 degrees. Upon arrival, performed diagnostic evaluation of outdoor condenser unit and electrical components. Utilized digital clamp meter to measure amperage and voltage at contactor, confirming proper electrical supply to unit. Inspected condenser for mechanical issues, refrigerant levels, and airflow restrictions. Unit found operational during testing with all electrical readings within manufacturer specifications.
Performed comprehensive AC system evaluation for customer experiencing no cooling condition. Previous service by another company had been unsuccessful. Conducted detailed assessment of existing outdoor HVAC unit and associated components, including refrigerant line routing and equipment placement. Documented measurements and existing installation configuration to provide accurate replacement options. Evaluated water heater proximity and mechanical room constraints to ensure proper clearances and access for new equipment installation.
Completed full HVAC system installation including 96% efficiency furnace, air conditioning unit, and humidifier. Installed Amana outdoor condensing unit on concrete pad with proper electrical disconnect and conduit routing, established all refrigerant line connections, and verified system operation at manufacturer specifications.
Completed comprehensive air conditioning maintenance and tune-up on residential HVAC system with air handler located in attic space. Performed standard preventive maintenance procedures including filter inspection, system operation verification, and visual equipment assessment. Unit operational with 3M Filtrete filters properly staged for replacement, condensate pump and drain pan functioning correctly, and all electrical connections secure.
Performed scheduled cooling maintenance on 5-ton air conditioning unit covered under service protection plan. Conducted comprehensive system inspection including electrical connections, refrigerant lines, and operational diagnostics using calibrated testing equipment. All refrigerant line insulation and electrical terminations were verified to be secure and in proper working condition, with system measurements indicating normal operating parameters.
Returned to address garage door opener issue from previous service visit. Inspected Linear brand garage door opener installation, verified proper mounting to ceiling joists, and checked electrical connections and wiring routing. Tested opener operation and manual release mechanism to ensure system functioning correctly. Resolved previous concern and confirmed garage door opener operating as intended.
Replaced contaminated blower wheel assembly in air handler unit due to excessive dust and debris accumulation affecting system performance. Removed heavily soiled squirrel-cage blower wheel and installed new assembly, restoring proper airflow and operational efficiency to the HVAC system.
Completed annual preventative maintenance inspection on steam boiler system. Inspected and documented electrical control components, circulator pump assembly with brass fittings, low-voltage wiring connections, and associated mechanical equipment. All system components found operating within normal parameters, with proper electrical connections secured and equipment functioning as designed.
# HVAC Boiler Heating Maintenance
Performed comprehensive heating maintenance on boiler system located in mechanical room. Inspected primary boiler unit, a blue metal cabinet-style heating system with associated motorized components and control assemblies. Examined actuator motor assembly manufactured in Taiwan (Model C20 B2) mounted on bracket with proper hardware connections. Verified electrical connections and wiring integrity throughout system, including control circuits and power supply connections. Checked flexible metal vent connector for proper installation and secure attachment. Assessed overall system operation and component condition. Unit showed normal wear patterns consistent with regular operation. All mechanical and electrical components functioning within normal parameters at time of inspection.
Completed full HVAC system installation including rooftop unit (RTU) air conditioning system, furnace, and ductwork with liner. Protected all interior floors and stairways throughout the installation process per protocol. Performed final electrical verification and amperage testing using clamp meter to ensure proper system operation and compliance with specifications.
Inspected recently installed electrical panel and verified breaker connections and functionality. Performed voltage testing with digital multimeter to confirm proper circuit operation and ensure the breaker feeding the panel was functioning correctly per specifications.
Completed first-year maintenance on two ductless heat pump systems. Performed standard preventive maintenance procedures on both indoor wall-mounted units and outdoor condensers, including inspection of refrigerant line sets, electrical connections, and drainage systems. All components found operating within normal parameters with no deficiencies noted.
Completed first-year cooling system maintenance on residential outdoor condensing unit. Performed comprehensive system inspection, tested electrical connections and refrigerant pressures using diagnostic instruments, verified proper fan operation, and confirmed unit specifications. All components operating within normal parameters with no issues identified.
Performed preventive maintenance on two cooling systems, inspecting both the outdoor condensing unit and indoor air handler. Verified refrigerant line connections, service valves, and electrical components were secure and functioning properly, with all equipment operational at time of departure.
Responded to service call for newly installed Unico system experiencing intermittent cooling operation with repeated shutdowns. Performed diagnostic inspection of outdoor condensing unit and internal components, verified condenser coil condition and airflow pathways were clear and unobstructed. System components appeared properly installed with no visible damage to coils or protective grilles.
Completed comprehensive cooling system tune-up on split HVAC system. Performed thorough inspection of outdoor condensing unit, verifying proper operation of dual capacitors, contactor, and all electrical connections. Checked indoor portable cooling equipment, confirmed proper power supply and operational status of all components for optimal system performance.
Performed routine maintenance flush on Bradford White tanked water heater unit. Drained sediment buildup from tank bottom, cleared mineral deposits, and verified proper operation of temperature-pressure relief valve. Inspected all copper and galvanized piping connections, shut-off valves, and fittings for leaks or corrosion—all found secure and functioning properly. System refilled, tested, and returned to normal operation.